| Parameter | Value |
|---|---|
| GTIN | 4046356174114 |
| Orderkey | 2916600 |
| Catalog page | Page 87 (C-6-2017) |
| Depth (Note) | 190 mm |
| Packing unit | 1 pc |
| Width (Note) | 124 mm |
| Height (Note) | 185 mm |
| (Power supply) | 124 x 210 x 190 mm (W x H x D with fan) |
| Country of origin | DE (Germany) |
| Shock (Dimensions) | 25g, Criterion 1, according to IEC 60068-2-27 |
| Custom tariff number | 85371091 |
| Shock (General data) | 25g, Criterion 1, according to IEC 60068-2-27 |
| Format (Power supply) | 124 x 185 x 190 mm (W x H x D without fan) |
| Input name (PROFINET) | Digital inputs |
| Weight (Power supply) | 2010 g |
| Output name (PROFINET) | Digital outputs |
| Number (Fieldbus function) | 1 |
| Number of inputs (PROFINET) | 5 |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Connection method (PROFINET) | 14-pos. FLK pin strip |
| Number of outputs (PROFINET) | 3 |
| Supply voltage (Direct I/Os) | 24 V DC |
| Interface (Fieldbus function) | Parameterization/operation/diagnostics |
| Mass storage (Control system) | 16 Mbyte |
| Processor (Mechanical design) | Intel®Celeron®927 UE 1.5 GHz |
| Update rate (Data interfaces) | min. 1 ms |
| Safety function (Power supply) | No |
| Power dissipation (Direct I/Os) | max. 24 W |
| Program memory (Control system) | typ. 8 Mbyte |
| Realtime clock (Control system) | Integrated (battery backup) |
| Specification (Data interfaces) | Version 1.1 |
| Connection technology (PROFINET) | FLK cable connector (14-pos.) |
| Degree of protection (Dimensions) | IP20 |
| Device function (Data interfaces) | PROFINET controller, PROFINET device |
| Engineering tool (Control system) | PC WORX |
| Diagnostics display (Power supply) | yes |
| Supply voltage range (Direct I/Os) | 19.2 V DC ... 30 V DC (including ripple) |
| Vibration (operation) (Dimensions) | 1g, Criterion 1, according to IEC 60068-2-6 |
| Controller redundancy (Power supply) | No |
| Vibration (operation) (General data) | 1g, Criterion 1, according to IEC 60068-2-6 |
| Weight per Piece (excluding packing) | 2,150.000 g |
| Air pressure (operation) (Dimensions) | 80 kPa ... 108 kPa (up to 2000 m above sea level) |
| Connection method (Fieldbus function) | D-SUB 9 plug |
| Diagnostics tool (Ambient conditions) | DIAG+, version 2.00 or higher |
| Engineering tool (Ambient conditions) | PC WORX |
| Power supply connection (Direct I/Os) | Screw terminal blocks, plug-in |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Standards and Regulations) | 1,2-dimethoxyethane,ethylene glycol dimethyl ether (EGDME) 110-71-4 |
| Transmission speed (Fieldbus function) | 500 kBaud / 2 MBaud (can be switched) |
| Retentive mass storage (Control system) | 240 kByte (NVRAM) |
| Number of control tasks (Control system) | 16 |
| Typical current consumption (Direct I/Os) | 1 A |
| Ambient temperature (operation) (Dimensions) | 0 °C ... 55 °C (from 45°C only with fan module) |
| Note on weight specifications (Power supply) | with fan module |
| Vibration (storage/transport) (General data) | 1g, Criterion 1, according to IEC 60068-2-6 |
| Air pressure (storage/transport) (Dimensions) | 66 kPa ... 108 kPa (up to 3000 m above sea level) |
| Permissible humidity (operation) (Dimensions) | 5 % ... 90 % (non-condensing) |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Amount of process data (IEC 61131 runtime system) | max. 8192 Bit (INTERBUS-Master) |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 70 °C |
| Programming languages supported (Ambient conditions) | Programming in acc. with IEC 61131-3 |
| Permissible humidity (storage/transport) (Dimensions) | 5 % ... 90 % (non-condensing) |
| Number of supported devices (IEC 61131 runtime system) | max. 512 (of which 254 are remote bus devices/bus segments) |
| Number of devices with parameter channel (IEC 61131 runtime system) | max. 126 |
Technical specifications and performance data