Key Specifications
:NS 35/15
Color:gray (RAL 7042)
Width:15 mm
Height:80.8 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
NS 35/15
Colorgray (RAL 7042)
Width15 mm
Height80.8 mm
ResultTest passed
SpectrumService life test category 1, class B, body mounted
ASD level0.964 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 150 Hz
Potentials1
Bolt length17 mm
Pulse shapeHalf-sine
Acceleration5.72g
Product typeBolt connection terminal block
Screw threadM6
Bolt diameter6 mm
Cross section6 mm² ... 35 mm²
Hole diameter6.5 mm
Mounting typeNS 35/7,5
SpecificationDIN EN 50155 (VDE 0115-200):2018-05
Number of rows1
Shock duration18 ms
Nominal current125 A
Nominal voltage1000 V
Open side panelNo
Test directionsX-, Y- and Z-axis
Article revision00
Stripping lengthThe stripping length depends on the specification provided by the cable lug manufacturer.
Time of exposure30 s
Cross section AWG12 ... 2 (converted acc. to IEC)
Tightening torque3.2 ... 3.7 Nm
Depth on NS 35/1557.3 mm
Degree of pollution3
Depth on NS 35/7,549.8 mm
Insulating materialPA
Number of positions1
Rated surge voltage8 kV
Maximum load current125 A (with 35 mm² conductor cross section)
Overvoltage categoryIII
Nominal cross section35 mm²
Number of connections2
Test voltage setpoint2.2 kV
Test duration per axis5 h
Cross section range AWG(converted acc. to IEC)
DIN rail/fixing supportNS 35/7,5
Insulating material groupI
Conductor cross section rigid2.5 mm² ... 35 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level2
Conductor cross section flexible2.5 mm² ... 35 mm²
Connection in acc. with standardIEC 60947-7-1
Permissible humidity (operation)20 % ... 90 %
Requirement temperature-rise testIncrease in temperature ≤ 45 K
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG]12 ... 2 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
Identification color of ring cable lugs : blue2.5 mm²
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition4.06 W
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Identification color of ring cable lugs : yellow6 mm²
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

Product Description

Stud connection terminal, nominal voltage: 1000 V, nominal current: 125 A, number of connections: 2, number of poles: 1, connection type: Stud connection, 1st floor, Sizing cross-section: 35 mm², cros
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top