| Parameter | Value |
|---|---|
| GTIN | 4046356554183 |
| Orderkey | 2320267 |
| Catalog page | Page 294 (C-4-2017) |
| Packing unit | 1 pc |
| Country of origin | CN (China) |
| Custom tariff number | 85371091 |
| Screw thread (General) | M4 |
| Stripping length (General) | 7 mm |
| Climatic class (Dimensions) | 3K3 (in acc. with EN 60721) |
| Connection method (General) | Pluggable screw connection |
| Depth (Key Commercial Data) | 125 mm |
| Width (Key Commercial Data) | 120 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 169 mm |
| Disposal (General output data) | Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations. They can also be returned to Phoenix Contact or the manufacturer. |
| (Connection data for signaling) | 15 Hz ... 150 Hz, 2.3g tv= 90 min. |
| Degree of pollution (Dimensions) | 2 |
| Net weight (General output data) | 3.8 kg |
| Degree of protection (Dimensions) | IP20 |
| POWER BOOST (IBoost) (Input data) | 15 A (0 °C ... 40 °C) |
| Input voltage (Ambient conditions) | 24 V DC |
| IQ technology (General output data) | Yes |
| Memory medium (General output data) | Lead rechargeable battery module, 3.4 Ah |
| Nominal output voltage (Input data) | 24 V DC |
| Weight per Piece (excluding packing) | 4,434.000 g |
| Screw thread (Connection data, input) | M4 |
| Shock (Connection data for signaling) | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 3 |
| Protection class (General output data) | III |
| Screw thread (Connection data, output) | M4 |
| Mounting position (General output data) | horizontal DIN rail NS 35, EN 60715 |
| Voltage (Connection data for signaling) | 10 V (Test Level 3) |
| Comments (Connection data for signaling) | Criterion B |
| Input voltage range (Ambient conditions) | 18 V DC ... 30 V DC |
| Nominal output current (IN) (Input data) | 10 A (0 °C ... 40 °C) |
| Stripping length (Connection data, input) | 7 mm |
| Conductor cross section AWG max. (General) | 12 |
| Conductor cross section AWG min. (General) | 16 |
| Connection method (Connection data, input) | Pluggable screw connection |
| Assembly instructions (General output data) | alignable: horizontal 5 mm, vertical 50 mm |
| Selective Fuse Breaking (ISFB) (Input data) | 60 A (0 °C ... 40 °C) |
| Ambient temperature (operation) (Dimensions) | 0 °C ... 40 °C |
| Conductor cross section solid max. (General) | 2.5 mm² |
| Conductor cross section solid min. (General) | 0.2 mm² |
| UL approvals (Connection data for signaling) | UL/C-UL Recognized UL 60950-1 |
| Noise immunity (Connection data for signaling) | EN 61000-6-2:2005 |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.2 mm² |
| Current consumption (idle) (Ambient conditions) | 9.5 mA |
| Frequency range (Connection data for signaling) | 0.15 MHz ... 80 MHz |
| MTBF (IEC 61709, SN 29500) (General output data) | > 806000 h (40 °C) |
| Contact discharge (Connection data for signaling) | 4 kV (Test Level 2) |
| Rail applications (Connection data for signaling) | EN 50121-4 |
| Current consumption (maximum) (Ambient conditions) | 18.6 A (24 V DC) |
| Test field strength (Connection data for signaling) | 3 V/m (Criterion A) |
| Ambient temperature (storage/transport) (Dimensions) | -15 °C ... 40 °C |
| Efficiency (Output data (24 V DC battery operation)) | > 97.6 % (Mains operation, with charged energy storage) |
| Low Voltage Directive (Connection data for signaling) | Conformance with LV directive 2006/95/EC |
| Standards/regulations (Connection data for signaling) | EN 61000-6-3 |
| Vibration (operation) (Connection data for signaling) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| Conductor cross section AWG max. (Connection data, input) | 12 |
| Conductor cross section AWG min. (Connection data, input) | 16 |
| Conductor cross section AWG max. (Connection data, output) | 12 |
| Conductor cross section AWG min. (Connection data, output) | 24 |
| Conductor cross section solid max. (Connection data, input) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, input) | 0.2 mm² |
| Current consumption (charging process) (Ambient conditions) | 3.6 A |
| Max. permissible relative humidity (operation) (Dimensions) | ≤ 95 % (25 °C, non-condensing) |
| Conductor cross section solid max. (Connection data, output) | 2.5 mm² |
| Conductor cross section solid min. (Connection data, output) | 0.2 mm² |
| POWER BOOST (IBoost) (Output data (24 V DC mains operation)) | 15 A (0 °C ... 40 °C) |
| Standard - Electrical safety (Connection data for signaling) | EN 60950-1/VDE 0805 (SELV) |
| Electromagnetic compatibility (Connection data for signaling) | Conformance with EMC Directive 2014/30/EU |
| Conductor cross section flexible max. (Connection data, input) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, input) | 0.2 mm² |
| Nominal output voltage (Output data (24 V DC mains operation)) | 24 V DC |
| Conductor cross section flexible max. (Connection data, output) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, output) | 0.2 mm² |
| Connection in acc. with standard (Connection data for signaling) | CUL |
| Output voltage range (depends on the input voltage) (Input data) | 18 V DC ... 30 V DC |
| Nominal output current (IN) (Output data (24 V DC mains operation)) | 10 A (0 °C ... 40 °C) |
| Selective Fuse Breaking (ISFB) (Output data (24 V DC mains operation)) | 65 A (0 °C ... 40 °C) |
| Output voltage range (depends on the input voltage) (Output data (24 V DC mains operation)) | 19.2 V DC ... 27.6 V DC (UOUT= UBAT- 0.5 V DC) |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling) | EN 50178/VDE 0160 (PELV) |
Technical specifications and performance data
Installation and operation guide