| Parameter | Value |
|---|---|
| GTIN | 4055626142029 |
| Orderkey | 1418627 |
| Packing unit | 1 |
| (Dimensions) | 24 V DC |
| ETIM 5.0 (eCl@ss) | EC001855 |
| ETIM 6.0 (eCl@ss) | EC001855 |
| ETIM 7.0 (eCl@ss) | EC001855 |
| UNSPSC 13.2 (ETIM) | 31251501 |
| Custom tariff number | 85444290 |
| Rated voltage (Dimensions) | 24 V DC |
| Sealing material (General) | TPU (Seal molded) |
| Status display (Dimensions) | 1 LED |
| (Standards and Regulations) | -20 °C ... 80 °C (cable, flexible installation) |
| eCl@ss 5.1 (Classifications) | 27061801 |
| eCl@ss 6.0 (Classifications) | 27279200 |
| eCl@ss 7.0 (Classifications) | 27279218 |
| eCl@ss 8.0 (Classifications) | 27279218 |
| eCl@ss 9.0 (Classifications) | 27060311 |
| Standard designation (Material) | Valve connector |
| Degree of pollution (Dimensions) | 3 |
| Number of positions (Dimensions) | 3 |
| Standards/regulations (Material) | EN 175301-803 |
| Overvoltage category (Dimensions) | III |
| Standards/regulations (Dimensions) | Valve connector EN 175301-803 |
| Rated current at 40°C (Dimensions) | 2 A |
| Length of cable (Key Commercial Data) | 10 m |
| Material housing valve plug (General) | TPU |
| Valve plug contact material (General) | CuSn |
| Cable type (Standards and Regulations) | PUR black |
| Wire colors (Standards and Regulations) | black 1, black 2, green/yellow |
| Acceleration (Standards and Regulations) | 10 m/s² |
| UL AWM style (Standards and Regulations) | 20549 |
| Overall twist (Standards and Regulations) | 3 wires, twisted |
| Protective circuit/component (Dimensions) | Damping diode |
| AWG signal line (Standards and Regulations) | 17 |
| Traversing rate (Standards and Regulations) | 2.5 m/s |
| Flame resistance (Standards and Regulations) | DIN VDE 0482 |
| Other resistance (Standards and Regulations) | Low adhesion |
| Valve plug contact insert material (General) | PA 6.6 |
| Resistance to oil (Standards and Regulations) | largely oil-resistant |
| Valve plug contact surface material (General) | Sn |
| Cable abbreviation (Standards and Regulations) | Li9Y11Y |
| Conductor material (Standards and Regulations) | Bare Cu litz wires |
| Special properties (Standards and Regulations) | highly flexible |
| Test voltage, cable (Standards and Regulations) | 1200 V |
| Conductor resistance (Standards and Regulations) | 19.5 Ω/km (at 20 °C) |
| Flammability rating according to UL 94 (General) | V0 |
| Flammability rating according to UL 94 (Material) | V0 |
| Insulation resistance (Standards and Regulations) | ≥ 20 MΩ*km |
| External sheath, color (Standards and Regulations) | black RAL 9005 |
| Nominal voltage, cable (Standards and Regulations) | 300 V |
| Outer sheath, material (Standards and Regulations) | PUR |
| Conductor cross section (Standards and Regulations) | 3x 1 mm² |
| Number of bending cycles (Standards and Regulations) | 3000000 |
| Cable type (abbreviation) (Standards and Regulations) | 121 |
| External cable diameter D (Standards and Regulations) | 6 mm ±0.2 mm |
| Material conductor insulation (Standards and Regulations) | PP |
| Ambient temperature (operation) (Standards and Regulations) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line (Standards and Regulations) | 32x 0.20 mm |
| Core diameter including insulation (Standards and Regulations) | 2.1 mm ±0.05 mm |
| Minimum bending radius, flexible installation (Standards and Regulations) | 7.5 x D |
Technical specifications and performance data