| Parameter | Value |
|---|---|
| GTIN | 4046356932318 |
| (Cabel) | IP69K |
| Orderkey | 1411432 |
| Catalog page | Page 480 (C-2-2017) |
| Packing unit | 1 pc |
| Country of origin | PL (Poland) |
| Custom tariff number | 85366990 |
| (Key Commercial Data) | IDC connection |
| Position marking (General) | 1, 2, 3, N, PE |
| Type (Key Commercial Data) | QPD 5x2,5 |
| Color (Key Commercial Data) | black |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Degree of protection (Cabel) | IP66 |
| Connection (Key Commercial Data) | For 2.5 mm² cables with ferrule, only CRIMPFOX 10S pliers (1212045) with square crimp can be used.CRIMPFOX 6H hexagonal crimping pliers (1212046) cannot be used, because the diameter on the diagonal is too large. |
| External cable diameter (General) | 6 mm ... 11 mm |
| Locking type (Key Commercial Data) | Screw locking |
| Rated current (Ambient conditions) | 20 A |
| Wire insulation material (General) | PVC/PE/Rubber/TPE |
| Weight per Piece (excluding packing) | 62.000 g |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Ambient temperature (operation) (Cabel) | -40 °C ... 100 °C |
| Connection method (Key Commercial Data) | QUICKON connection |
| Nominal current IN (Ambient conditions) | 20 A |
| Number of positions (Key Commercial Data) | 5 |
| Rated voltage (II/2) (Ambient conditions) | 1000 V |
| Rated voltage (III/2) (Ambient conditions) | 1000 V |
| Rated voltage (III/3) (Ambient conditions) | 690 V |
| Number of connections (Key Commercial Data) | 10 |
| Temperature when conductor connected (Cabel) | -5 °C ... 50 °C |
| Wire diameter including insulation (General) | 2 mm ... 3.8 mm |
| Wrench size, union nut (Key Commercial Data) | 27 mm |
| Contact material (Mechanical characteristics) | Cu |
| Note number of positions (Key Commercial Data) | 4+PE |
| Wrench size, counter nut (Key Commercial Data) | 30 mm |
| Ambient temperature (storage/transport) (Cabel) | -40 °C ... 80 °C |
| Rated surge voltage (II/2) (Ambient conditions) | 8 kV |
| Degree of pollution (Mechanical characteristics) | 3 |
| Insulating material (Mechanical characteristics) | PA |
| Rated surge voltage (III/2) (Ambient conditions) | 8 kV |
| Rated surge voltage (III/3) (Ambient conditions) | 6 kV |
| Overvoltage category (Mechanical characteristics) | III |
| Tightening torque, union nut (Key Commercial Data) | 10 Nm |
| QUICKON connectability (Electrical characteristics) | max. 10 |
| Tightening torque, counter nut (Key Commercial Data) | 5 Nm |
| Category of shock impact (Electrical characteristics) | IK07 |
| Contact carrier material (Mechanical characteristics) | PA |
| Contact surface material (Mechanical characteristics) | silver-plated |
| Conductor cross section AWG max. (Key Commercial Data) | 14 |
| Conductor cross section AWG min. (Key Commercial Data) | 16 |
| Flammability rating according to UL 94 (Material data) | V0 |
| Conductor cross section solid max. (Key Commercial Data) | 2.5 mm² |
| Conductor cross section solid min. (Key Commercial Data) | 1 mm² |
| Insertion/withdrawal cycles (Electrical characteristics) | QUICKON connections max. 10 |
| Conductor cross section flexible max. (Key Commercial Data) | 2.5 mm² |
| Conductor cross section flexible min. (Key Commercial Data) | 1 mm² |
| Flammability rating according to UL 94 (Mechanical characteristics) | V0 |
| Structure of individual litz in acc. with VDE 0295 / smallest wire diameter (General) | VDE 0295 class 1 to 6/min. 0.15 mm |