Service time: Monday to Friday 9:00-18:00
QUINT4-PS/3AC/24DC/40 - QUINT4-PS/3AC/24DC/40 2904623 PHOENIX CONTACT Primary-switched QUINT POWER power supply with free choice of ..
In Stock Hot Product

QUINT4-PS/3AC/24DC/40

QUINT4-PS/3AC/24DC/40 2904623 PHOENIX CONTACT Primary-switched QUINT POWER power supply with free choice of ..

$0.00USD
3549 in stock
Key Specifications
GTIN:4055626356105
Orderkey:2904623
(Drawings):
(Standards):CSA-C22.2 No. 107.1-01
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626356105
Orderkey2904623
(Drawings)
(Standards)CSA-C22.2 No. 107.1-01
Catalog pagePage 237 (C-4-2019)
Packing unit1 pc
(Input data)< 45 W (480 V AC)
(Output data)> 236000 h (60 °C)
CSA (Standards)CAN/CSA-C22.2 No. 60950-1-07
SIQ (Standards)BG (type approved)
Depth (Drawings)125 mm
Width (Drawings)120 mm
Country of originTH (Thailand)
ETIM 5.0 (eCl@ss)EC002540
ETIM 6.0 (eCl@ss)EC002540
ETIM 7.0 (eCl@ss)EC002540
Height (Drawings)130 mm
IECEx (Standards)Ex nA nC IIC T4 Gc (IECEx EPS 16.0057X)
Diagram (Drawings)
Custom tariff number85044030
(Ambient conditions)typ. 28 ms (3x 480 V AC)
REACh SVHC (EMC data)Lead 7439-92-1
(Conformance/approvals)4 kV (Test Level 4 - asymmetrical)
Block diagram (Drawings)
Efficiency (Output data)typ. 95.7 % (400 V AC)
Net weight (Output data)2.6 kg
UL approvals (Standards)UL Listed UL 508
Output power (Input data)960 W
Stripping length (General)8 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Screw connection
Residual ripple (Input data)< 50 mVPP(with nominal values)
eCl@ss 8.0 (Classifications)27049002
eCl@ss 9.0 (Classifications)27040701
I/O/S (Conformance/approvals)asymmetrical
Input (Conformance/approvals)2 kV (Test Level 4 - symmetrical)
Control deviation (Input data)< 0.5 % (Static load change 10 % ... 90 %)
Output (Conformance/approvals)1 kV (Test Level 3 - symmetrical)
Protection class (Output data)I
Signal (Conformance/approvals)1 kV (Test Level 2 - asymmetrical)
Flicker (Conformance/approvals)EN 61000-3-3
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
Voltage (Conformance/approvals)2.5 kV
(Connection data for signaling)IEC 62236-5
Comments (Conformance/approvals)Criterion A
Degree of pollution (Dimensions)2
Installation height (Dimensions)≤ 5000 m (> 2000 m, observe derating)
Connection in series (Input data)yes
Degree of protection (Dimensions)IP20
Frequency (Conformance/approvals)50 Hz
Shipbuilding approval (Standards)DNV GL applied for
Degree of protection (Output data)IP20
Typical response time (Input data)300 ms (from SLEEP MODE)
Connection in parallel (Input data)Yes, for redundancy and increased capacity
Criterion A (Conformance/approvals)Normal operating behavior within the specified limits.
Criterion B (Conformance/approvals)Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C (Conformance/approvals)Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Inrush current (Ambient conditions)typ. 1.5 A (at 25 °C)
Nominal output voltage (Input data)24 V DC
Voltage dip (Conformance/approvals)0 %
Test level 1 (Conformance/approvals)15 Hz 150 Hz (Test Level 4)
Test level 2 (Conformance/approvals)150 Hz 1.5 kHz (Test Level 4)
Test level 3 (Conformance/approvals)1.5 kHz 15 kHz (Test Level 4)
Test level 4 (Conformance/approvals)15 kHz 150 kHz (Test Level 4)
Test level 5 (Conformance/approvals)16.7 Hz 50 Hz 60 Hz (Test Level 4)
Test level 6 (Conformance/approvals)16.7 Hz 50 Hz 60 Hz (Test Level 4)
Voltage dips (Conformance/approvals)EN 61000-4-11
Weight per Piece (excluding packing)2,780.000 g
Noise emission (Conformance/approvals)EN 55016
Additional text (Conformance/approvals)Test Level 2
Dynamic Boost (IDyn.Boost) (Input data)60 A (5 s)
Frequency range (Conformance/approvals)0.15 MHz ... 80 MHz
Static Boost (IStat.Boost) (Input data)45 A
Type of protection (Ambient conditions)Transient surge protection
Current consumption (Ambient conditions)3x 1.8 A (400 V AC)
Discharge in air (Conformance/approvals)15 kV (Test Level 4)
Feedback voltage resistance (Input data)≤ 35 V DC
Input voltage range (Ambient conditions)3x 400 V AC ... 500 V AC -20 % ... +10 %
MTBF (IEC 61709, SN 29500) (Output data)> 849000 h (25 °C)
Nominal output current (IN) (Input data)40 A
Contact discharge (Conformance/approvals)8 kV (Test Level 4)
Frequency range (fN) (Ambient conditions)50 Hz ... 60 Hz -10 % ... +10 %
Harmonic currents (Conformance/approvals)EN 61000-3-2
Mains buffering time (Ambient conditions)typ. 28 ms (3x 400 V AC)
Number of periods (Conformance/approvals)0,5 / 1 / 5 / 50 / 250 periods
Power loss nominal load max. (Input data)< 45 W (400 V AC)
Stripping length (Connection data, input)10 mm
Conductor cross section AWG max. (General)10
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Screw connection
