Service time: Monday to Friday 9:00-18:00
QUINT-DIODE/48DC/40 - QUINT-DIODE/48DC/40 2866585 PHOENIX CONTACT Redundancy module, with protective coating
In Stock Hot Product

QUINT-DIODE/48DC/40

QUINT-DIODE/48DC/40 2866585 PHOENIX CONTACT Redundancy module, with protective coating

$0.00USD
4478 in stock
Key Specifications
:< 60 V DC (Umax)
LED:no
ATEX: II 3 G Ex nA II T4
Depth:102 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
< 60 V DC (Umax)
LEDno
ATEX II 3 G Ex nA II T4
Depth102 mm
Shock30g, 18 ms in accordance with IEC 60068-2-27
Width62 mm
Height84 mm
Temp codeT4 (70 °C)
Efficiency> 97 %
Product typeRedundancy module
Screw threadM4
UL approvalsUL/C-UL listed UL 508
Assembly notealignable: horizontal 20 mm, vertical 50 mm
Input voltage48 V DC (UN)
Mounting typeDIN rail mounting
Noise emissionEN 55011
Product familyQUINT DIODE
Type of housingAIMg (hood), GD-ZnAICu (cooling unit)
Horizontal pitch3.4 Div.
Housing materialMetal
Protection classII
Stripping length10 mm
Connection methodScrew connection
Mounting positionhorizontal and vertical DIN rail NS 35, EN 60715
Degree of pollution2
Input voltage range10 V DC ... 60 V DC
Connection in seriesno
Degree of protectionIP20
Maximum current Imax2x 19 A (6 mm² at 40°C)
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Tightening torque max1.5 Nm
Vibration (operation)3 Hz ... 15 Hz, amplitude ±2.5 mm; 15 Hz ... 100 Hz, 2.3g according to IEC 60068-2-6
Input voltage range DC10 V DC ... 60 V DC
Nominal output voltage47.3 V DC (Input/output voltage drop of 48 V ... 0.7 V )
Tightening torque, min1.2 Nm
Nominal input current (IN)2x 20 A
Transient surge protectionTransil diode
Voltage drop, input/outputapprox. 0.7 V
Nominal output current (IN)40 A
Reverse polarity protection< yes120 V
Power loss nominal load max.28 W
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Insulation voltage input / PE1 kV
Insulation voltage output / PE1 kV
Voltage type of supply voltageDC
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C derating,  -25 ... 60°C)
Conductor cross section AWG max.6
Conductor cross section AWG min.20
Installation distance right/left5 mm / 5 mm
Installation distance top/bottom50 mm / 50 mm
Conductor cross section, rigid max.16 mm²
Conductor cross section, rigid min.0.5 mm²
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise immunityEN 61000-6-1
Conductor cross section flexible max.10 mm²
Conductor cross section flexible min.0.5 mm²
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Declaration of conformity in acc. with EN 60079-15 II 3 G Ex nA II T4 X
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

Product Description

QUINT-DIODE/48DC/40 Redundancy Module
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top