| Parameter | Value |
|---|---|
| • WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product. | |
| Width | 5.4 mm |
| Height | 5.4 mm |
| Length | 33.1 mm |
| Safety note | • WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible. |
| Product type | Crimp contact |
| Product family | SUNCLIX |
| Contact surface | Silver Ag |
| Insertion force | 45 N ±10 N |
| Article revision | 05 |
| Contact material | Cu |
| Connection method | Crimp |
| Contact resistance | 0.45 mΩ |
| Notes on operation | Crimping recommendation: Crimp the conductor with the crimp contact in accordance with IEC 60352 |
| Degree of pollution | 2 |
| Dimensional drawing | |
| Note on application | When using the CRIMPFOX-P SR 6 manual crimping tool, item no. 1212755, please note the use of the standard locator (no marking). |
| Maximum load current | 35 A (for 4 mm²) |
| Rated voltage (II/2) | 1000 V |
| Rated voltage (III/2) | 1500 V |
| Contact connection type | Socket |
| Contact surface material | Ag |
| Rated current (2.5 mm²) | 27 A |
| Rated current (4.0 mm²) | 35 A |
| Insulating material group | I / CTI 600 |
| Rated surge voltage (II/2) | 12 kV |
| Cross section range, metric | 2.5 mm² ... 4 mm² |
| Rated surge voltage (III/2) | 12 kV |
| Rated surge voltage (III/3) | 16 kV |
| Ambient temperature (assembly) | -25 °C ... 50 °C |
| Ambient temperature (operation) | -40 °C ... 85 °C |
| Conductor cross section flexible | 2.5 mm² ... 4 mm² |
| Degree of protection (not plugged in) | IP20 |
| Degree of protection (when plugged in) | IP66 / IP68 (2 m / 24 h) |
| Flammability rating according to UL 94 | V0 |
| Stripping length of the individual wire | 8 mm -1 mm |
Technical specifications and performance data