Service time: Monday to Friday 9:00-18:00
SAC-17P-MS/ 3,0-35T SH SCO - SAC-17P-MS/ 3,0-35T SH SCO 1430213 PHOENIX CONTACT Sensor/actuator cable
In Stock Hot Product

SAC-17P-MS/ 3,0-35T SH SCO

SAC-17P-MS/ 3,0-35T SH SCO 1430213 PHOENIX CONTACT Sensor/actuator cable

$93.89USD
137 in stock
Key Specifications
:30 V DC
Type:Plug straight M12 SPEEDCON
Coding:A
Shielded:yes
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
30 V DC
TypePlug straight M12 SPEEDCON
CodingA
Shieldedyes
Cable typeBlack PUR/PVC twisted pair [35T]
ApplicationStandard
Coding typeA
Cable length3 m
Cable weight105 kg/km
Locking typeSPEEDCON
Product typeSensor/actuator cable
Test voltage1500 V AC
UL AWM Style20233 / 1061 (80°C/300 V)
Overall twist7 pairs and 1 three-way unit, intertwisted
Status displayno
AWG signal line26
Contact materialCuZn
Flame resistanceAccording to DIN EN 60332-1-2
Other resistancehydrolysis and microbe resistant (in accordance with EN 50396)
Resistance to oilin accordance with DIN EN 60811-2-1
Tightening torque0.4 Nm (M12 connector)
Conductor materialTin-plated Cu litz wires
Nominal current IN1.5 A
Nominal voltage UN30 V AC
Single wire, colorwhite-brown, green-yellow, gray-pink, blue-red, black-violet, gray/pink-red/blue, white/green-brown/green, white/yellow-yellow/brown-white/gray
Special propertiesFlexible cable conduit capable
Degree of pollution3
Dimensional drawing
Number of positions17
Degree of protectionIP65
No. of cable outlets1
Overvoltage categoryII
Standard designationM12 connector
Insulation resistance≥ 100 MΩ
Material of grip bodyTPU, hardly inflammable, self-extinguishing
External sheath, colorblack RAL 9005
Nominal voltage, cable42 V AC
Outer sheath, materialPUR
Status display presentNo
Conductor cross section17x 0.14 mm² (Signal line)
External cable diameter9.20 mm ±0.2 mm
Optical shield covering85 %
Contact carrier materialPA 6.6
Contact surface materialNi/Au
Material wire insulationPVC
Standards/specificationsIEC 61076-2-101
Max. conductor resistance142 Ω/km (at 20 °C)
Material for screw connectionZinc die-cast, nickel-plated
Wire diameter incl. insulation1 mm ±0.05 mm (Signal line)
Ambient temperature (operation)-30 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line18x 0.10 mm
Dynamic load capacity (bending)Max. bending cycles: 4000000, Bending radius: 92 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Flammability rating according to UL 94V0
Minimum bending radius, fixed installation5 x D
Smallest bending radius, fixed installation46 mm
Minimum bending radius, flexible installation10 x D
Smallest bending radius, movable installation92 mm

Product Description

Sensor/actuator cable, 17-pole, shielded, M12 straight connector, coding: A SPEEDCON, to free cable end, cable length: 3 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top