Stripping length (Connection data, output)8 mm
Connection method (Connection data, output)Push-in connection
Insulation voltage input / PE (Output data)3.5 kV AC (type test)
Power factor (cos phi) (Ambient conditions)0.91
Selective Fuse Breaking (ISFB) (Input data)215 A (15 ms)
Test field strength (Conformance/approvals)110 A/m
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)6 mm²
Conductor cross section solid min. (General)0.2 mm²
Discharge current to PE (Ambient conditions)< 3.5 mA
Insulation voltage output / PE (Output data)0.5 kV DC (type test)
Insulation voltage input/output (Output data)4 kV AC (type test)
Low Voltage Directive (Conformance/approvals)Conformance with Low Voltage Directive 2014/35/EC
Nominal power consumption (Ambient conditions)1217 VA
Conductor cross section flexible max. (General)4 mm²
Conductor cross section flexible min. (General)0.2 mm²
DNV GL noise radiation (Conformance/approvals)Class B
Electrostatic discharge (Conformance/approvals)EN 61000-4-2
Fast transients (burst) (Conformance/approvals)EN 61000-4-4
Signals (test level 1) (Conformance/approvals)100 kHz 1 MHz (Test Level 3 - symmetrical)
Signals (test level 2) (Conformance/approvals)100 kHz 1 MHz (Test Level 3 - asymmetrical)
Conducted noise emission (Conformance/approvals)EN 55016
Electromagnetic HF field (Conformance/approvals)EN 61000-4-3
Nominal input voltage range (Ambient conditions)3x 400 V AC ... 500 V AC
Protective circuit/component (Ambient conditions)Varistor, gas-filled surge arrester
Rail applications (Connection data for signaling)EN 50121-5
Pulse-shape magnetic field (Conformance/approvals)EN 61000-4-9
Surge voltage load (surge) (Conformance/approvals)EN 61000-4-5
Attenuated oscillating wave (Conformance/approvals)EN 61000-4-18
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Electromagnetic compatibility (Conformance/approvals)Conformance with EMC Directive 2014/30/EU
Input, output (test level 1) (Conformance/approvals)100 kHz 1 MHz (Test Level 3 - asymmetrical)
Input, output (test level 2) (Conformance/approvals)10 MHz
DNV GL conducted interference (Conformance/approvals)Class A
Ambient temperature (start-up type tested) (Dimensions)-40 °C
Setting range of the output voltage (USet) (Input data)24 V DC ... 29.5 V DC (constant capacity)
Conductor cross section AWG max. (Connection data, input)6
Conductor cross section AWG min. (Connection data, input)20
Damped oscillating magnetic field (Conformance/approvals)EN 61000-4-10
Conductor cross section AWG max. (Connection data, output)16
Conductor cross section AWG min. (Connection data, output)24
Conductor cross section solid max. (Connection data, input)16 mm²
Conductor cross section solid min. (Connection data, input)0.5 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)< 5 W (400 V AC)
Conductor cross section solid max. (Connection data, output)1 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Mains variation/undervoltage (Connection data for signaling)SEMI F47-0706; EN 61000-4-11
Standard - Electrical safety (Connection data for signaling)IEC 60950-1/VDE 0805 (SELV)
EMC requirements, power plant (Connection data for signaling)IEC 61850-3
Recommended breaker for input protection (Ambient conditions)3x 4 A ... 20 A (Characteristic B, C, D, K or comparable)
Conductor cross section flexible max. (Connection data, input)16 mm²
Conductor cross section flexible min. (Connection data, input)0.5 mm²
Conductor cross section flexible max. (Connection data, output)1.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Protection against overvoltage at the output (OVP) (Input data)≤ 32 V DC
Standard - Safety of transformers (Connection data for signaling)EN 61558-2-16
EMC requirements for noise immunity (Connection data for signaling)EN 61000-6-1
Asymmetrical conducted disturbance variables (Conformance/approvals)EN 61000-4-16
Standard – Safety extra-low voltage (Connection data for signaling)IEC 60950-1 (SELV)
Attenuated sinusoidal oscillations (ring wave) (Conformance/approvals)EN 61000-4-12
Standard – Limitation of mains harmonic currents (Connection data for signaling)EN 61000-3-2
HART FSK Physical Layer Test Specification Compliance (Connection data for signaling)Output voltage UOutcompliant
Standard - safety for equipment for measurement, control, and laboratory use (Connection data for signaling)IEC 61010-1
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling)EN 50178/VDE 0160 (PELV)

Product Description

Primary-switched QUINT POWER power supply with selectable output characteristic curve, SFB (Selective Fuse Breaking) technology and NFC interface, input: three-phase, output: 24 V DC / 40 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Block diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top