| Parameter | Value |
|---|---|
| Color | gray |
| Open side panel | No |
| Width (General) | 12.1 mm |
| Number of levels | 1 |
| UNSPSC 11 (ETIM) | 39121410 |
| ETIM 3.0 (eCl@ss) | EC001283 |
| ETIM 4.0 (eCl@ss) | EC001283 |
| ETIM 5.0 (eCl@ss) | EC001283 |
| (Connection data) | IEC 60947-7-1 |
| Nominal current IN | 76 A |
| Nominal voltage UN | 1000 V |
| UNSPSC 13.2 (ETIM) | 39121410 |
| UNSPSC 6.01 (ETIM) | 30211811 |
| Degree of pollution | 3 |
| Insulating material | PA |
| Number of positions | 1 |
| Rated surge voltage | 8 kV |
| UNSPSC 12.01 (ETIM) | 39121410 |
| Maximum load current | 76 A |
| Overvoltage category | III |
| UNSPSC 7.0901 (ETIM) | 39121410 |
| Nominal cross section | 16 mm² |
| Number of connections | 2 |
| Insulating material group | I |
| Plate thickness (General) | 1 mm ... 6 mm |
| Connection side (Dimensions) | Inside |
| Stripping length (Dimensions) | 18 mm |
| Ambient temperature (assembly) | -5 °C ... 100 °C |
| Connection method (Dimensions) | Cable lug connection |
| Ambient temperature (actuation) | -5 °C ... 100 °C |
| Ambient temperature (operation) | -40 °C (depending on the current carrying capacity curve) |
| Connection in acc. with standard | IEC 60947-7-1 |
| Flammability rating according to UL 94 | V0 |
| eCl@ss 4.0 (Standards and Regulations) | 27141131 |
| eCl@ss 4.1 (Standards and Regulations) | 27141131 |
| eCl@ss 5.0 (Standards and Regulations) | 27141134 |
| eCl@ss 5.1 (Standards and Regulations) | 27141134 |
| eCl@ss 6.0 (Standards and Regulations) | 27141134 |
| eCl@ss 7.0 (Standards and Regulations) | 27141134 |
| eCl@ss 8.0 (Standards and Regulations) | 27141134 |
| eCl@ss 9.0 (Standards and Regulations) | 27141134 |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Conductor cross section AWG max. (Dimensions) | 4 |
| Conductor cross section AWG min. (Dimensions) | 14 |
| Conductor cross section solid max. (Dimensions) | 16 mm² |
| Conductor cross section solid min. (Dimensions) | 1.5 mm² |
| Conductor cross section flexible max. (Dimensions) | 16 mm² |
| Conductor cross section flexible min. (Dimensions) | 1.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 16 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 1.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 16 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 1.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) | 4 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions) | 1.5 mm² |
Technical specifications and performance data
Installation and operation guide