Service time: Monday to Friday 9:00-18:00
SAC-2P-DTMS/0,3PUR/M12FS4P SKF - SAC-2P-DTMS/0,3PUR/M12FS4P SKF 1426044 PHOENIX CONTACT Cable for sensors/actuators SAC-2P-DTMS/0,3 PUR/M12FS..
In Stock Hot Product

SAC-2P-DTMS/0,3PUR/M12FS4P SKF

SAC-2P-DTMS/0,3PUR/M12FS4P SKF 1426044 PHOENIX CONTACT Cable for sensors/actuators SAC-2P-DTMS/0,3 PUR/M12FS..

$0.00USD
4960 in stock
Key Specifications
EAN:Four trillion fifty five billion six hundred twenty six million four hundred thirty seven thousand eight hundred fifty nine
(Cable):No dangerous substances above the thresholds
Key order:One million four hundred twenty six thousand forty four
(Material):little adherent
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
EANFour trillion fifty five billion six hundred twenty six million four hundred thirty seven thousand eight hundred fifty nine
(Cable)No dangerous substances above the thresholds
Key orderOne million four hundred twenty six thousand forty four
(Material)little adherent
Key sellingBF1DWA -
Packing unit1 pcs
ETIM 5.0 (eCl@ss)EC001855
ETIM 6.0 (eCl@ss)EC001855
ETIM 7.0 (eCl@ss)EC001855
China RoHS (Cable)Space of time for the intended use: unlimited = FEUP-e
Tariff number tariffEighty five million four hundred forty four thousand two hundred ninety
eCl@ss 6.0 (Ratings)Twenty seven million two hundred seventy nine thousand two hundred
eCl@ss 7.0 (Ratings)Twenty seven million two hundred seventy nine thousand two hundred eighteen
eCl@ss 9.0 (Ratings)Twenty seven million sixty thousand three hundred eleven
Oil resistance (Material)according to DIN en 60811-2-1, 168 h at 100 °C
Other resistors (Material)resistant to hydrolysis and microbes
(Environmental conditions)48 V DC
Flame resistance (Material)according to UL 758/1581 (horizontal)
Material contact (Overview)CuSn
Material knurled (Overview)Die-cast zinc, nickel plated
Absence of halogen (Material)according to DIN VDE 0472 part 815
Material body grip (Overview)TPU fire-retardant, self-extinguishing
Cable length (Data commercial)0.3 m
(Standards and specifications)-25 °C ... 80 °C (cable, available mobile)
Material of the board (Overview)Silicone
Unit weight (excluding packaging)35,200 g
Encoding (Environmental conditions)A - standard
Material contact surface (Overview)Ni/Au
Room temperature (service) (Measures)-20 °C ... 80 °C (male / female)
Material support of contacts (Overview)TPU GF
Tension sizing (Environmental conditions)48 V AC
Number of poles (Environmental conditions)Two
Acceleration (Standards and specifications)10 m/s2
Material contact valve connector (Overview)Cu alloy
Material housing valve connector (Overview)PA
UL AWM Style (Standards and specifications)20549 / 10493 (80 °C/300 V)
Cabling total (Standards and specifications)2 conductors longitudinally twisted
Colors driver (Standards and specifications)Brown, blue
Forward speed (Standards and specifications)3 m/s
Status indication (Environmental conditions)Not
Type of cable (Standards and specifications)PUR halogen-free black
Bending radius (Standards and specifications)48 mm
Oil resistance (Standards and specifications)according to DIN en 60811-2-1, 168 h at 100 °C
Journey forward (Standards and specifications)10 m
Other resistors (Standards and specifications)resistant to hydrolysis and microbes
Flame resistance (Standards and specifications)according to UL 758/1581 (horizontal)
Signal cable AWG (Standards and specifications)Eighteen
Special features (Standards and specifications)flexible
Insulation resistance (Environmental conditions)≥ 100 MΩ
Outer wrap, color (Standards and specifications)black-grey RAL 7021
Section of driver (Standards and specifications)2x 0.75 mm2 (conductor signals)
Absence of halogen (Standards and specifications)according to DIN VDE 0472 part 815
Test voltage Cable (Standards and specifications)≥ 3000 V AC Test (spark)
Conductive Material (Standards and specifications)Conductor Cu bare
Rated voltage Cable (Standards and specifications)≤ 300 V AC
Weight of the cable (Standards and specifications)33 kg/km
Class of flammability according to UL 94 (Material)V2
Class of flammability according to UL 94 (Overview)V2
Current sizing at 40 °C (Environmental conditions)8 To
Material contact surface valve connector (Overview)nickel-plated
Abbreviation of cable (Standards and specifications)Li9Y11Y
Insulation resistance (Standards and specifications)≥ 1 GΩ*km (at 20 °C)
Outer casing, material (Standards and specifications)PUR
Number of bending cycles (Standards and specifications)Four million
Cable type (abbreviation) (Standards and specifications)PUR
Material insert with contacts connector valve (Overview)PA 6.6
Outer diameter of cable D (Standards and specifications)4.8 mm ±0.15 mm
Wall thickness outer wrap (Standards and specifications)≥ 0.38 mm
Room temperature (service) (Standards and specifications)-40 °C ... 80 °C (cable, fixed)
Resistance of the conductor (Standards and specifications)≤ 26 Ω/km (at 20 °C)
Thickness of wall Insulation (Standards and specifications)≥ 0.21 mm
Material Insulation conductor (Standards and specifications)PP
Protective circuit/component protection (Environmental conditions)without connect
Construction of the driver signal cable (Standards and specifications)42x 0.15 mm
Diameter of the conductors, insulation included (Standards and specifications)1,69 mm ±0.05 mm (conductor signals)
Minimum bending radius, placed in a fixed manner (Standards and specifications)5 x D
Minimum bending radius, placed in a flexible way (Standards and specifications)10 x D

Product Description

Sensor/actuator cable, 2-pole, halogen-free PUR, grayish black RAL 7021, Straight male connector DEUTSCH DT04-2P Clip lock, to Straight connection female M12, coding: A, cable length: 0.3 m, Special c
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Cable for sensors/actuators, 2-pole, PUR halogen-free, black-gray RAL 7021, Plug straight male DEUTSCH DT04-2P Lock-clip, a connection socket straight M12, coded, cable length: 0.3 m, special Connection

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide