| Parameter | Value |
|---|---|
| 48 V DC | |
| Type | free cable end |
| Coding | A |
| Shielded | no |
| Cable type | PUR halogen-free black [PUR] |
| Application | Mobile hydraulics |
| Coding type | A |
| Cable length | 10 m |
| Cable weight | 42 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Locking type | Clip locking |
| Product type | Sensor/actuator cable |
| Test voltage | ≥ 3000 V AC (Spark test) |
| UL AWM Style | 20549 / 10152 (80°C/300 V) |
| Overall twist | 3 wires, twisted |
| Seal material | Silicon |
| Status display | no |
| AWG signal line | 18 |
| Contact material | Cu alloy |
| Flame resistance | according to UL 758/1581 (horizontal) |
| Other resistance | hydrolysis and microbe resistant |
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C |
| Conductor material | Bare Cu litz wires |
| Nominal current IN | 8 A |
| Nominal voltage UN | 48 V AC |
| Single wire, color | brown, blue, black |
| Special properties | flexible |
| Dimensional drawing | |
| Number of positions | 3 |
| Degree of protection | IP67 |
| No. of cable outlets | 1 |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | TPU |
| Thickness, insulation | ≥ 0.21 mm |
| External sheath, color | black-gray RAL 7021 |
| Nominal voltage, cable | ≤ 300 V AC |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 3x 0.75 mm² (Signal line) |
| External cable diameter | 5.20 mm ±0.15 mm |
| Thickness, outer sheath | ≥ 0.38 mm |
| Contact carrier material | PA 6.6 |
| Contact surface material | nickel-plated |
| Material wire insulation | PP |
| Max. conductor resistance | ≤ 26 Ω/km (at 20 °C) |
| Material for screw connection | not available |
| Wire diameter incl. insulation | 1.69 mm ±0.05 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 42x 0.15 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 4000000, Bending radius: 48 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² |
| Flammability rating according to UL 94 | V2 |
| Minimum bending radius, fixed installation | 5 x D |
| Smallest bending radius, fixed installation | 26 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 52 mm |
Technical specifications and performance data