| Parameter | Value |
|---|---|
| 11 mA (At 60 Hz) | |
| Depth | 52.5 mm |
| Width | 34.5 mm |
| Height | 34.5 mm |
| Altitude | ≤ 2000 m |
| Product type | Single relay |
| Assembly note | On relay base PR3 |
| Operating mode | 100% operating factor |
| Coil resistance | 6170 Ω ±15 % (at 20 °C) |
| Mains frequency | 50/60 Hz |
| Contact material | AgSnIn |
| Pollution degree | 3 |
| Connection method | Plug-in connection |
| Mounting position | any |
| Drive and function | monostable |
| Input voltage range | 184 V AC ... 253 V AC |
| Degree of protection | RT I |
| Overvoltage category | II |
| Standards/regulations | IEC 60664 |
| Typical response time | 5 ms ... 20 ms (AC, depending on phase relation) |
| Contact switching type | 2 changeover contacts |
| Maximum inrush current | on request |
| Min. switching current | 10 mA |
| Type of switch contact | Single contact |
| Mechanical service life | 10x 106cycles |
| Service life electrical | see diagram |
| Nominal input voltage UN | 230 V AC |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 1 V |
| Typical release time range | 5 ms ... 20 ms (AC, depending on phase relation) |
| Limiting continuous current | 10 A (N/O contact) |
| Typical input current at UN | 10 mA (at 50 Hz) |
| Date of last data management | 22.05.2024 |
| Test voltage (Contact/contact) | 2.5 kV AC (50 Hz, 1 min., contact/contact) |
| Test voltage (Winding/contact) | 2.5 kV AC (50 Hz, 1 min., winding/contact) |
| Ambient temperature (operation) | -40 °C ... 60 °C |
| Interrupting rating (ohmic load) max. | 2500 VA (for 250 V AC) |
| Input voltage range in reference to UN | 0.8 ... 1.1 |
| Ambient temperature (storage/transport) | -40 °C ... 60 °C |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Maximum power dissipation for nominal condition | 2.3 W |
Technical specifications and performance data