PV-SET 2ST/1000DC/2MPP-SPD-SC - PV-SET 2ST/1000DC/2MPP-SPD-SC 2801317 PHOENIX CONTACT Surge protection device set
In Stock Hot Product

PV-SET 2ST/1000DC/2MPP-SPD-SC

PV-SET 2ST/1000DC/2MPP-SPD-SC 2801317 PHOENIX CONTACT Surge protection device set

$0.00USD
3733 in stock
Key Specifications
:PV T2
Note:2011
Type:Installation housing
Depth:122 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
PV T2
Note2011
TypeInstallation housing
Depth122 mm
Width200 mm
Height200 mm
Screw threadM2
Mounting typeSurface/Wall mounting
Set comprises1774674 PV-CF-S 2,5-6 (+)
Cover materialPolycarbonate, transparent
Impact strengthIK08
Horizontal pitch9 Div.
Housing materialPolycarbonate, glass-fiber-reinforced
Pollution degree2
Protection classII
Response time tA≤ 25 ns
Stripping length7 mm
Connection methodMC 1,5/3
Tightening torque2 lbf-in. ... 4 lbf-in.
Ambient conditionsA, B
Connector materialPA
Nominal current IN25 A DC (per MPP)
Switching functionChangeover contact, 1-pos.
Direction of action(L+)-PE & (L-)-PE & (L+)-(L-)
Degree of protectionIP65
Overvoltage categoryIII
Residual current IPE≤ 25 µA
Rated load current IL80 A DC
Standards/regulationsEN 50539-11
Tightening torque, min0.25 Nm
IEC test classificationPV T1
Standards/specificationsIEC 61439-2
Conductor cross section AWG30 ... 14 (UL)
Max. operating current Imax1.5 A AC (250 V AC)
Open circuit voltage UOCSTC830 V DC (Solar generator)
Response time tA(L+) - (L-)≤ 25 ns
Response time tA(L+/L-) - PE≤ 25 ns
Short-circuit current ISCSTC25 A DC (per MPP)
Standby power consumption PC≤ 25 mVA
Surge protection fault messageoptical
Ambient temperature (operation)-30 °C ... 55 °C
Recommended backup fuse maximumnot required
Maximum operating voltage UmaxDC30 V DC
Maximum operating voltage Umax.AC250 V AC
Conductor cross section, rigid max.1.5 mm²
Conductor cross section, rigid min.0.14 mm²
Max. backup fuse with branch wiringnot required
Rated surge voltage resistance Uimp6 kV
Conductor cross section flexible max.1.5 mm²
Conductor cross section flexible min.0.14 mm²
Flammability rating according to UL 94V2 (Gehäuse / Deckel)
Nominal discharge current In(8/20) µs15 kA
Voltage protection level Up(L+) - (L-)≤ 3.5 kV
Voltage protection level Up(L+/L-) - PE≤ 3.5 kV
Maximum discharge current Imax(8/20) µs40 kA
Total discharge current Itotal(8/20) µs40 kA
Total discharge current Itotal(10/350) µs5 kA
Impulse discharge current (10/350) µs, peak value limp5 kA

Product Description

Lightning and surge arrester in IP65 housing for protecting the DC side of an inverter with two MPP trackers up to 1000 V DC, connection via SUNCLIX plug/socket, plug-in varistors with thermal disconn
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide