| Parameter | Value |
|---|---|
| 30 V DC | |
| Type | free cable end |
| Coding | A |
| Shielded | no |
| Cable type | PUR halogen-free black [PUR] |
| Application | Standard |
| Coding type | A |
| Cable length | 1.5 m |
| Cable weight | 17 kg/km |
| Halogen-free | in accordance with DIN EN 50267-2-1 |
| Locking type | SPEEDCON |
| Product type | Sensor/actuator cable |
| Test voltage | ≥ 1500 V |
| Overall twist | 12 wires twisted in layers |
| Seal material | NBR |
| Status display | no |
| AWG signal line | 26 |
| Article revision | 08 |
| Contact material | CuZn |
| Flame resistance | in acc. to UL VW1 |
| Other resistance | EN 50525-2-21:2012-01 |
| Resistance to oil | EN 60811-2-1 |
| Tightening torque | 0.4 Nm (M12 connector) |
| Conductor material | Tin-plated Cu litz wires |
| Nominal current IN | 1.5 A |
| Nominal voltage UN | 30 V AC |
| Single wire, color | white, brown, green, yellow, gray, pink, blue, red, black, violet, gray/pink, red/blue |
| Special properties | Low adhesion surface |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 12 |
| Degree of protection | IP65 |
| No. of cable outlets | 1 |
| Overvoltage category | II |
| Standard designation | M12 connector |
| Insulation resistance | ≥ 100 MΩ |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| External sheath, color | black RAL 9005 |
| Nominal voltage, cable | ≤ 300 V |
| Outer sheath, material | PUR |
| Status display present | No |
| Conductor cross section | 12x 0.14 mm² (Signal line) |
| External cable diameter | 7.20 mm |
| Contact carrier material | PA 6.6 |
| Contact surface material | Ni/Au |
| Material wire insulation | PP |
| Standards/specifications | IEC 61076-2-101 |
| Max. conductor resistance | 142 Ω/km |
| Material for screw connection | Zinc die-cast, nickel-plated |
| Wire diameter incl. insulation | 1 mm ±0.05 mm (Signal line) |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| Conductor structure signal line | 18x 0.10 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 4000000, Bending radius: 54 mm, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s² |
| Flammability rating according to UL 94 | V0 |
| Minimum bending radius, fixed installation | 5 x D |
| Smallest bending radius, fixed installation | 36 mm |
| Minimum bending radius, flexible installation | 10 x D |
| Smallest bending radius, movable installation | 72 mm |
Technical specifications and performance data