| Parameter | Value |
|---|---|
| GTIN | 4055626356495 |
| Orderkey | 2909576 |
| Packing unit | 1 pc |
| (Input data) | < 5 W (120 V AC) |
| (Output data) | > 295000 h (60 °C) |
| Country of origin | DE (Germany) |
| Custom tariff number | 85044030 |
| (Ambient conditions) | typ. 54 ms (230 V AC) |
| Derating (Input data) | > 60 °C (2.5%/K) |
| Efficiency (Output data) | typ. 91.9 % (120 V AC) |
| Net weight (Output data) | 0.244 kg |
| Output power (Input data) | 60 W |
| Stripping length (General) | 10 mm |
| Climatic class (Dimensions) | 3K3 (in acc. with EN 60721) |
| Connection method (General) | Push-in technology |
| Depth (Key Commercial Data) | 90 mm |
| Width (Key Commercial Data) | 32 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 106 mm |
| Residual ripple (Input data) | < 40 mVPP(with nominal values) |
| Control deviation (Input data) | < 0.5 % (Static load change 10 % ... 90 %) |
| Protection class (Output data) | II |
| Input fuse (Ambient conditions) | 3.15 A (slow-blow, internal) |
| (Connection data for signaling) | ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
| Degree of pollution (Dimensions) | 2 |
| Feedback resistance (Input data) | ≤ 35 V DC |
| Installation height (Dimensions) | ≤ 5000 m (> 2000 m, observe derating) |
| Connection in series (Input data) | yes |
| Degree of protection (Dimensions) | IP20 |
| Degree of protection (Output data) | IP20 |
| Typical response time (Input data) | 500 ms |
| Assembly instructions (Output data) | DIN rail mounting |
| Connection in parallel (Input data) | Yes, for redundancy and increased capacity |
| Nominal output voltage (Input data) | 24 V DC |
| Mains buffering (Ambient conditions) | typ. 54 ms (120 V AC) |
| Weight per Piece (excluding packing) | 311.100 g |
| Shock (Connection data for signaling) | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 25; |
| Dynamic Boost (IDyn.Boost) (Input data) | 5 A (≤60 °C (5 s), Input <150 V AC Derating 0.5 %/V) |
| Static Boost (IStat.Boost) (Input data) | 3.125 A (≤ 40 °C) |
| Type of protection (Ambient conditions) | Transient surge protection |
| Voltage (Connection data for signaling) | 10 V (Test Level 3) |
| Comments (Connection data for signaling) | Criterion B |
| Current consumption (Ambient conditions) | 0.85 A (100 V AC) |
| Input voltage range (Ambient conditions) | 100 V AC ... 240 V AC -15 % ... +10 % |
| MTBF (IEC 61709, SN 29500) (Output data) | > 1347000 h (25 °C) |
| Nominal output current (IN) (Input data) | 2.5 A |
| Inrush surge current (Ambient conditions) | typ. 10 A (at 25 °C) |
| Power loss nominal load max. (Input data) | < 5 W (230 V AC) |
| Stripping length (Connection data, input) | 10 mm |
| Conductor cross section AWG max. (General) | 14 |
| Conductor cross section AWG min. (General) | 24 |
| Connection method (Connection data, input) | Push-in technology |
| Stripping length (Connection data, output) | 10 mm |
| Connection method (Connection data, output) | Push-in technology |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Conductor cross section solid max. (General) | 2.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| Discharge current to PE (Ambient conditions) | < 0.25 mA (264 V AC, 60 Hz) |
| UL approvals (Connection data for signaling) | UL Listed UL 61010-1 |
| Insulation voltage input/output (Output data) | 4 kV AC (type test) |
| Nominal power consumption (Ambient conditions) | 71 VA |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Frequency range (Connection data for signaling) | 0.15 MHz ... 80 MHz |
| Dielectric strength maximum (Ambient conditions) | 300 V AC 30 s |
| Contact discharge (Connection data for signaling) | 4 kV (Test Level 2) |
| Protective circuit/component (Ambient conditions) | Varistor |
| Test field strength (Connection data for signaling) | 3 V/m (Test Level 2) |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Standards/regulations (Connection data for signaling) | EN 61000-4-8 |
| Vibration (operation) (Connection data for signaling) | < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6) |
| Ambient temperature (start-up type tested) (Dimensions) | -40 °C |
| Setting range of the output voltage (USet) (Input data) | 24 V DC ... 28 V DC (constant capacity) |
| Conducted noise emission (Connection data for signaling) | EN 55016 EN 61000-6-4 (Class A) |
| Conductor cross section AWG max. (Connection data, input) | 14 |
| Conductor cross section AWG min. (Connection data, input) | 24 |
| Standard - Safe isolation (Connection data for signaling) | IEC 61558-2-16 |
| Conductor cross section AWG max. (Connection data, output) | 14 |
| Conductor cross section AWG min. (Connection data, output) | 24 |
| Conductor cross section solid max. (Connection data, input) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, input) | 0.2 mm² |
| Max. permissible relative humidity (operation) (Dimensions) | ≤ 95 % (at 25 °C, non-condensing) |
| Maximum power dissipation in no-load condition (Input data) | < 1 W (230 V AC) |
| Protection against surge voltage on the output (Input data) | ≤ 32 V DC |
| Conductor cross section solid max. (Connection data, output) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, output) | 0.2 mm² |
| Standard - Electrical safety (Connection data for signaling) | IEC 61010-2-201 (SELV) |
| Electromagnetic compatibility (Connection data for signaling) | Conformance with EMC Directive 2014/30/EU |
| Conductor cross section flexible max. (Connection data, input) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, input) | 0.2 mm² |
| Conductor cross section flexible max. (Connection data, output) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, output) | 0.2 mm² |
| Overvoltage category (EN 61010-1) (Connection data for signaling) | II |
| Overvoltage category (EN 62477-1) (Connection data for signaling) | III (≤ 2000 m) |
| Standard - Safety of transformers (Connection data for signaling) | EN 61558-2-16 |
| Standard – Safety extra-low voltage (Connection data for signaling) | IEC 61010-1 (SELV) |
| Standard – Limitation of mains harmonic currents (Connection data for signaling) | EN 61000-3-2 |
| Standard - power supply devices for low voltage with DC output (Connection data for signaling) | EN 61204-3 |
Technical specifications and performance data
Installation and operation guide