Service time: Monday to Friday 9:00-18:00
QUINT4-PS/1AC/24DC/20 - QUINT4-PS/1AC/24DC/20 2904602 PHOENIX CONTACT Power supply unit
In Stock Hot Product

QUINT4-PS/1AC/24DC/20

QUINT4-PS/1AC/24DC/20 2904602 PHOENIX CONTACT Power supply unit

$0.00USD
3456 in stock
Key Specifications
GTIN:4046356985352
Orderkey:2904602
Catalog page:Page 207 (C-4-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356985352
Orderkey2904602
Catalog pagePage 207 (C-4-2017)
Packing unit1 pc
(Input data)< 32 W (230 V AC)
(Output data)> 309000 h (60 °C)
Country of originTH (Thailand)
Custom tariff number85044030
(Ambient conditions)typ. 29 ms (230 V AC)
Derating (Input data)> 60 °C (2.5%/K)
Efficiency (Output data)typ. 92.4 % (120 V AC)
Net weight (Output data)1.3 kg
Output power (Input data)480 W
Stripping length (General)8 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Screw connection
Depth (Key Commercial Data)125 mm
Width (Key Commercial Data)70 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)130 mm
Residual ripple (Input data)< 50 mVPP(with nominal values)
Control deviation (Input data)< 0.5 % (Static load change 10 % ... 90 %)
Protection class (Output data)I
Input fuse (Ambient conditions)12 A (slow-blow, internal)
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
(Connection data for signaling)UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Degree of pollution (Dimensions)2
Feedback resistance (Input data)≤ 35 V DC
Installation height (Dimensions)≤ 5000 m (> 2000 m, observe derating)
Connection in series (Input data)yes
Degree of protection (Dimensions)IP20
Degree of protection (Output data)IP20
Typical response time (Input data)300 ms (from SLEEP MODE)
Assembly instructions (Output data)alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Connection in parallel (Input data)Yes, for redundancy and increased capacity
Nominal output voltage (Input data)24 V DC
Mains buffering (Ambient conditions)typ. 28 ms (120 V AC)
Weight per Piece (excluding packing)1,593.000 g
Shock (Connection data for signaling)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
REACh SVHC (Standards and Regulations)Lead 7439-92-1
AC frequency range (Ambient conditions)50 Hz ... 60 Hz -10 % ... +10 %
Dynamic Boost (IDyn.Boost) (Input data)30 A (5 s)
Static Boost (IStat.Boost) (Input data)25 A
Type of protection (Ambient conditions)Transient surge protection
Voltage (Connection data for signaling)10 V (Test Level 3)
Comments (Connection data for signaling)Criterion B
Current consumption (Ambient conditions)6.8 A (100 V AC)
Input voltage range (Ambient conditions)100 V AC ... 240 V AC -15 % ... +10 %
MTBF (IEC 61709, SN 29500) (Output data)> 1110000 h (25 °C)
Nominal output current (IN) (Input data)20 A
Inrush surge current (Ambient conditions)typ. 11 A (at 25 °C)
Power loss nominal load max. (Input data)< 40 W (120 V AC)
Stripping length (Connection data, input)8 mm
Conductor cross section AWG max. (General)10
Conductor cross section AWG min. (General)30
Connection method (Connection data, input)Screw connection
Stripping length (Connection data, output)8 mm
Connection method (Connection data, output)Push-in connection
Insulation voltage input / PE (Output data)3.5 kV AC (type test)
Selective Fuse Breaking (ISFB) (Input data)120 A (15 ms)
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)6 mm²
Conductor cross section solid min. (General)0.2 mm²
Discharge current to PE (Ambient conditions)< 3.5 mA
Insulation voltage output / PE (Output data)0.5 kV DC (type test)
UL approvals (Connection data for signaling)UL Listed UL 508
Insulation voltage input/output (Output data)4 kV AC (type test)
Noise emission (Connection data for signaling)Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Noise immunity (Connection data for signaling)Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial), and EN 61000-6-5 (power station equipment zone), IEC/EN 61850-3 (energy supply)
Nominal power consumption (Ambient conditions)520 VA
Conductor cross section flexible max. (General)4 mm²
Conductor cross section flexible min. (General)0.2 mm²
Frequency range (Connection data for signaling)0.15 MHz ... 80 MHz
Dielectric strength maximum (Ambient conditions)300 V AC 60 s
Nominal input voltage range (Ambient conditions)100 V AC ... 240 V AC
Contact discharge (Connection data for signaling)4 kV (Test Level 2)
Protective circuit/component (Ambient conditions)Varistor, gas-filled surge arrester
Rail applications (Connection data for signaling)EN 50121-3-2
Test field strength (Connection data for signaling)3 V/m (Test Level 2)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Depth with alternative assembly (Key Commercial Data)73 mm
Low Voltage Directive (Connection data for signaling)Conformance with Low Voltage Directive 2014/35/EC
Shipbuilding approval (Connection data for signaling)DNV GL, PRS, BV, LR, ABS
Standards/regulations (Connection data for signaling)EN 61000-4-8
Vibration (operation) (Connection data for signaling)5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
Width with alternative assembly (Key Commercial Data)122 mm
Height with alternative assembly (Key Commercial Data)130 mm
Ambient temperature (start-up type tested) (Dimensions)-40 °C
Setting range of the output voltage (USet) (Input data)24 V DC ... 29.5 V DC (constant capacity)
Choice of suitable circuit breakers (Ambient conditions)10 A ... 16 A (Characteristic B, C, D, K or comparable)
Conducted noise emission (Connection data for signaling)EN 55016 EN 61000-6-4 (Class A)
Conductor cross section AWG max. (Connection data, input)10
Conductor cross section AWG min. (Connection data, input)30
Standard - Safe isolation (Connection data for signaling)DIN VDE 0100-410
Conductor cross section AWG max. (Connection data, output)16
Conductor cross section AWG min. (Connection data, output)24
Conductor cross section solid max. (Connection data, input)6 mm²
Conductor cross section solid min. (Connection data, input)0.2 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)< 5 W (120 V AC)
Protection against surge voltage on the output (Input data)≤ 32 V DC
Conductor cross section solid max. (Connection data, output)1.5 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Standard - Electrical safety (Connection data for signaling)IEC 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Connection data for signaling)Conformance with EMC Directive 2014/30/EU
Conductor cross section flexible max. (Connection data, input)4 mm²
Conductor cross section flexible min. (Connection data, input)0.2 mm²
Conductor cross section flexible max. (Connection data, output)1.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Overvoltage category (EN 60950-1) (Connection data for signaling)II (≤ 5000 m)
Overvoltage category (EN 61010-1) (Connection data for signaling)II (≤ 5000 m)
Overvoltage category (EN 62477-1) (Connection data for signaling)III (≤ 2000 m)
Standard - Safety of transformers (Connection data for signaling)EN 61558-2-16 (air clearances and creepage distances only)
Standard – Safety extra-low voltage (Connection data for signaling)IEC 60950-1 (SELV)
Standard – Limitation of mains harmonic currents (Connection data for signaling)EN 61000-3-2
Standard - power supply devices for low voltage with DC output (Connection data for signaling)EN 61204-3
Approval - requirement of the semiconductor industry with regard to mains voltage dips (Connection data for signaling)SEMI F47-0706; EN 61000-4-11
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling)EN 50178/VDE 0160 (PELV)

Product Description

QUINT POWER switched primary power supply with selectable output characteristic curve, SFB (Selective Fuse Breaking) technology and NFC interface, input: single-phase, output: 24VDC/20 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top