Service time: Monday to Friday 9:00-18:00
QUINT4-S-ORING/12-24DC/1X40/VP - QUINT4-S-ORING/12-24DC/1X40/VP 1043418 PHOENIX CONTACT Active QUINT single redundancy module for DIN rail mo..
In Stock Hot Product

QUINT4-S-ORING/12-24DC/1X40/VP

QUINT4-S-ORING/12-24DC/1X40/VP 1043418 PHOENIX CONTACT Active QUINT single redundancy module for DIN rail mo..

$0.00USD
4350 in stock
Key Specifications
GTIN:4055626607474
Orderkey:1043418
(Drawings):
(Standards):UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626607474
Orderkey1043418
(Drawings)
(Standards)UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Catalog pagePage 305 (C-4-2019)
Packing unit1
(Input data)6 W (IOUT= 40 A)
(Output data)> 3379000 h (60 °C)
Depth (Drawings)125 mm
Width (Drawings)32 mm
ETIM 5.0 (eCl@ss)EC000683
ETIM 6.0 (eCl@ss)EC000683
ETIM 7.0 (eCl@ss)EC000683
Height (Drawings)130 mm
Diagram (Drawings)
Custom tariff number85049090
Derating (Input data)60 °C ... 70 °C (2.5%/K)
REACh SVHC (EMC data)Lead 7439-92-1
Screw thread (General)M4
(Conformance/approvals)60 Hz
Block diagram (Drawings)
Efficiency (Output data)typ. 99 % (12 V DC)
Net weight (Output data)0.4 kg
UL approvals (Standards)UL/C-UL listed UL 508
Stripping length (General)10 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Screw connection
eCl@ss 8.0 (Classifications)27371010
eCl@ss 9.0 (Classifications)27371010
I/O/S (Conformance/approvals)asymmetrical
Input (Conformance/approvals)1 kV (Test Level 4 - symmetrical)
Output (Conformance/approvals)1 kV (Test Level 2 - symmetrical)
Protection class (Output data)III
Signal (Conformance/approvals)1 kV (Test Level 2 - asymmetrical)
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
Voltage (Conformance/approvals)10 V (Test Level 3)
Comments (Conformance/approvals)Criterion A
Degree of pollution (Dimensions)2
Installation height (Dimensions)≤ 5000 m (> 2000 m, observe derating)
Connection in series (Input data)No
Degree of protection (Dimensions)IP20
Frequency (Conformance/approvals)16.67 Hz
Output voltage range (Input data)8 V DC ... 27.5 V DC
Degree of protection (Output data)IP20
Assembly instructions (Output data)alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Criterion A (Conformance/approvals)Normal operating behavior within the specified limits.
Criterion B (Conformance/approvals)Temporary impairment to operational behavior that is corrected by the device itself.
Screw thread (Connection data, input)M4
Noise emission (Conformance/approvals)EN 55016
Additional text (Conformance/approvals)60 s
Dynamic Boost (IDyn.Boost) (Input data)60 A (5 s)
Frequency range (Conformance/approvals)0.15 MHz ... 80 MHz
Static Boost (IStat.Boost) (Input data)45 A
Current consumption (Ambient conditions)40 A
Discharge in air (Conformance/approvals)15 kV (Test Level 4)
Input voltage range (Ambient conditions)8 V DC ... 27.5 V DC (SELV)
MTBF (IEC 61709, SN 29500) (Output data)> 13486000 h (25 °C)
Nominal output current (IN) (Input data)40 A
Contact discharge (Conformance/approvals)8 kV (Test Level 4)
Power loss nominal load max. (Input data)6.5 W (IOUT= 40 A)
Stripping length (Connection data, input)10 mm
Conductor cross section AWG max. (General)6
Conductor cross section AWG min. (General)20
Connection method (Connection data, input)Screw connection
Depth with alternative assembly (Drawings)35 mm
Nominal input current (Ambient conditions)40 A (-40 °C ... 60 °C)
Stripping length (Connection data, output)8 mm
Width with alternative assembly (Drawings)122 mm
Connection method (Connection data, output)Push-in connection
Height with alternative assembly (Drawings)130 mm
Selective Fuse Breaking (ISFB) (Input data)215 A (15 ms)
Test field strength (Conformance/approvals)30 A/m
Ambient temperature (operation) (Dimensions)-40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)16 mm²
Conductor cross section solid min. (General)0.5 mm²
Low Voltage Directive (Conformance/approvals)Conformance with Low Voltage Directive 2014/35/EC
Conductor cross section flexible max. (General)16 mm²
Conductor cross section flexible min. (General)0.5 mm²
DNV GL noise radiation (Conformance/approvals)Class B
Electrostatic discharge (Conformance/approvals)EN 61000-4-2
Fast transients (burst) (Conformance/approvals)EN 61000-4-4
Conducted noise emission (Conformance/approvals)EN 55016
Electromagnetic HF field (Conformance/approvals)EN 61000-4-3
Nominal input voltage range (Ambient conditions)12 V DC ... 24 V DC
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Electromagnetic compatibility (Conformance/approvals)Conformance with EMC Directive 2014/30/EU
DNV GL conducted interference (Conformance/approvals)Class A
Conductor cross section AWG max. (Connection data, input)6
Conductor cross section AWG min. (Connection data, input)20
Standard - Safe isolation (Connection data for signaling)DIN VDE 0100-410
Conductor cross section AWG max. (Connection data, output)16
Conductor cross section AWG min. (Connection data, output)24
Conductor cross section solid max. (Connection data, input)16 mm²
Conductor cross section solid min. (Connection data, input)0.5 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 100 % (at 25 °C, non-condensing)
Conductor cross section solid max. (Connection data, output)1.5 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Standard - Electrical safety (Connection data for signaling)EN 60950-1/VDE 0805 (SELV)
Conductor cross section flexible max. (Connection data, input)16 mm²
Conductor cross section flexible min. (Connection data, input)0.5 mm²
Conductor cross section flexible max. (Connection data, output)1.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Protection against overvoltage at the output (OVP) (Input data)≤ 30 V DC
Standard – Safety extra-low voltage (Connection data for signaling)IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment (Connection data for signaling)EN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling)EN 50178/VDE 0160 (PELV)

Product Description

Active single QUINT redundancy module for rail mounting, protective varnish, 12 to 24 V DC input, 12 to 24 V DC / 1 x 40 A output, including universal adapter for UTA 107/30 rail mounted
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Block diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top