Key Specifications
:24 V DC
LED:yes
Time:186000 h
Depth:125 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
24 V DC
LEDyes
Time186000 h
Depth125 mm
I/O/Sasymmetrical
Input2 kV (Test Level 4 - asymmetrical)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Width32 mm
Height130 mm
Output2 kV (Test Level 4 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
Current40 A
Defaultopen
Voltage10 V (Test Level 3)
CommentsCriterion B
Derating60 °C ... 70 °C (2.5 %/K)
Frequency16.67 Hz
Efficiencytyp. 99.1 % (12 V DC)
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Temperature40 °C
UIn< 8 V DCLED off, input voltage not present or short circuit at redundancy module output
UIn> 8 V DCLED lights up green, input voltage present
Hood versionGalvanized sheet steel, free from chrome (VI)
Product typeRedundancy module
Screw threadM4
UL approvalsUL/C-UL listed UL 508
Assembly notealignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Mounting typeDIN rail mounting
Climatic class3K3 (in acc. with EN 60721)
Noise emissionAdditional basic standard EN 61000-6-5 (immunity in power station)
Product familyQUINT S-ORING
Additional textUIN
Frequency range80 MHz ... 1 GHz
Type of housingAluminum (AlMg3)
Article revision03
Discharge in air15 kV (Test Level 4)
Housing materialMetal
Maximum altitude≤ 5000 m (> 2000 m, observe derating)
Protection classIII
Stripping length10 mm
Connection methodScrew connection
Contact discharge8 kV (Test Level 4)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Input current ISFB215 A (15 ms)
Output descriptionGroup contact
Types of signalingRelay contact, floating, current limited
Current consumption40 A
Degree of pollution2
Dimensional drawing
Input voltage range8 V DC ... 30 V DC
Test field strength20 V/m (Test Level 3)
Connection in seriesno
Degree of protectionIP20
Input current IStatic45 A (40 °C)
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Shipbuilding approvalDNV GL
Standards/regulationsEN 61000-4-2
Tightening torque max1.5 Nm
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Input current IDynamic60 A (5 s)
Maximum inrush current≤ 100 mA (short-circuit-proof)
Nominal output voltageUIn- 0.1 V
Tightening torque, min1.2 Nm
DNV GL noise radiationClass B
Redundancy modul faultyLED lights up red, redundancy module needs to be factory tested
Conducted noise emissionEN 55016
Maximum switching voltagemax. 30 V AC/DC
Standard - Safe isolationDIN VDE 0100-410
Dynamic Boost (IDyn.Boost)60 A (5 s)
MTBF (IEC 61709, SN 29500)> 25297000 h (25 °C)
Nominal input current (IN)40 A (-40 °C ... 60 °C)
Static Boost (IStat.Boost)45 A
Transient surge protectionVaristor
Voltage drop, input/output0.1 V
Nominal input voltage range12 V DC ... 24 V DC
Nominal output current (IN)40 A
Reverse polarity protection< yes60 V
Power loss nominal load max.6.5 W (IOUT= 40 A)
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Typical national grid voltage12 V DC
DNV GL conducted interferenceClass A
Selective Fuse Breaking (ISFB)215 A (15 ms)
Voltage type of supply voltageDC
Ambient temperature (operation)-40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Conductor cross section AWG max.6
Conductor cross section AWG min.20
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom40 mm / 20 mm
SIL in accordance with IEC 615080
Conductor cross section, rigid max.16 mm²
Conductor cross section, rigid min.0.5 mm²
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise immunityEN 61000-6-1
Conductor cross section flexible max.16 mm²
Conductor cross section flexible min.0.5 mm²
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Insulation voltage input, output / housing500 V DC
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Flammability rating according to UL 94 (housing / terminal blocks)V0
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.16 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.16 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.5 mm²
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

Product Description

Active single QUINT redundancy module for rail mounting, 12 to 24 VDC input, 12 to 24 VDC / 1 x 40 A output, including UTA 107/30 rail universal adapter mounted
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top