Key Specifications
GTIN:4046356524902
Orderkey:2320173
Catalog page:Page 260 (C-4-2017)
Packing unit:1 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356524902
Orderkey2320173
Catalog pagePage 260 (C-4-2017)
Packing unit1 pc
(Input data)10 A (Redundancy)
(Output data)
Country of originCN (China)
Custom tariff number85049091
(Ambient conditions)60 A (12 ms, SFB Technology)
Derating (Input data)60 °C ... 70 °C (2.5%/K)
Screw thread (General)M3
Efficiency (Output data)> 98 %
Net weight (Output data)0.4 kg
Stripping length (General)8 mm
Climatic class (Dimensions)3K3 (in acc. with EN 60721)
Connection method (General)Screw connection
Depth (Key Commercial Data)125 mm
Width (Key Commercial Data)32 mm
Height (Key Commercial Data)130 mm
Protection class (Output data)III
Mounting position (Output data)horizontal DIN rail NS 35, EN 60715
(Connection data for signaling)IECEx DEK 11.0015X
Degree of pollution (Dimensions)2
Installation height (Dimensions)2000 m
Connection in series (Input data)No
Degree of protection (Dimensions)IP20
Degree of protection (Output data)IP20
Assembly instructions (Output data)alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Nominal output voltage (Input data)0.1 V (< DC input)
ATEX (Connection data for signaling) II 3 G Ex nA IIC T4 Gc
Weight per Piece (excluding packing)400.000 g
IECEx (Connection data for signaling)Ex nA IIC T4 Gc
Screw thread (Connection data, input)M3
Shock (Connection data for signaling)18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Screw thread (Connection data, output)M3
Voltage (Connection data for signaling)10 V (Test Level 3)
Comments (Connection data for signaling)Criterion B
Input voltage range (Ambient conditions)18 V DC ... 28 V DC (SELV)
MTBF (IEC 61709, SN 29500) (Output data)
Nominal output current (IN) (Input data)20 A (Increasing power)
Power loss nominal load max. (Input data)2 W (IOUT= 20 A)
Stripping length (Connection data, input)7 mm
Conductor cross section AWG max. (General)12
Conductor cross section AWG min. (General)14
Connection method (Connection data, input)Screw connection
Maximum input current (Ambient conditions)2x 15 A (-25°C ... 40°C)
Nominal input current (Ambient conditions)2x 10 A (-25 °C ... 60 °C)
Output overvoltage protection (Input data)≤ 32 V DC
Stripping length (Connection data, output)10 mm
Connection method (Connection data, output)Screw connection
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Conductor cross section solid max. (General)4 mm²
Conductor cross section solid min. (General)0.2 mm²
UL approvals (Connection data for signaling)UL/C-UL listed UL 508
Noise immunity (Connection data for signaling)EN 61000-6-2:2005
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.2 mm²
Frequency range (Connection data for signaling)0.15 MHz ... 80 MHz
Nominal input voltage range (Ambient conditions)24 V DC
Noxious gas test (Connection data for signaling)ISA-S71.04-1985 G3 Harsh Group A
Contact discharge (Connection data for signaling)4 kV (Test Level 2)
Test field strength (Connection data for signaling)3 V/m (Test Level 2)
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 85 °C
Depth with alternative assembly (Key Commercial Data)35 mm
Low Voltage Directive (Connection data for signaling)Conformance with Low Voltage Directive 2006/95/EC
Standards/regulations (Connection data for signaling)EN 61000-6-3
Vibration (operation) (Connection data for signaling)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Width with alternative assembly (Key Commercial Data)122 mm
Height with alternative assembly (Key Commercial Data)130 mm
Ambient temperature (start-up type tested) (Dimensions)-40 °C
Conductor cross section AWG min. (Connection data, input)10
Conductor cross section AWG max. (Connection data, output)12
Conductor cross section AWG min. (Connection data, output)16
Conductor cross section solid max. (Connection data, input)6 mm²
Conductor cross section solid min. (Connection data, input)0.2 mm²
Max. permissible relative humidity (operation) (Dimensions)≤ 100 % (at 25 °C, non-condensing)
Conductor cross section solid max. (Connection data, output)4 mm²
Conductor cross section solid min. (Connection data, output)0.2 mm²
Standard - Electrical safety (Connection data for signaling)EN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibility (Connection data for signaling)Conformance with EMC Directive 2014/30/EU
Conductor cross section flexible max. (Connection data, input)4 mm²
Conductor cross section flexible min. (Connection data, input)0.2 mm²
Conductor cross section flexible max. (Connection data, output)2.5 mm²
Conductor cross section flexible min. (Connection data, output)0.2 mm²
Connection in acc. with standard (Connection data for signaling)CUL
Standard – Safety extra-low voltage (Connection data for signaling)IEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling)EN 50178/VDE 0160 (PELV)

Product Description

QUINT active redundancy module for rail mounting with ACB (Auto Current Balancing) technology and monitoring functions, 24 V DC input, 24 V DC/2 x 10 A or 1 x 20 A output, incl. universal adapter for
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top