| Parameter | Value |
|---|---|
| 60 V DC | |
| Type | Plug straight M12 |
| Coding | B |
| Shielded | yes |
| Bus system | PROFIBUS |
| Cable type | PROFIBUS [910] |
| Coding type | B (inverse) |
| Sensor type | PROFIBUS |
| Cable length | 20 m |
| Cable weight | 90 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Data cable preassembled |
| UL AWM Style | 21198 (80°C/300 V) |
| Overall twist | 2 cores with 2 fillers to the core |
| Seal material | NBR |
| Cable capacity | nom. 30 pF/m |
| Status display | no |
| Wave impedance | 150 Ω ±10 % (3 MHz ... 20 MHz) |
| AWG signal line | 24 |
| Article revision | 10 |
| Contact material | CuSn |
| Flame resistance | UL 1581, Section 1060 and UL 2556, Section 9.3 (FT1) |
| Material, filler | PP |
| Other resistance | Low adhesion |
| Conductor material | Tin-plated Cu litz wires |
| Nominal current IN | 4 A |
| Nominal voltage UN | 48 V AC |
| Shield attenuation | ≤ 0.049 dB/m (at 16 MHz) |
| Single wire, color | red, green |
| Conductor structure | 1x2xAWG24/19 |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 2 |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Signal type/category | PROFIBUS |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| External sheath, color | red lilac RAL 4001 |
| Nominal voltage, cable | 300 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Test voltage Core/Core | 1500 V (50 Hz, 1 min.) |
| Conductor cross section | 2x 0.25 mm² (Signal line) |
| External cable diameter | 7.80 mm ±0.2 mm |
| Optical shield covering | 85 % |
| Contact carrier material | PA 6.6 |
| Contact surface material | Ni/Au |
| Material wire insulation | Foam-Skin PP |
| Test voltage Core/Shield | 1500.00 V (50 Hz, 1 min.) |
| Max. conductor resistance | ≤ 78.6 Ω/km |
| Insertion/withdrawal cycles | ≥ 100 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 2.55 mm ±0.07 mm |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 19x 0.13 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 4000000, Bending radius: 65 mm, Traversing path: 4.5 m, Traversing rate: 3 m/s, Acceleration: 3 m/s², Ambient temperature: -20 °C ... 60 °C |
| Flammability rating according to UL 94 | V0 |
| Smallest bending radius, fixed installation | 40 mm |
| Smallest bending radius, movable installation | 65 mm |