| Parameter | Value |
|---|---|
| GTIN | 4055626532738 |
| Orderkey | 1029997 |
| (Drawings) | |
| Catalog page | Page 644 (C-1-2019) |
| Packing unit | 1 |
| Pitch (General) | 8.2 mm |
| Width (General) | 55.6 mm |
| Color (Drawings) | green |
| Height (General) | 80.9 mm |
| Length (General) | 81.9 mm |
| UNSPSC 11 (ETIM) | 39121410 |
| ETIM 4.0 (eCl@ss) | EC000897 |
| ETIM 5.0 (eCl@ss) | EC000902 |
| ETIM 6.0 (eCl@ss) | EC000902 |
| ETIM 7.0 (eCl@ss) | EC000902 |
| UNSPSC 13.2 (ETIM) | 39121410 |
| UNSPSC 18.0 (ETIM) | 39121410 |
| UNSPSC 19.0 (ETIM) | 39121410 |
| UNSPSC 20.0 (ETIM) | 39121410 |
| UNSPSC 21.0 (ETIM) | 39121410 |
| UNSPSC 6.01 (ETIM) | 30211811 |
| UNSPSC 12.01 (ETIM) | 39121410 |
| Custom tariff number | 85366990 |
| UNSPSC 7.0901 (ETIM) | 39121410 |
| Potentials (Drawings) | 4 |
| Current Ith (Drawings) | 24 A |
| Connection (Dimensions) | 1 level |
| Plate thickness (General) | 1 mm ... 4 mm |
| Screw thread (Dimensions) | No 8 UNC |
| Bolt diameter (Dimensions) | 4.1 mm |
| Circuit diagram (Drawings) | |
| Open side panel (Drawings) | No |
| Number of levels (Drawings) | 1 |
| eCl@ss 4.0 (Classifications) | 27141118 |
| eCl@ss 4.1 (Classifications) | 27141118 |
| eCl@ss 5.0 (Classifications) | 27141118 |
| eCl@ss 5.1 (Classifications) | 27141100 |
| eCl@ss 6.0 (Classifications) | 27141100 |
| eCl@ss 7.0 (Classifications) | 27141126 |
| eCl@ss 8.0 (Classifications) | 27141126 |
| eCl@ss 9.0 (Classifications) | 27141126 |
| Nominal voltage UN (Drawings) | 400 V AC/DC |
| Stripping length (Dimensions) | 12 mm |
| Test surge voltage (Drawings) | 5 kV |
| Connection method (Dimensions) | Ring cable lug |
| Insulating material (Drawings) | PA |
| Number of positions (Drawings) | 4 |
| Rated surge voltage (Drawings) | 4 kV |
| Maximum load current (Drawings) | 30 A (with 10 mm² conductor cross section) |
| Mounting type (Connection data) | Insertion in base strip |
| Overvoltage category (Drawings) | III |
| Hole diameter, min. (Dimensions) | 4.3 mm |
| Nominal cross section (Drawings) | 6 mm² |
| Number of connections (Drawings) | 8 |
| Plate thickness (Connection data) | 1 mm ... 4 mm |
| Cable lug width, max. (Dimensions) | 8 mm |
| Tightening torque max (Dimensions) | 1.8 Nm |
| Tightening torque, min (Dimensions) | 1.5 Nm |
| Insulating material group (Drawings) | I |
| Internal cylindrical gage (Dimensions) | A5 |
| Connection in acc. with standard (Mounting) | IEC 60947-7-1 |
| Connection in acc. with standard (Dimensions) | IEC 60947-7-1 |
| Flammability rating according to UL 94 (Drawings) | V0 |
| Flammability rating according to UL 94 (Mounting) | V0 |
| Conductor cross section flexible max. (Dimensions) | 10 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.5 mm² |
| Cable lug connection according to standard (Dimensions) | DIN 46237:1970-07 |
| Max. AWG conductor cross section, flexible (Dimensions) | 8 |
| Min. AWG conductor cross section, flexible (Dimensions) | 24 |
| Max. cross section for cable lug connection (Dimensions) | 10 mm² |
| Min. cross section for cable lug connection (Dimensions) | 0.5 mm² |
| Maximum power dissipation for nominal condition (Drawings) | 1.31 W |
| 2 conductors with same cross section, solid max. (Dimensions) | 6 mm² |
| 2 conductors with same cross section, solid min. (Dimensions) | 0.5 mm² |
| 2 conductors with same cross section, stranded max. (Dimensions) | 6 mm² |
| 2 conductors with same cross section, stranded min. (Dimensions) | 0.5 mm² |
Technical specifications and performance data
Installation and operation guide