Service time: Monday to Friday 9:00-18:00
SAC-3P-10,0-800/M 8FS - SAC-3P-10,0-800/M 8FS 1417674 PHOENIX CONTACT Sensor/actuator cable SAC-3P-10,0-800/M 8FS 1417674
In Stock Hot Product

SAC-3P-10,0-800/M 8FS

SAC-3P-10,0-800/M 8FS 1417674 PHOENIX CONTACT Sensor/actuator cable SAC-3P-10,0-800/M 8FS 1417674

$0.00USD
4301 in stock
Key Specifications
GTIN:4055626119755
(Cable):No hazardous substances above threshold values
Orderkey:1417674
Packing unit:1
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626119755
(Cable)No hazardous substances above threshold values
Orderkey1417674
Packing unit1
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Environmentally friendly use period: unlimited = EFUP-e
UNSPSC 13.2 (ETIM)31251501
Custom tariff number85444290
(Ambient conditions)60 V DC
Contact material (General)CuSn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
Torque (Ambient conditions)0.2 Nm (M8 connectors)
(Standards and Regulations)to 120 °C (for 3000 h)
eCl@ss 5.1 (Classifications)27061801
eCl@ss 6.0 (Classifications)27279200
eCl@ss 7.0 (Classifications)27279218
eCl@ss 8.0 (Classifications)27279218
eCl@ss 9.0 (Classifications)27060311
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)M8 connector
Note (Standards and Regulations)Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments.
Standards/regulations (Material)IEC 61076-2-104
Contact carrier material (General)TPU GF
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)48 V AC
Status display (Ambient conditions)No
Length of cable (Key Commercial Data)10 m
Cable type (Standards and Regulations)Gray, highly flexible PUR
Wire colors (Standards and Regulations)brown, blue, black
Acceleration (Standards and Regulations)30 m/s²
Cable weight (Standards and Regulations)24 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)in accordance with DIN VDE 0472 part 815
Number of positions (Ambient conditions)3
UL AWM style (Standards and Regulations)20233
Overall twist (Standards and Regulations)3 wires, twisted
Overvoltage category (Ambient conditions)II
Torsion force (Standards and Regulations)± 360 °/m (1 000 000 torsion cycles)
Bending radius (Standards and Regulations)50 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M8 connector IEC 61076-2-104
AWG signal line (Standards and Regulations)24
Rated current at 40°C (Ambient conditions)4 A
Traversing path (Standards and Regulations)0.9 m
Traversing rate (Standards and Regulations)5 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 90 °C (Plug / socket)
Flame resistance (Standards and Regulations)according to IEC 60332-1-2
Other resistance (Standards and Regulations)Highly resistant to acids, alkaline solutions and solvents
Resistance to oil (Standards and Regulations)According to HD 22.10
Cable abbreviation (Standards and Regulations)Li12YYTPE-HF
Conductor material (Standards and Regulations)Bare Cu litz wires
Special properties (Standards and Regulations)Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing
Test voltage, cable (Standards and Regulations)2000 V
Conductor resistance (Standards and Regulations)approx. 76 Ω/km
Flammability rating according to UL 94 (General)HB
Insertion/withdrawal cycles (Ambient conditions)≥ 100
Flammability rating according to UL 94 (Material)HB
Insulation resistance (Standards and Regulations)≥ 20 MΩ*km
Protective circuit/component (Ambient conditions)unwired
External sheath, color (Standards and Regulations)gray RAL 7001
Nominal voltage, cable (Standards and Regulations)300 V
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)3x 0.25 mm² (Signal line)
Number of bending cycles (Standards and Regulations)15000000
Cable type (abbreviation) (Standards and Regulations)800
External cable diameter D (Standards and Regulations)4.3 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PES
Ambient temperature (operation) (Standards and Regulations)-40 °C ... 90 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)32x 0.10 mm
Core diameter including insulation (Standards and Regulations)1.2 mm ±0.05 mm (Signal line)
Minimum bending radius, fixed installation (Standards and Regulations)4 x D
Minimum bending radius, flexible installation (Standards and Regulations)7.5 x D
Minimum bending radius, drag chain applications (Standards and Regulations)7,5 x D

Product Description

Sensor/actuator cable, 3-pole, halogen-free, solder-resistant, solder-resistant, highly flexible, grey RAL 7001, free cable end, to M8 straight connection female, cable length: 10 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Sensor/actuator cable, 3-position, PUR halogen-free, resistant to welding sparks, highly flexible, gray RAL 7001, free cable end, on Socket straight M8, cable length: 10 m