Technical Specifications

ParameterValue
GTIN4017918927691
Orderkey2938219
(Signaling)UL/C-UL Recognized UL 60950-1
Catalog pagePage 567 (IF-2009)
Packing unit1 pc
(Output data)1.5 kV (routine test)
Country of originDE (Germany)
Custom tariff number85044030
(Ambient conditions)> 30 ms (480 V AC)
Derating (Input data)60 °C ... 70 °C (2.5%/K)
Screw thread (General)M3
Efficiency (Output data)> 90 % (for 230 V AC and nominal values)
Net weight (Output data)2.3 kg
UL approvals (Signaling)UL/C-UL listed UL 508
Output power (Input data)480 W
Noise emission (Signaling)EN 55011 (EN 55022)
Noise immunity (Signaling)EN 61000-6-2:2005
Stripping length (General)8 mm
Connection method (General)Screw connection
Depth (Key Commercial Data)125 mm
Width (Key Commercial Data)160 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)130 mm
Residual ripple (Input data)< 20 mVPP
Protection class (Output data)I (with PE connection)
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
Connection in series (Input data)yes
Degree of protection (Dimensions)IP20
Low Voltage Directive (Signaling)Conformance with LV directive 2006/95/EC
POWER BOOST (IBoost) (Input data)13 A (-25°C ... 40°C permanent )
Degree of protection (Output data)IP20
Typical response time (Input data)< 1 s
Assembly instructions (Output data)alignable: horizontally 0 mm, vertically 50 mm
Connection in parallel (Input data)Yes, for redundancy and increased capacity
Nominal output voltage (Input data)48 V DC ±1 %
Mains buffering (Ambient conditions)> 25 ms (400 V AC)
Weight per Piece (excluding packing)2,288.300 g
Output name (Connection data, output)DC OK floating
Screw thread (Connection data, input)M4
Standard - Safe isolation (Signaling)DIN VDE 0100-410
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Screw thread (Connection data, output)M4
AC frequency range (Ambient conditions)45 Hz ... 65 Hz
Frequency range DC (Ambient conditions)0 Hz
Standard - Equipment safety (Signaling)GS (tested safety)
Type of protection (Ambient conditions)Transient surge protection
Current consumption (Ambient conditions)approx. 3x 1.2 A (400 V AC)
Input voltage range (Ambient conditions)3x 320 V AC ... 575 V AC (for all three phases)
MTBF (IEC 61709, SN 29500) (Output data)> 500000 h
Nominal output current (IN) (Input data)10 A (-25 °C ... 60 °C)
Output voltage (Connection data, output)+ 24 V DC
Standard - Electrical safety (Signaling)EN 60950-1/VDE 0805 (SELV)
Status display (Connection data, output)"DC OK" LED green
Electromagnetic compatibility (Signaling)Conformance with EMC Directive 2014/30/EU
Inrush surge current (Ambient conditions)< 10 A
Power loss nominal load max. (Input data)45 W
Stripping length (Connection data, input)10 mm
Conductor cross section AWG max. (General)10
Conductor cross section AWG min. (General)24
Connection method (Connection data, input)Screw connection
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)2.5 mm²
Conductor cross section solid min. (General)0.2 mm²
Connection in acc. with standard (Signaling)CUL
Output description (Connection data, output)Relay contact, UOUT> 0.9 x UN: Contact closed
Insulation voltage input/output (Output data)3 kV (type test)
Standard - Safety of transformers (Signaling)EN 61558-2-17
Nominal power consumption (Ambient conditions)517 W
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Maximum inrush current (Connection data, output)max. 0.5 A
Nominal input voltage range (Ambient conditions)3x 400 V AC ... 500 V AC
Note on status display (Connection data, output)UOUT< 0.9 x UN: LED flashing
Continuous load current (Connection data, output)≤ 1 A
Peak switching voltages nominal load (Input data)< 140 mVPP(20 MHz)
Protective circuit/component (Ambient conditions)Varistor
Maximum switching voltage (Connection data, output)≤ 30 V AC/DC
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Depth with alternative assembly (Key Commercial Data)163 mm
Width with alternative assembly (Key Commercial Data)122 mm
Height with alternative assembly (Key Commercial Data)130 mm
Setting range of the output voltage (USet) (Input data)30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
Choice of suitable circuit breakers (Ambient conditions)3x 6 A ... 16 A (Characteristics B, C, D, K)
Conductor cross section AWG max. (Connection data, input)6
Conductor cross section AWG min. (Connection data, input)20
Conductor cross section AWG max. (Connection data, output)6
Conductor cross section AWG min. (Connection data, output)20
Conductor cross section solid max. (Connection data, input)16 mm²
Conductor cross section solid min. (Connection data, input)0.5 mm²
Max. permissible relative humidity (operation) (Dimensions)95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)10 W
Conductor cross section solid max. (Connection data, output)16 mm²
Conductor cross section solid min. (Connection data, output)0.5 mm²
Conductor cross section flexible max. (Connection data, input)10 mm²
Conductor cross section flexible min. (Connection data, input)0.5 mm²
Standard – Limitation of mains harmonic currents (Signaling)EN 61000-3-2
Conductor cross section flexible max. (Connection data, output)10 mm²
Conductor cross section flexible min. (Connection data, output)0.5 mm²
Information technology equipment - safety (CB scheme) (Signaling)CB Scheme
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Signaling)EN 50178/VDE 0160 (PELV)

Product Description

Symmetrical rail power supply, 48 V DC/ 10 A, primary switched, three-phase
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top