Service time: Monday to Friday 9:00-18:00
QUINT-UPS/ 1AC/ 1AC/500VA - QUINT-UPS/ 1AC/ 1AC/500VA 2320270 PHOENIX CONTACT Uninterruptible power supply
In Stock Hot Product

QUINT-UPS/ 1AC/ 1AC/500VA

QUINT-UPS/ 1AC/ 1AC/500VA 2320270 PHOENIX CONTACT Uninterruptible power supply

$0.00USD
3090 in stock
Key Specifications
GTIN:4046356560078
Orderkey:2320270
Catalog page:Page 280 (C-4-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356560078
Orderkey2320270
Catalog pagePage 280 (C-4-2017)
Packing unit1 pc
(Input data)2.7 A (230 V AC, -25°C ... 40°C)
(Output data)
Country of originDE (Germany)
Custom tariff number85371091
(Ambient conditions)96 V AC ... 264 V AC
Derating (Input data)> 50 °C ... 70 °C (2.5%/K)
Screw thread (General)M4
Efficiency (Output data)> 98 % (Mains operation)
Net weight (Output data)2.2 kg
Stripping length (General)8 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Screw connection
Depth (Key Commercial Data)125 mm
IQ technology (Output data)Yes
Width (Key Commercial Data)125 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)130 mm
Protection class (Output data)I
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
(Connection data for signaling)15 Hz ... 150 Hz, 2.3g tv= 90 min.
Connection in series (Input data)No
Degree of protection (Dimensions)IP20
POWER BOOST (IBoost) (Input data)5.2 A (120 V AC, -25°C ... 40°C)
Buffer period (Ambient conditions)1 h (38 AH)
Degree of protection (Output data)IP20
Assembly instructions (Output data)alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Connection in parallel (Input data)no
Nominal output voltage (Input data)120 V AC
Weight per Piece (excluding packing)2,201.000 g
Screw thread (Connection data, input)M4
Shock (Connection data for signaling)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Screw thread (Connection data, output)M4
AC frequency range (Ambient conditions)45 Hz ... 65 Hz
Voltage (Connection data for signaling)10 V (Test Level 3)
Comments (Connection data for signaling)Criterion B
Input voltage range (Ambient conditions)184 V AC ... 264 V AC
MTBF (IEC 61709, SN 29500) (Output data)
Nominal output current (IN) (Input data)4.3 A (120 V AC, -25°C ... 50°C)
Stripping length (Connection data, input)8 mm
Conductor cross section AWG max. (General)10
Conductor cross section AWG min. (General)18
Connection method (Connection data, input)Screw connection
Nominal input voltage (Ambient conditions)240 V AC
Stripping length (Connection data, output)8 mm
Connection method (Connection data, output)Screw connection
Power factor (cos phi) (Ambient conditions)0.8
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 50 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)6 mm²
Conductor cross section solid min. (General)1.5 mm²
Permissible backup fuse (Ambient conditions)B16 230 V AC
UL approvals (Connection data for signaling)UL/C-UL Recognized UL 1778
Conductor cross section flexible max. (General)4 mm²
Conductor cross section flexible min. (General)1.5 mm²
Frequency range (Connection data for signaling)0.15 MHz ... 80 MHz
Contact discharge (Connection data for signaling)4 kV (Test Level 2)
Rail applications (Connection data for signaling)EN 50121-4
Test field strength (Connection data for signaling)3 V/m
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Standards/regulations (Connection data for signaling)EN 62040-2 (Class C1)
Vibration (operation) (Connection data for signaling)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Ambient temperature (start-up type tested) (Dimensions)-40 °C
Conductor cross section AWG max. (Connection data, input)10
Conductor cross section AWG min. (Connection data, input)18
Conductor cross section AWG max. (Connection data, output)10
Conductor cross section AWG min. (Connection data, output)24
Conductor cross section solid max. (Connection data, input)6 mm²
Conductor cross section solid min. (Connection data, input)1.5 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (25 °C, non-condensing)
Conductor cross section solid max. (Connection data, output)2.5 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Electromagnetic compatibility (Connection data for signaling)Conformance with EMC Directive 2014/30/EU
Conductor cross section flexible max. (Connection data, input)4 mm²
Conductor cross section flexible min. (Connection data, input)1.5 mm²
Conductor cross section flexible max. (Connection data, output)2.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Connection in acc. with standard (Connection data for signaling)CUL
Standard – Limitation of mains harmonic currents (Connection data for signaling)EN 61000-3-2 (Class A)

Product Description

Uninterruptible power supply with IQ 1CA/1CA/500 VA technology. For 120 V AC/230 V AC applications. It provides information at all times about the state of charge, residual life and service life of th
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top