Service time: Monday to Friday 9:00-18:00
QUINT4-PS/1AC/24DC/2.5/SC - QUINT4-PS/1AC/24DC/2.5/SC 2904598 PHOENIX CONTACT Power supply unit
In Stock Hot Product

QUINT4-PS/1AC/24DC/2.5/SC

QUINT4-PS/1AC/24DC/2.5/SC 2904598 PHOENIX CONTACT Power supply unit

$0.00USD
4606 in stock
Key Specifications
GTIN:4055626156040
Orderkey:2904598
Packing unit:1 pc
(Input data):< 5 W (120 V AC)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626156040
Orderkey2904598
Packing unit1 pc
(Input data)< 5 W (120 V AC)
(Output data)> 295000 h (60 °C)
Country of originDE (Germany)
Custom tariff number85044030
(Ambient conditions)typ. 54 ms (230 V AC)
Derating (Input data)> 60 °C (2.5%/K)
Efficiency (Output data)typ. 91.9 % (120 V AC)
Net weight (Output data)0.244 kg
Output power (Input data)60 W
Stripping length (General)8 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Screw connection
Depth (Key Commercial Data)90 mm
Width (Key Commercial Data)32 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)99 mm
Residual ripple (Input data)< 40 mVPP(with nominal values)
Control deviation (Input data)< 0.5 % (Static load change 10 % ... 90 %)
Protection class (Output data)II
Input fuse (Ambient conditions)3.15 A (slow-blow, internal)
(Connection data for signaling)ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Degree of pollution (Dimensions)2
Feedback resistance (Input data)≤ 35 V DC
Installation height (Dimensions)≤ 5000 m (> 2000 m, observe derating)
Connection in series (Input data)yes
Degree of protection (Dimensions)IP20
Degree of protection (Output data)IP20
Typical response time (Input data)500 ms
Assembly instructions (Output data)DIN rail mounting
Connection in parallel (Input data)Yes, for redundancy and increased capacity
Nominal output voltage (Input data)24 V DC
Mains buffering (Ambient conditions)typ. 54 ms (120 V AC)
Weight per Piece (excluding packing)313.100 g
Shock (Connection data for signaling)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
Dynamic Boost (IDyn.Boost) (Input data)5 A (≤60 °C (5 s), Input <150 V AC Derating 0.5 %/V)
Static Boost (IStat.Boost) (Input data)3.125 A (≤ 40 °C)
Type of protection (Ambient conditions)Transient surge protection
Voltage (Connection data for signaling)10 V (Test Level 3)
Comments (Connection data for signaling)Criterion B
Current consumption (Ambient conditions)0.85 A (100 V AC)
Input voltage range (Ambient conditions)100 V AC ... 240 V AC -15 % ... +10 %
MTBF (IEC 61709, SN 29500) (Output data)> 1347000 h (25 °C)
Nominal output current (IN) (Input data)2.5 A
Inrush surge current (Ambient conditions)typ. 10 A (at 25 °C)
Power loss nominal load max. (Input data)< 5 W (230 V AC)
Stripping length (Connection data, input)8 mm
Conductor cross section AWG max. (General)14
Conductor cross section AWG min. (General)26
Connection method (Connection data, input)Screw connection
Stripping length (Connection data, output)8 mm
Connection method (Connection data, output)Screw connection
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.14 mm²
Discharge current to PE (Ambient conditions)< 0.25 mA (264 V AC, 60 Hz)
UL approvals (Connection data for signaling)UL Listed UL 61010-1
Insulation voltage input/output (Output data)4 kV AC (type test)
Nominal power consumption (Ambient conditions)71 VA
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.14 mm²
Frequency range (Connection data for signaling)0.15 MHz ... 80 MHz
Dielectric strength maximum (Ambient conditions)300 V AC 30 s
Contact discharge (Connection data for signaling)4 kV (Test Level 2)
Protective circuit/component (Ambient conditions)Varistor
Test field strength (Connection data for signaling)3 V/m (Test Level 2)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Standards/regulations (Connection data for signaling)EN 61000-4-8
Vibration (operation) (Connection data for signaling)< 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)
Ambient temperature (start-up type tested) (Dimensions)-40 °C
Setting range of the output voltage (USet) (Input data)24 V DC ... 28 V DC (constant capacity)
Choice of suitable circuit breakers (Ambient conditions)6 A ... 16 A (Characteristic B, C or comparable)
Conducted noise emission (Connection data for signaling)EN 55016 EN 61000-6-4 (Class A)
Conductor cross section AWG max. (Connection data, input)14
Conductor cross section AWG min. (Connection data, input)26
Standard - Safe isolation (Connection data for signaling)IEC 61558-2-16
Conductor cross section AWG max. (Connection data, output)14
Conductor cross section AWG min. (Connection data, output)26
Conductor cross section solid max. (Connection data, input)2.5 mm²
Conductor cross section solid min. (Connection data, input)0.14 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)< 1 W (230 V AC)
Protection against surge voltage on the output (Input data)≤ 32 V DC
Conductor cross section solid max. (Connection data, output)2.5 mm²
Conductor cross section solid min. (Connection data, output)0.14 mm²
Standard - Electrical safety (Connection data for signaling)IEC 61010-2-201 (SELV)
Electromagnetic compatibility (Connection data for signaling)Conformance with EMC Directive 2014/30/EU
Conductor cross section flexible max. (Connection data, input)2.5 mm²
Conductor cross section flexible min. (Connection data, input)0.14 mm²
Conductor cross section flexible max. (Connection data, output)2.5 mm²
Conductor cross section flexible min. (Connection data, output)0.14 mm²
Overvoltage category (EN 61010-1) (Connection data for signaling)II (≤ 5000 m)
Overvoltage category (EN 62477-1) (Connection data for signaling)III (≤ 2000 m)
Standard - Safety of transformers (Connection data for signaling)EN 61558-2-16
Standard – Safety extra-low voltage (Connection data for signaling)IEC 61010-1 (SELV)
Standard – Limitation of mains harmonic currents (Connection data for signaling)EN 61000-3-2
Standard - power supply devices for low voltage with DC output (Connection data for signaling)EN 61204-3

Product Description

QUINT POWER primary switching power supplies, Screw connection, Rail mounting, input:1phase, output: 24 VDC / 2.5 A. Alternative item: 2909576
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top