| Parameter | Value |
|---|---|
| GTIN | 4055626315720 |
| Orderkey | 1422813 |
| Packing unit | 1 |
| Custom tariff number | 85472000 |
| Type (Key Commercial Data) | QPD 4x2,5 |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Locking type (Key Commercial Data) | Screw locking |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Standards and Regulations) | |
| Nominal current IN (Ambient conditions) | 20 A |
| Ambient temperature (operation) (General) | -40 °C ... 100 °C |
| Number of positions (Key Commercial Data) | 4 |
| Note number of positions (Key Commercial Data) | 3+PE |
| Temperature when conductor connected (General) | -5 °C ... 50 °C |
| Degree of pollution (Mechanical characteristics) | 3 |
| Insulating material (Mechanical characteristics) | PA |
| Ambient temperature (storage/transport) (General) | -40 °C ... 80 °C |
| Overvoltage category (Mechanical characteristics) | III |
| Category of shock impact (Electrical characteristics) | IK07 |
| Contact carrier material (Mechanical characteristics) | PA |
| Flammability rating according to UL 94 (Material data) | V0 |
| Flammability rating according to UL 94 (Mechanical characteristics) | V0 |
Technical specifications and performance data