| Parameter | Value |
|---|---|
| GTIN | 4055626379685 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2909738 |
| (General) | IEC 61810 |
| (Coil side) | 1 A (at 230 V, AC15) |
| Packing unit | 10 pc |
| Country of origin | PL (Poland) |
| Custom tariff number | 85364190 |
| Insulation (General) | Basic insulation |
| Contact type (Coil side) | 4 PDTs |
| Depth (Key Commercial Data) | 35.6 mm |
| Width (Key Commercial Data) | 21.2 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Contact material (Coil side) | AgNi |
| Height (Key Commercial Data) | 27.5 mm |
| Degree of pollution (General) | 2 |
| Operating mode (Contact side) | 100% operating factor |
| Rated surge voltage (General) | 2.5 kV |
| Overvoltage category (General) | II |
| Switching capacity (Coil side) | 2 A (at 24 V, DC13) |
| Standards/regulations (General) | IEC 60664 |
| Mounting position (Contact side) | any |
| Maximum inrush current (Coil side) | 16 A (20 ms, N/O contact) |
| Min. switching current (Coil side) | 5 mA (at 24 V) |
| Rated insulation voltage (General) | 250 V AC |
| Type of switch contact (Coil side) | Single contact |
| Degree of protection (Contact side) | RT III |
| Switching capacity min. (Coil side) | 0.12 W |
| Test voltage PDT/PDT (Contact side) | 2.5 kVrms(50 Hz, 1 min.) |
| Weight per Piece (excluding packing) | 35.430 g |
| Maximum switching voltage (Coil side) | 250 V AC/DC |
| Minimum switching voltage (Coil side) | 5 V (At 24 mA) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Mechanical service life (Contact side) | 1x 107cycles, approximately |
| Limiting continuous current (Coil side) | 6 A |
| Typical release time (Ambient conditions) | 3 ms |
| Motor load according to UL 508 (Coil side) | 1/3 HP, 240 V AC |
| Typical response time (Ambient conditions) | 13 ms |
| Ambient temperature (operation) (Dimensions) | -40 °C ... 70 °C |
| Nominal input voltage UN (Ambient conditions) | 24 V DC |
| Typical input current at UN (Ambient conditions) | 38 mA |
| Interrupting rating (ohmic load) max. (Coil side) | 144 W (at 24 V DC) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Test voltage relay winding/relay contact (Contact side) | 2.5 kVrms(50 Hz, 1 min.) |
| Switching capacity according to IEC 60947-5-1 (Coil side) | 2 A (at 24 V, DC13) |
| Input voltage range in reference to UN (Ambient conditions) | see diagram |
| Power dissipation for nominal condition (Ambient conditions) | 0.91 W |
Technical specifications and performance data