| Parameter | Value |
|---|---|
| GTIN | 4017918941772 |
| Orderkey | 2834274 |
| (Coil side) | 5 A (N/C contact) |
| Catalog page | Page 390 (C-7-2015) |
| Packing unit | 10 pc |
| Country of origin | CN (China) |
| Custom tariff number | 85364190 |
| Minimum order quantity | 10 pc |
| Contact type (Coil side) | 3 PDTs |
| Depth (Key Commercial Data) | 52.5 mm |
| Width (Key Commercial Data) | 34.5 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Contact material (Coil side) | AgSnIn |
| Height (Key Commercial Data) | 34.5 mm |
| Degree of pollution (General) | 3 |
| Operating mode (Contact side) | 100% operating factor |
| Overvoltage category (General) | II |
| Net weight (SAP) (Contact side) | 99.37 g |
| Standards/regulations (General) | IEC 60664 |
| Mounting position (Contact side) | any |
| Maximum inrush current (Coil side) | on request |
| Min. switching current (Coil side) | 10 mA |
| Type of switch contact (Coil side) | Single contact |
| Degree of protection (Contact side) | RT I |
| Assembly instructions (Contact side) | On relay base PR3 |
| Coil resistance (Ambient conditions) | 430 Ω ±15 % (at 20 °C) |
| Weight per Piece (excluding packing) | 99.370 g |
| Maximum switching voltage (Coil side) | 250 V AC/DC |
| Minimum switching voltage (Coil side) | 1 V |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Mechanical service life (Contact side) | 10x 106cycles |
| Limiting continuous current (Coil side) | 10 A (N/O contact) |
| Service life, electrical (Contact side) | see diagram |
| Typical release time (Ambient conditions) | 6 ms |
| Connection in acc. with standard (General) | CUL |
| Typical response time (Ambient conditions) | 12 ms |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 60 °C |
| Nominal input voltage UN (Ambient conditions) | 24 V DC |
| Typical input current at UN (Ambient conditions) | 56 mA |
| Interrupting rating (ohmic load) max. (Coil side) | 2500 VA (for 250 V AC) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 60 °C |
| Test voltage relay contact/relay contact (Contact side) | 2.5 kV AC (50 Hz, 1 min.) |
| Test voltage relay winding/relay contact (Contact side) | 2.5 kV AC (50 Hz, 1 min.) |
| Input voltage range in reference to UN (Ambient conditions) | 0.8 ... 1.1 |
| Power dissipation for nominal condition (Ambient conditions) | 1.34 W |
Technical specifications and performance data