| Parameter | Value |
|---|---|
| 690 V DC | |
| Type | QPD 5x2,5 |
| Color | black (RAL 9005) |
| Width | 34.6 mm |
| Height | 39.1 mm |
| Length | 5.18 mm |
| Diameter | 34.6 mm |
| Shielded | no |
| Cable type | PVC gray |
| Cable length | 5 m |
| Cable weight | 242 kg/km |
| Product type | Assembled installation cable |
| Overall twist | 5 cores, twisted |
| Rated current | 20 A |
| Product family | QPD |
| Impact strength | IK07 |
| AWG power supply | 14 |
| Article revision | 03 |
| Flame resistance | according to IEC 60332-1-2 |
| Material Housing | PA |
| Position marking | 1, 2, 3, N, PE |
| Conductor material | Bare Cu litz wires |
| Connection profile | 4+PE |
| Contact resistance | < 4 mΩ |
| Nominal current IN | 20 A |
| Nominal voltage UN | 690 V AC |
| Single wire, color | blue, brown, black, gray, green/yellow |
| Degree of pollution | 3 |
| Dimensional drawing | |
| Number of positions | 5 |
| Test voltage, cable | 4000 V |
| Degree of protection | IP66 |
| Overvoltage category | III |
| rated voltage (II/2) | 1000 V |
| Number of connections | 5 |
| Rated voltage (III/3) | 690 V |
| Wrench size Union nut | 27 mm |
| rated voltage (III/2) | 1000 V |
| External sheath, color | gray RAL 7001 |
| Nominal voltage, cable | 750 V |
| Outer sheath, material | PVC |
| Conductor cross section | 5x 2.5 mm² |
| External cable diameter | 11.80 mm |
| Material Contact surface | silver-plated |
| Material wire insulation | PVC/PE/TPE/rubber |
| Cable type (abbreviation) | PVC |
| Rated surge voltage (II/2) | 8 kV |
| Cable insulation resistance | > 0.2 MΩ*km |
| Insertion/withdrawal cycles | max. 50 |
| Rated surge voltage (III/2) | 8 kV |
| Rated surge voltage (III/3) | 6 kV |
| Tightening torque Union nut | 10 Nm |
| Connection cross section AWG | 16 ... 14 |
| Conductor cross section solid | 1 mm² ... 2.5 mm² |
| Ambient temperature (operation) | -5 °C ... 70 °C (Cable, flexible installation) |
| Conductor cross section flexibel | 1 mm² ... 2.5 mm² |
| Number of connections per position | 1 |
| Conductor structure, voltage supply | 50x 0.25 mm |
| Connection method On the field side | IDC connection |
| Temperature when conductor connected | -5 °C ... 50 °C |
| Flammability rating according to UL 94 | V0 |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Minimum bending radius, fixed installation | 4 x D |
| Minimum bending radius, flexible installation | 15 x D |
| Frequency of connections between conductors of the same cross section | max. 10 |
Technical specifications and performance data
Installation and operation guide