Service time: Monday to Friday 9:00-18:00
QTC 2,5-QUATTRO - QTC 2,5-QUATTRO 3206446 PHOENIX CONTACT Feed-through terminal block
In Stock Hot Product

QTC 2,5-QUATTRO

QTC 2,5-QUATTRO 3206446 PHOENIX CONTACT Feed-through terminal block

$0.00USD
4236 in stock
Key Specifications
GTIN:4046356898546
Orderkey:3206446
Catalog page:Page 209 (C-1-2017)
Packing unit:50 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356898546
Orderkey3206446
Catalog pagePage 209 (C-1-2017)
Packing unit50 pc
Width (General)6.2 mm
Height (General)37.8 mm
Length (General)102.4 mm
Country of originCN (China)
Custom tariff number85369010
(Key Commercial Data)2.5 mm² / 0.7 kg
Minimum order quantity50 pc
End cover width (General)2.2 mm
Height NS 35/15 (General)46.8 mm
Height NS 35/7,5 (General)39.3 mm
Color (Key Commercial Data)gray
(Standards and Regulations)No hazardous substances above threshold values
Connection method (Dimensions)Quick connection
Setpoint (Key Commercial Data)1 N
ASD level (Key Commercial Data)6.12 (m/s2)2/Hz
Potentials (Key Commercial Data)1
Shock form (Key Commercial Data)Half-sine
Acceleration (Key Commercial Data)30g
Test spectrum (Key Commercial Data)Service life test category 2, bogie-mounted
Shock duration (Key Commercial Data)18 ms
Test frequency (Key Commercial Data)f1= 5 Hz to f2= 250 Hz
Weight per Piece (excluding packing)16.500 g
Material wire insulation (Dimensions)PVC / PE
Open side panel (Key Commercial Data)Yes
Test directions (Key Commercial Data)X-, Y- and Z-axis (pos. and neg.)
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Number of levels (Key Commercial Data)1
Finger protection (Key Commercial Data)guaranteed
Shock test result (Key Commercial Data)Test passed
Bending test turns (Key Commercial Data)135
Nominal current IN (Key Commercial Data)24 A (with a 2.5 mm² conductor cross section)
Nominal voltage UN (Key Commercial Data)800 V
Degree of pollution (Key Commercial Data)3
Insulating material (Key Commercial Data)PA
Rated surge voltage (Key Commercial Data)8 kV
Tensile test result (Key Commercial Data)Test passed
Maximum load current (Key Commercial Data)24 A (at a conductor cross section of 2.5 mm²; it must not be exceeded by the total current.)
Overvoltage category (Key Commercial Data)III
Tight fit on carrier (Key Commercial Data)NS 35
Nominal cross section (Key Commercial Data)2.5 mm²
Number of connections (Key Commercial Data)4
Result of bending test (Key Commercial Data)Test passed
Result of thermal test (Key Commercial Data)Test passed
Test duration per axis (Key Commercial Data)5 h
Conductor cross section AWG max. (Dimensions)14
Conductor cross section AWG min. (Dimensions)20
Connection in acc. with standard (Dimensions)IEC 60947-7-1
Conductor cross section solid max. (Dimensions)2.5 mm²
Conductor cross section solid min. (Dimensions)0.5 mm²
Insulating material group (Key Commercial Data)I
Max. wire diameter incl. insulation (Dimensions)3.8 mm
Requirements, voltage drop (Key Commercial Data)≤ 3.2 mV
Back of the hand protection (Key Commercial Data)guaranteed
Bending test rotation speed (Key Commercial Data)10 rpm
Result of voltage-drop test (Key Commercial Data)Test passed
Surge voltage test setpoint (Key Commercial Data)9.8 kV
Conductor cross section flexible max. (Dimensions)2.5 mm²
Conductor cross section flexible min. (Dimensions)0.5 mm²
Connection in acc. with standard (Connection data)IEC 60947-7-1
Result of surge voltage test (Key Commercial Data)Test passed
NF F16-101, NF F10-102 Class F (Key Commercial Data)2
NF F16-101, NF F10-102 Class I (Key Commercial Data)2
Number of shocks per direction (Key Commercial Data)3
Result of tight fit on support (Key Commercial Data)Test passed
Test specification, shock test (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Ambient temperature (actuation) (Key Commercial Data)-10 °C ... 90 °C
Result of temperature-rise test (Key Commercial Data)Test passed
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data)>32 %
Max. AWG conductor cross section, flexible (Dimensions)14
Min. AWG conductor cross section, flexible (Dimensions)20
Flammability rating according to UL 94 (Connection data)V0
Shock protection test specification (Key Commercial Data)DIN EN 50274 (VDE 0660-514):2002-11
Flame test method (DIN EN 60695-11-10) (Key Commercial Data)V0
Flammability rating according to UL 94 (Key Commercial Data)V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data)passed
Oscillation, broadband noise test result (Key Commercial Data)Test passed
Power frequency withstand voltage setpoint (Key Commercial Data)2 kV
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data)passed
Bending test conductor cross section/weight (Key Commercial Data)0.5 mm² / 0.3 kg
Static insulating material application in cold (Key Commercial Data)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data)Test passed
Maximum power dissipation for nominal condition (Key Commercial Data)0.77 W
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data)28 MJ/kg
Result of power-frequency withstand voltage test (Key Commercial Data)Test passed
Test specification, oscillation, broadband noise (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data)passed
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data)130 °C
Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data)30 s
Structure of individual litz in acc. with VDE 0295 / smallest wire diameter (Dimensions)VDE 0295 Cl.1-5
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data)130 °C
Result of the test for mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data)Test passed

Product Description

Feed-through terminal, nominal voltage: 800 V, nominal current: 24 A, number of connections: 4, connection type: Quick connection, 1st floor, Dimensioning cross-section: 2.5 mm², cross-section: 0.5 mm
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top