Technical Specifications

ParameterValue
GTIN4046356547734
Orderkey2320827
Catalog pagePage 214 (C-4-2017)
Packing unit1 pc
(Input data)< 0.1 % (change in input voltage ±10 %)
(Output data)
Country of originTH (Thailand)
Custom tariff number85044030
(Ambient conditions)typ. 35 ms (500 V AC)
Derating (Input data)60 °C ... 70 °C (2.5%/K)
Screw thread (General)M3
Efficiency (Output data)> 93 % (at 400 V AC and nominal values)
Net weight (Output data)2.5 kg
Output power (Input data)960 W
Stripping length (General)7 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Screw connection
Depth (Key Commercial Data)179 mm
Width (Key Commercial Data)96 mm
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Height (Key Commercial Data)130 mm
Residual ripple (Input data)< 50 mVPP(with nominal values)
Control deviation (Input data)< 1 % (change in load, static 10 % ... 90 %)
Protection class (Output data)I
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
(Connection data for signaling)15 Hz ... 150 Hz, 2.3g, 90 min.
Degree of pollution (Dimensions)2
Feedback resistance (Input data)max. 60 V DC
Installation height (Dimensions)4000 m
Connection in series (Input data)yes
Degree of protection (Dimensions)IP20
POWER BOOST (IBoost) (Input data)22.5 A (-25°C ... 40°C permanent, UOUT= 48 V DC )
Degree of protection (Output data)IP20
Typical response time (Input data)< 1 s
Assembly instructions (Output data)alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Connection in parallel (Input data)Yes, for redundancy and increased capacity
Nominal output voltage (Input data)48 V DC ±1 %
Mains buffering (Ambient conditions)typ. 25 ms (400 V AC)
Weight per Piece (excluding packing)2,500.000 g
Screw thread (Connection data, input)M3
Shock (Connection data for signaling)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Active current limitation (Input data)Approx. IBOOST= 22.5 A (for short-circuit)
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 25;
Screw thread (Connection data, output)M3
AC frequency range (Ambient conditions)45 Hz ... 65 Hz
Frequency range DC (Ambient conditions)0 Hz
Type of protection (Ambient conditions)Transient surge protection
Voltage (Connection data for signaling)10 V (Test Level 3)
Comments (Connection data for signaling)Criterion B
Current consumption (Ambient conditions)3x 2.1 A (400 V AC)
Input voltage range (Ambient conditions)3x 320 V AC ... 575 V AC
MTBF (IEC 61709, SN 29500) (Output data)> 890000 h (25 °C)
Nominal output current (IN) (Input data)20 A (-25 °C ... 60 °C, UOUT= 48 V DC)
Inrush surge current (Ambient conditions)< 20 A (typical)
Power loss nominal load max. (Input data)70 W
Stripping length (Connection data, input)10 mm
Conductor cross section AWG max. (General)10
Conductor cross section AWG min. (General)18
Connection method (Connection data, input)Screw connection
Output overvoltage protection (Input data)< 60 V DC
Insulation voltage input / PE (Output data)3.5 kV AC (type test)
Selective Fuse Breaking (ISFB) (Input data)100 A (12 ms)
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)6 mm²
Conductor cross section solid min. (General)0.2 mm²
Discharge current to PE (Ambient conditions)< 3.5 mA
Insulation voltage output / PE (Output data)500 V DC (routine test)
UL approvals (Connection data for signaling)UL Listed UL 508
Insulation voltage input/output (Output data)4 kV AC (type test)
Noise immunity (Connection data for signaling)EN 61000-6-2:2005
Nominal power consumption (Ambient conditions)1386 VA
Conductor cross section flexible max. (General)4 mm²
Conductor cross section flexible min. (General)0.2 mm²
Frequency range (Connection data for signaling)0.15 MHz ... 80 MHz
Nominal input voltage range (Ambient conditions)3x 400 V AC ... 500 V AC
Contact discharge (Connection data for signaling)4 kV (Test Level 2)
Protective circuit/component (Ambient conditions)Varistor
Rail applications (Connection data for signaling)EN 50121-4
Test field strength (Connection data for signaling)3 V/m (Test Level 2)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Depth with alternative assembly (Key Commercial Data)99 mm
Low Voltage Directive (Connection data for signaling)Conformance with LV directive 2006/95/EC
Standards/regulations (Connection data for signaling)EN 61000-4-6
Vibration (operation) (Connection data for signaling)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Width with alternative assembly (Key Commercial Data)176 mm
Height with alternative assembly (Key Commercial Data)130 mm
Ambient temperature (start-up type tested) (Dimensions)-40 °C
Setting range of the output voltage (USet) (Input data)30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
Choice of suitable circuit breakers (Ambient conditions)6 A ... 16 A (AC: Characteristics B, C, D, K)
Conductor cross section AWG max. (Connection data, input)6
Conductor cross section AWG min. (Connection data, input)8
Standard - Safe isolation (Connection data for signaling)DIN VDE 0100-410
Conductor cross section AWG max. (Connection data, output)10
Conductor cross section AWG min. (Connection data, output)18
Conductor cross section solid max. (Connection data, input)16 mm²
Conductor cross section solid min. (Connection data, input)0.5 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 95 % (at 25 °C, non-condensing)
Maximum power dissipation in no-load condition (Input data)24 W
Standard - Equipment safety (Connection data for signaling)BG (design tested)
Conductor cross section solid max. (Connection data, output)6 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Standard - Electrical safety (Connection data for signaling)IEC 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Connection data for signaling)Conformance with EMC Directive 2014/30/EU
Conductor cross section flexible max. (Connection data, input)16 mm²
Conductor cross section flexible min. (Connection data, input)0.5 mm²
Conductor cross section flexible max. (Connection data, output)4 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Connection in acc. with standard (Connection data for signaling)CSA
Overvoltage category (EN 62477-1) (Connection data for signaling)III
Standard - Safety of transformers (Connection data for signaling)IEC 61558-2-17
Standard - Approval for medical use (Connection data for signaling)IEC 60601-1, 2 x MOOP
Standard – Safety extra-low voltage (Connection data for signaling)IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Limitation of mains harmonic currents (Connection data for signaling)EN 61000-3-2
Information technology equipment - safety (CB scheme) (Connection data for signaling)CB Scheme
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment (Connection data for signaling)EN 50178
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling)EN 50178/VDE 0160 (PELV)

Product Description

Primary Switching Power Supplies, QUINT POWER, Screw Connection, Rail Mounting, SFB Technology (Selective Fuse Breaking), Input:3phase, Output: 48 VDC / 20 A
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top