| Parameter | Value |
|---|---|
| 250 V DC | |
| Type | free cable end |
| Coding | A |
| Shielded | no |
| Cable type | PUR halogen-free black |
| Coding type | A |
| Acceleration | 10 m/s² |
| Cable length | 5 m |
| Cable weight | 25 kg/km |
| Halogen-free | in accordance with DIN VDE 0472 part 815 |
| Product type | Sensor/actuator cable |
| Short symbol | Li9Y11Y |
| UL AWM Style | 20549 / 10152 (80°C/300 V) |
| Seal material | NBR |
| Status display | No |
| AWG signal line | 20 |
| Traversing path | 10 m |
| Traversing rate | 3 m/s |
| Cable resistance | ≤ 39 Ω/km (at 20 °C) |
| Contact material | CuSn |
| Flame resistance | according to UL 758/1581 (horizontal) |
| Other resistance | hydrolysis and microbe resistant |
| Resistance to oil | According to DIN EN 60811-2-1, 168 h at 100°C |
| Conductor material | Bare Cu litz wires |
| Contact resistance | ≤ 5 mΩ |
| Nominal current IN | 4 A |
| Nominal voltage UN | 250 V AC |
| Protective circuit | unwired |
| Single wire, color | brown, blue |
| Special properties | flexible |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 4 |
| Test voltage, cable | ≥ 3000 V AC (Spark test) |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| External sheath, color | black-gray RAL 7021 |
| Nominal voltage, cable | ≤ 300 V AC |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 2x 0.5 mm² |
| External cable diameter | 4.25 mm ±0.15 mm |
| Thickness, outer sheath | ≥ 0.38 mm |
| Contact carrier material | TPU GF |
| Contact surface material | Ni/Au |
| Material wire insulation | PP |
| Number of bending cycles | 4000000 |
| Cable type (abbreviation) | PUR |
| Cable insulation resistance | ≥ 1 GΩ*km (at 20 °C) |
| Insertion/withdrawal cycles | ≥ 100 |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 1.46 mm ±0.05 mm |
| Ambient temperature (operation) | -25 °C ... 80 °C (Cable, flexible installation) |
| Conductor structure signal line | 28x 0.15 mm |
| Flammability rating according to UL 94 | HB |
| Minimum bending radius, fixed installation | 5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Minimum bending radius, drag chain applications | 10 x D |
| Contact | Color (signal designation) | Contact (optional) | 1 | BN |