Key Specifications
:4 A (380 - 440 V)
Color:silver/black
Width:48 mm
Height:48 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
4 A (380 - 440 V)
Colorsilver/black
Width48 mm
Height48 mm
Length62.5 mm
Hole diameter7 mm
Additional textValid for networks with grounded neutral point, overvoltage category III, pollution degree 3
Switching angle90 °
Breaking capacity150 A (220 - 240 V)
Installation depth33.50 mm
Rated surge voltage6 kV
Maximum load current20 A
Number of connections4
Rotary switch function1 ‑ 2
Rated continuous current20 A
Rated insulation voltage690 V
Switching program numberS0530
Ambient temperature (operation)-35 °C ... 55 °C (Open, at 100% load, with peaks up to 60°C)
Conductor cross section AWG max.14
Conductor cross section AWG min.20
Conductor cross section solid max.2.5 mm²
Conductor cross section solid min.0.5 mm²
Rated short-time current resistance140 A
Conductor cross section flexible max.2.5 mm²
Conductor cross section flexible min.0.75 mm²
Max. AWG conductor cross section, flexible14
Min. AWG conductor cross section, flexible18
2 conductors with same cross section, solid max.2.5 mm²
2 conductors with same cross section, solid min.0.5 mm²
2 conductors with same cross section, stranded max.2.5 mm²
2 conductors with same cross section, stranded min.0.75 mm²
IP immunity to short-circuiting with maximum backup fuse25 A
Two conductors with the same cross section, AWG solid max.14
Two conductors with the same cross section, AWG solid min.20
Two conductors with the same cross section, AWG stranded, max.14
Two conductors with the same cross section, AWG stranded, min.18
Conductor cross section / stranded with ferrule with plastic sleeve min.1.5 mm²
Conductor cross section / stranded, with ferrule with plastic sleeve max.1.5 mm²
Conductor cross section / stranded with ferrule without plastic sleeve max.2.5 mm²
Conductor cross section / stranded with ferrule without plastic sleeve min.2.5 mm²
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, maximum1.5 mm²
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, minimum1.5 mm²
Rated operating current according to AC-21A (switching of ohmic loads including small overloads)20 A
Switching power according to AC-4 (squirrel-cage motors: starting, reversing, plugging, inching)0.55 kW (220 - 240 V; 3-phase, 3-pos.)
Switching power according to AC-23A (frequent switching of motors or other highly inductive loads)3.7 kW (220 - 240 V; 3-phase, 3-pos.)
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, maximum2.5 mm²
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, minimum2.5 mm²
Rated operating current according to AC-15 (switching of solenoid drives, contactors, valves, pulling electromagnets)5 A (220 - 240 V)
Rated operating current according to AC-22A (switching of mixed ohmic and inductive loads, including small overloads)20 A (220 - 500 V)
Switching power according to AC-3 (squirrel-cage motors: direct starting, switching off motors during operation, star-delta startup (CH16B))3 kW (220 - 240 V; 3-phase, 3-pos.)

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top