| Parameter | Value |
|---|---|
| GTIN | 4055626279411 |
| Orderkey | 2908182 |
| (General) | IEC 60664 |
| (Coil side) | 66 W (at 220 V DC) |
| Catalog page | Page 308 (C-5-2017) |
| Packing unit | 10 pc |
| Country of origin | CN (China) |
| Custom tariff number | 85364190 |
| Minimum order quantity | 10 pc |
| Contact type (Coil side) | 2 PDT |
| Depth (Key Commercial Data) | 25.5 mm |
| Width (Key Commercial Data) | 13 mm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Contact material (Coil side) | AgNi |
| Height (Key Commercial Data) | 29 mm |
| Degree of pollution (General) | 2 |
| Operating mode (Contact side) | 100% operating factor |
| Overvoltage category (General) | III |
| Net weight (SAP) (Contact side) | 17.64 g |
| Standards/regulations (General) | IEC 61810 |
| Mounting position (Contact side) | any |
| Maximum inrush current (Coil side) | 16 A (20 ms) |
| Min. switching current (Coil side) | 10 mA (at 12 V) |
| Rated insulation voltage (General) | 250 V AC |
| Type of switch contact (Coil side) | Single contact |
| Degree of protection (Contact side) | RT II |
| Status display (Ambient conditions) | Yellow LED |
| Test voltage PDT/PDT (Contact side) | 2.5 V AC (50 Hz, 1 min.) |
| Mains frequency (Ambient conditions) | 50/60 Hz |
| Weight per Piece (excluding packing) | 17.640 g |
| Maximum switching voltage (Coil side) | 250 V AC/DC |
| Minimum switching voltage (Coil side) | 12 V (at 10 mA) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Mechanical service life (Contact side) | 5x 106cycles |
| Limiting continuous current (Coil side) | 8 A |
| Service life, electrical (Contact side) | see diagram |
| Typical response time (Ambient conditions) | 3 ms ... 12 ms (depending on phase relation) |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 70 °C |
| Nominal input voltage UN (Ambient conditions) | 200 V AC |
| Typical release time range (Ambient conditions) | 2 ms ... 8 ms (depending on phase relation) |
| Typical input current at UN (Ambient conditions) | 4 mA |
| Interrupting rating (ohmic load) max. (Coil side) | 192 W (at 24 V DC) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Test voltage relay winding/relay contact (Contact side) | 5 kV AC (50 Hz, 1 min.) |
| Input voltage range in reference to UN (Ambient conditions) | 0.8 ... 1.35 (see diagram) |
| Power dissipation for nominal condition (Ambient conditions) | 0.8 W |
Technical specifications and performance data