| Parameter | Value |
|---|---|
| GTIN | 4017918187569 |
| Orderkey | 2961341 |
| (General) | EN 61810-1 |
| (Coil side) | 1 HP, 250 V AC (N/O contact) |
| Catalog page | Page 393 (C-5-2017) |
| Packing unit | 10 pc |
| Country of origin | AT (Austria) |
| Custom tariff number | 85366990 |
| Insulation (General) | Safe isolation, reinforced insulation |
| Minimum order quantity | 10 pc |
| Contact type (Coil side) | 1 N/O contact |
| Depth (Key Commercial Data) | 15.7 mm |
| Width (Key Commercial Data) | 12.7 mm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Contact material (Coil side) | AgSnO |
| Height (Key Commercial Data) | 29 mm |
| Degree of pollution (General) | 3 |
| Maximum altitude (Dimensions) | ≤ 2000 m |
| Operating mode (Contact side) | 100% operating factor |
| Rated surge voltage (General) | 6 kV |
| Overvoltage category (General) | III |
| Switching capacity (Coil side) | 2 A (at 24 V, DC13) |
| Net weight (SAP) (Contact side) | 12.815 g |
| Standards/regulations (General) | EN 50178 |
| Mounting position (Contact side) | any |
| Maximum inrush current (Coil side) | 80 A (20 ms) |
| Min. switching current (Coil side) | 100 mA (at 12 V DC) |
| Rated insulation voltage (General) | 250 V AC |
| Type of switch contact (Coil side) | Single contact |
| Degree of protection (Contact side) | RT II (flux-proof) |
| Switching capacity min. (Coil side) | 1200 mW |
| Assembly instructions (Contact side) | Can be aligned without spacing (> 70 °C ≥ 2.5 mm) |
| Coil resistance (Ambient conditions) | 1440 Ω ±10 % (20 °C) |
| Weight per Piece (excluding packing) | 12.820 g |
| Maximum switching voltage (Coil side) | 250 V AC/DC |
| Minimum switching voltage (Coil side) | 12 V (100 mA) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Mechanical service life (Contact side) | 3x 107cycles |
| Limiting continuous current (Coil side) | 16 A |
| Typical release time (Ambient conditions) | 3 ms |
| Connection in acc. with standard (General) | CUL |
| Motor load according to UL 508 (Coil side) | 1/2 HP, 120 V AC (N/O contact) |
| Typical response time (Ambient conditions) | 8 ms |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 85 °C |
| Nominal input voltage UN (Ambient conditions) | 24 V DC |
| Typical input current at UN (Ambient conditions) | 17 mA |
| Interrupting rating (ohmic load) max. (Coil side) | 384 W (at 24 V DC) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Test voltage relay winding/relay contact (Contact side) | 5 kV AC (50 Hz, 1 min.) |
| Input voltage range in reference to UN (Ambient conditions) | see diagram |
| Power dissipation for nominal condition (Ambient conditions) | 0.41 W |
Technical specifications and performance data