Service time: Monday to Friday 9:00-18:00
RSCWE 6-3/4SL - RSCWE 6-3/4SL 1029994 PHOENIX CONTACT Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Rin..
In Stock Hot Product

RSCWE 6-3/4SL

RSCWE 6-3/4SL 1029994 PHOENIX CONTACT Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Rin..

$0.00USD
3413 in stock
Key Specifications
GTIN:4055626532622
Orderkey:1029994
(Drawings):
Catalog page:Page 644 (C-1-2019)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626532622
Orderkey1029994
(Drawings)
Catalog pagePage 644 (C-1-2019)
Packing unit1
Pitch (General)8.2 mm
Width (General)55.6 mm
Color (Drawings)gray
Height (General)80.9 mm
Length (General)81.9 mm
UNSPSC 11 (ETIM)39121410
ETIM 4.0 (eCl@ss)EC000897
ETIM 5.0 (eCl@ss)EC000902
ETIM 6.0 (eCl@ss)EC000902
ETIM 7.0 (eCl@ss)EC000902
UNSPSC 13.2 (ETIM)39121410
UNSPSC 18.0 (ETIM)39121410
UNSPSC 19.0 (ETIM)39121410
UNSPSC 20.0 (ETIM)39121410
UNSPSC 21.0 (ETIM)39121410
UNSPSC 6.01 (ETIM)30211811
Setpoint (Drawings)5 N
UNSPSC 12.01 (ETIM)39121410
ASD level (Drawings)6.12 (m/s2)2/Hz
Custom tariff number85366990
UNSPSC 7.0901 (ETIM)39121410
Potentials (Drawings)4
Shock form (Drawings)Half-sine
Current Ith (Drawings)24 A
Acceleration (Drawings)30g
Connection (Dimensions)1 level
Test spectrum (Drawings)Service life test category 2, bogie-mounted
Plate thickness (General)1 mm ... 4 mm
Screw thread (Dimensions)No 8 UNC
Shock duration (Drawings)18 ms
Test frequency (Drawings)f1= 5 Hz to f2= 250 Hz
Bolt diameter (Dimensions)4.1 mm
Circuit diagram (Drawings)
Open side panel (Drawings)No
Test directions (Drawings)X-, Y- and Z-axis (pos. and neg.)
Number of levels (Drawings)1
Shock test result (Drawings)Test passed
eCl@ss 4.0 (Classifications)27141118
eCl@ss 4.1 (Classifications)27141118
eCl@ss 5.0 (Classifications)27141118
eCl@ss 5.1 (Classifications)27141100
eCl@ss 6.0 (Classifications)27141100
eCl@ss 7.0 (Classifications)27141126
eCl@ss 8.0 (Classifications)27141126
eCl@ss 9.0 (Classifications)27141126
Nominal voltage UN (Drawings)400 V AC/DC
Stripping length (Dimensions)12 mm
Test surge voltage (Drawings)5 kV
Connection method (Dimensions)Ring cable lug
Insulating material (Drawings)PA
Number of positions (Drawings)4
Rated surge voltage (Drawings)4 kV
Maximum load current (Drawings)30 A (with 10 mm² conductor cross section)
Mounting type (Connection data)Insertion in base strip
Overvoltage category (Drawings)III
Hole diameter, min. (Dimensions)4.3 mm
Nominal cross section (Drawings)6 mm²
Number of connections (Drawings)8
Plate thickness (Connection data)1 mm ... 4 mm
Result of thermal test (Drawings)Test passed
Test duration per axis (Drawings)5 h
Cable lug width, max. (Dimensions)8 mm
Tightening torque max (Dimensions)1.8 Nm
Tightening torque, min (Dimensions)1.5 Nm
Insulating material group (Drawings)I
Back of the hand protection (Drawings)guaranteed
Internal cylindrical gage (Dimensions)A5
Surge voltage test setpoint (Drawings)4.8 kV
Result of surge voltage test (Drawings)Test passed
NF F16-101, NF F10-102 Class F (Drawings)2
NF F16-101, NF F10-102 Class I (Drawings)2
Number of shocks per direction (Drawings)3
Result of tight fit on support (Drawings)Test passed
Test specification, shock test (Drawings)DIN EN 50155 (VDE 0115-200):2008-03
Note regarding shock protection (Drawings)
Connection in acc. with standard (Mounting)IEC 60947-7-1
Oxygen index (DIN EN ISO 4589-2) (Drawings)>32 %
Connection in acc. with standard (Dimensions)IEC 60947-7-1
Shock protection test specification (Drawings)DIN EN 50274 (VDE 0660-514):2002-11
Flame test method (DIN EN 60695-11-10) (Drawings)V0
Flammability rating according to UL 94 (Drawings)V0
Flammability rating according to UL 94 (Mounting)V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Drawings)passed
Conductor cross section flexible max. (Dimensions)10 mm²
Conductor cross section flexible min. (Dimensions)0.5 mm²
Oscillation, broadband noise test result (Drawings)Test passed
Power frequency withstand voltage setpoint (Drawings)1.89 kV
Surface flammability NFPA 130 (ASTM E 162) (Drawings)passed
Cable lug connection according to standard (Dimensions)DIN 46237:1970-07
Max. AWG conductor cross section, flexible (Dimensions)8
Min. AWG conductor cross section, flexible (Dimensions)24
Max. cross section for cable lug connection (Dimensions)10 mm²
Min. cross section for cable lug connection (Dimensions)0.5 mm²
Static insulating material application in cold (Drawings)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Drawings)Test passed
Maximum power dissipation for nominal condition (Drawings)1.31 W
Calorimetric heat release NFPA 130 (ASTM E 1354) (Drawings)27,5 MJ/kg
Result of power-frequency withstand voltage test (Drawings)Test passed
Test specification, oscillation, broadband noise (Drawings)DIN EN 50155 (VDE 0115-200):2008-03
2 conductors with same cross section, solid max. (Dimensions)6 mm²
2 conductors with same cross section, solid min. (Dimensions)0.5 mm²
2 conductors with same cross section, stranded max. (Dimensions)6 mm²
2 conductors with same cross section, stranded min. (Dimensions)0.5 mm²
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Drawings)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Drawings)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Drawings)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Drawings)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Drawings)passed
Relative insulation material temperature index (Elec., UL 746 B) (Drawings)130 °C
Proof of thermal characteristics (needle flame) effective duration (Drawings)30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Drawings)125 °C

Product Description

Test pin strip, rated voltage: 400 V, rated current: 24 A, number of connections: 8, number of poles: 4, connection type: Ring wire terminal, 1st floor, Sizing cross-section: 6 mm², mounting class: Wa
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Circuit diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top