Service time: Monday to Friday 9:00-18:00
PTWE 6-2/E7 - PTWE 6-2/E7 3069438 PHOENIX CONTACT Test terminal strip
In Stock Hot Product

PTWE 6-2/E7

PTWE 6-2/E7 3069438 PHOENIX CONTACT Test terminal strip

$0.00USD
4525 in stock
Key Specifications
GTIN:4046356943505
Note:Made to Order (non-returnable)
Orderkey:3069438
Catalog page:Page 608 (C-1-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356943505
NoteMade to Order (non-returnable)
Orderkey3069438
Catalog pagePage 608 (C-1-2017)
Packing unit1 pc
Pitch (General)8.2 mm
Width (General)90.2 mm
Height (General)56.5 mm
Length (General)100 mm
Country of originPL (Poland)
Custom tariff number85369010
(Key Commercial Data)10 mm² / 2 kg
Plate thickness (General)1 mm ... 4 mm
Color (Key Commercial Data)gray
(Standards and Regulations)No hazardous substances above threshold values
Stripping length (Dimensions)12 mm
Connection method (Dimensions)Push-in connection
Setpoint (Key Commercial Data)5 N
ASD level (Key Commercial Data)6.12 (m/s2)2/Hz
Mounting type (Connection data)Wall mounting
Potentials (Key Commercial Data)7
Shock form (Key Commercial Data)Half-sine
Current Ith (Key Commercial Data)24 A
Plate thickness (Connection data)1 mm ... 4 mm
Acceleration (Key Commercial Data)30g
Test spectrum (Key Commercial Data)Service life test category 2, bogie-mounted
Shock duration (Key Commercial Data)18 ms
Test frequency (Key Commercial Data)f1= 5 Hz to f2= 250 Hz
Weight per Piece (excluding packing)99.990 g
Open side panel (Key Commercial Data)No
Test directions (Key Commercial Data)X-, Y- and Z-axis (pos. and neg.)
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Internal cylindrical gage (Dimensions)A5
Number of levels (Key Commercial Data)1
Finger protection (Key Commercial Data)guaranteed
Shock test result (Key Commercial Data)Test passed
Bending test turns (Key Commercial Data)135
Nominal voltage UN (Key Commercial Data)400 V AC/DC
Short-time current (Key Commercial Data)0.15 kA
Test surge voltage (Key Commercial Data)5 kV
Insulating material (Key Commercial Data)PA
Number of positions (Key Commercial Data)7
Rated surge voltage (Key Commercial Data)4 kV
Tensile test result (Key Commercial Data)Test passed
Maximum load current (Key Commercial Data)30 A (with 6 mm² conductor cross section)
Overvoltage category (Key Commercial Data)III
Result of aging test (Key Commercial Data)Test passed
Connection in acc. with standard (Mounting)IEC 60947-7-1
Nominal cross section (Key Commercial Data)6 mm²
Number of connections (Key Commercial Data)14
Result of bending test (Key Commercial Data)Test passed
Result of thermal test (Key Commercial Data)Test passed
Test duration per axis (Key Commercial Data)5 h
Conductor cross section AWG max. (Dimensions)8
Conductor cross section AWG min. (Dimensions)20
Connection in acc. with standard (Dimensions)IEC 60947-7-1
Terminal block mounting (Key Commercial Data)0.8 Nm ... 1 Nm
Tractive force setpoint (Key Commercial Data)90 N
Conductor cross section solid max. (Dimensions)10 mm²
Conductor cross section solid min. (Dimensions)0.5 mm²
Insulating material group (Key Commercial Data)I
Requirements, voltage drop (Key Commercial Data)≤ 4.8 mV
Back of the hand protection (Key Commercial Data)guaranteed
Bending test rotation speed (Key Commercial Data)10 rpm
Flammability rating according to UL 94 (Mounting)V0
Result of voltage-drop test (Key Commercial Data)Test passed
Surge voltage test setpoint (Key Commercial Data)4.8 kV
Conductor cross section flexible max. (Dimensions)6 mm²
Conductor cross section flexible min. (Dimensions)0.5 mm²
Result of surge voltage test (Key Commercial Data)Test passed
NF F16-101, NF F10-102 Class F (Key Commercial Data)2
NF F16-101, NF F10-102 Class I (Key Commercial Data)2
Number of shocks per direction (Key Commercial Data)3
Result of tight fit on support (Key Commercial Data)Test passed
Short circuit stability result (Key Commercial Data)Test passed
Test specification, shock test (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Note regarding shock protection (Key Commercial Data)When test disconnect plug is plugged in.
Result of temperature-rise test (Key Commercial Data)Test passed
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data)>32 %
Max. AWG conductor cross section, flexible (Dimensions)10
Min. AWG conductor cross section, flexible (Dimensions)20
Shock protection test specification (Key Commercial Data)DIN EN 50274 (VDE 0660-514):2002-11
Conductor cross section tensile test (Key Commercial Data)10 mm²
Flame test method (DIN EN 60695-11-10) (Key Commercial Data)V0
Flammability rating according to UL 94 (Key Commercial Data)V0
Insertion/withdrawal cycles mechanical (Key Commercial Data)100
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data)passed
Oscillation, broadband noise test result (Key Commercial Data)Test passed
Max. tightening torque of the mounting screw: (Connection data)1 Nm
Min. tightening torque of the mounting screw: (Connection data)0.8 Nm
Power frequency withstand voltage setpoint (Key Commercial Data)1.89 kV
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data)passed
Bending test conductor cross section/weight (Key Commercial Data)0.5 mm² / 0.3 kg
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Mounting)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Mounting)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Mounting)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Mounting)HL 1 - HL 3
Conductor cross section short circuit testing (Key Commercial Data)4 mm²
Static insulating material application in cold (Key Commercial Data)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data)Test passed
Maximum power dissipation for nominal condition (Key Commercial Data)1.31 W
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data)27,5 MJ/kg
Result of power-frequency withstand voltage test (Key Commercial Data)Test passed
Test specification, oscillation, broadband noise (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data)passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions)6 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions)0.5 mm²
Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data)130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions)6 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions)0.5 mm²
Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data)30 s
Ageing test for screwless modular terminal block temperature cycles (Key Commercial Data)192
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data)125 °C
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions)1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions)0.5 mm²
Result of the test for mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data)Test passed

Product Description

Test pin strip, with VDE type E7 coding, nominal voltage: 400 V, number of connections: 14, number of poles: 7, connection type: Push-in connection, 1st floor, Dimensioning section: 6 mm², section: 0.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top