Service time: Monday to Friday 9:00-18:00
SAC-12P-3,0-35T/FS SH SCO - SAC-12P- 3,0-35T/FS SH SCO 1430132 PHOENIX CONTACT Sensor/actuator cable
In Stock Hot Product

SAC-12P-3,0-35T/FS SH SCO

SAC-12P- 3,0-35T/FS SH SCO 1430132 PHOENIX CONTACT Sensor/actuator cable

$49.32USD
252 in stock
Key Specifications
GTIN:4046356322409
(Cable):For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey:1430132
Catalog page:Page 220 (C-2-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356322409
(Cable)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Orderkey1430132
Catalog pagePage 220 (C-2-2017)
Packing unit1 pc
(Dimensions)IP67
Country of originDE (Germany)
China RoHS (Cable)Environmentally Friendly Use Period = 50
REACh SVHC (Cable)Lead 7439-92-1
Custom tariff number85444290
(Ambient conditions)30 V DC
Contact material (General)CuZn
Material, knurls (General)Zinc die-cast, nickel-plated
Sealing material (General)NBR
Coding (Ambient conditions)A - standard
Flame resistance (Material)DIN VDE 0472 part 804, test type B
Other resistance (Material)Hydrolysis and microbe resistant as per VDE 0282 section 10
Torque (Ambient conditions)0.4 Nm (M12 connector)
(Standards and Regulations)-5 °C ... 80 °C (cable, flexible installation)
Resistance to oil (Material)DIN VDE 0472 Part 803, test type B
Material of grip body (General)TPU, hardly inflammable, self-extinguishing
Standard designation (Material)M12 connector
Standards/regulations (Material)IEC 61076-2-101
Degree of protection (Dimensions)IP65
Contact carrier material (General)PA 6.6
Contact surface material (General)Ni/Au
Rated voltage (Ambient conditions)30 V AC
Status display (Ambient conditions)No
Weight per Piece (excluding packing)294.100 g
Length of cable (Key Commercial Data)3 m
Shielding (Standards and Regulations)Tinned copper braided shield
Cable type (Standards and Regulations)Black PUR/PVC twisted pair
Wire colors (Standards and Regulations)White-brown, green-yellow, gray-pink, blue-red, black-violet, gray/pink-red/blue
Acceleration (Standards and Regulations)10 m/s²
Cable weight (Standards and Regulations)87 kg/km
Degree of pollution (Ambient conditions)3
Halogen-free (Standards and Regulations)According to EN 50267-2-1
Number of positions (Ambient conditions)12
UL AWM style (Standards and Regulations)20233 / 1061 (80°C/300 V)
Overall twist (Standards and Regulations)Six pairs around the filler to the core
Overvoltage category (Ambient conditions)II
Twisted pairs (Standards and Regulations)2 cores to the pair
Bending radius (Standards and Regulations)85 mm
Insulation resistance (Ambient conditions)≥ 100 MΩ
Standards/regulations (Ambient conditions)M12 connector IEC 61076-2-101
AWG signal line (Standards and Regulations)26
Rated current at 40°C (Ambient conditions)1.5 A
Traversing path (Standards and Regulations)10 m
Traversing rate (Standards and Regulations)3 m/s
Ambient temperature (operation) (Dimensions)-25 °C ... 85 °C (Plug / socket)
Flame resistance (Standards and Regulations)According to DIN EN 60332-1-2
Other resistance (Standards and Regulations)hydrolysis and microbe resistant according to EN 50396
Resistance to oil (Standards and Regulations)in accordance with DIN EN 60811-2-1
Cable abbreviation (Standards and Regulations)LSPYwC11Y
Conductor material (Standards and Regulations)Tin-plated Cu litz wires
Special properties (Standards and Regulations)Flexible cable conduit capable
Test voltage, cable (Standards and Regulations)1500 V AC
Conductor resistance (Standards and Regulations)≤ 142 Ω/km (at 20 °C)
Flammability rating according to UL 94 (General)V0
Flammability rating according to UL 94 (Material)V0
Insulation resistance (Standards and Regulations)≥ 10 MΩ*km (at 20 °C)
Protective circuit/component (Ambient conditions)unwired
External sheath, color (Standards and Regulations)black RAL 9005
Material, inner sheath (Standards and Regulations)PVC
Nominal voltage, cable (Standards and Regulations)42 V AC
Outer sheath, material (Standards and Regulations)PUR
Conductor cross section (Standards and Regulations)12x 0.14 mm² (Signal line)
Optical shield covering (Standards and Regulations)85 %
Number of bending cycles (Standards and Regulations)2000000
Cable type (abbreviation) (Standards and Regulations)35T
External cable diameter D (Standards and Regulations)8.5 mm ±0.2 mm
Material conductor insulation (Standards and Regulations)PVC
Ambient temperature (operation) (Standards and Regulations)-30 °C ... 80 °C (cable, fixed installation)
Conductor structure signal line (Standards and Regulations)18x 0.10 mm
Core diameter including insulation (Standards and Regulations)1 mm ±0.05 mm (Signal line)
Stripping length of the free conductor end (Key Commercial Data)35 mm
Minimum bending radius, fixed installation (Standards and Regulations)5 x D
Minimum bending radius, flexible installation (Standards and Regulations)10 x D

Product Description

Sensor/actuator cable, 12-pole, shielded, free cable end, to Straight female M12, coding: A SPEEDCON, cable length: 3 m
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top