

| Parameter | Value |
|---|---|
| GTIN | 4055626797076 |
| Orderkey | 1078966 |
| (Drawings) | 4 mm² / 0.9 kg |
| Catalog page | Page 88 (C-1-2019) |
| Packing unit | 1 pc |
| Width (General) | 5.2 mm |
| Color (Drawings) | gray |
| Height (General) | 45.7 mm |
| Length (General) | 60 mm |
| UNSPSC 11 (ETIM) | 39121410 |
| Country of origin | CN (China) |
| ETIM 2.0 (eCl@ss) | EC000897 |
| ETIM 3.0 (eCl@ss) | EC000897 |
| ETIM 4.0 (eCl@ss) | EC000897 |
| ETIM 5.0 (eCl@ss) | EC000897 |
| ETIM 6.0 (eCl@ss) | EC000897 |
| ETIM 7.0 (eCl@ss) | EC000897 |
| UNSPSC 13.2 (ETIM) | 39121410 |
| UNSPSC 18.0 (ETIM) | 39121410 |
| UNSPSC 19.0 (ETIM) | 39121410 |
| UNSPSC 20.0 (ETIM) | 39121410 |
| UNSPSC 21.0 (ETIM) | 39121410 |
| UNSPSC 6.01 (ETIM) | 30211811 |
| Setpoint (Drawings) | 1 N |
| UNSPSC 12.01 (ETIM) | 39121410 |
| ASD level (Drawings) | 6.12 (m/s2)2/Hz |
| Custom tariff number | 85369010 |
| UNSPSC 7.0901 (ETIM) | 39121410 |
| Potentials (Drawings) | 1 |
| Shock form (Drawings) | Half-sine |
| Minimum order quantity | 50 pc |
| Acceleration (Drawings) | 30g |
| Connection (Dimensions) | 1 level |
| Test spectrum (Drawings) | Service life test category 2, bogie-mounted |
| End cover width (General) | 2.2 mm |
| Height NS 35/15 (General) | 54.4 mm |
| Shock duration (Drawings) | 18 ms |
| Test frequency (Drawings) | f1= 5 Hz to f2= 250 Hz |
| Height NS 35/7,5 (General) | 46.9 mm |
| Open side panel (Drawings) | Yes |
| Test directions (Drawings) | X-, Y- and Z-axis (pos. and neg.) |
| Number of levels (Drawings) | 1 |
| Finger protection (Drawings) | guaranteed |
| Shock test result (Drawings) | Test passed |
| eCl@ss 4.0 (Classifications) | 27141121 |
| eCl@ss 4.1 (Classifications) | 27141121 |
| eCl@ss 5.0 (Classifications) | 27141120 |
| eCl@ss 5.1 (Classifications) | 27141100 |
| eCl@ss 6.0 (Classifications) | 27141100 |
| eCl@ss 7.0 (Classifications) | 27141120 |
| eCl@ss 8.0 (Classifications) | 27141120 |
| eCl@ss 9.0 (Classifications) | 27141120 |
| Bending test turns (Drawings) | 135 |
| Nominal current IN (Drawings) | 24 A (with 2.5 mm² conductor connection cross section) |
| Nominal voltage UN (Drawings) | 800 V |
| Short-time current (Drawings) | 0.48 kA |
| Stripping length (Dimensions) | 8 mm ... 10 mm |
| Area of application (Drawings) | Railway industry |
| Connection method (Dimensions) | Push-in connection |
| Degree of pollution (Drawings) | 3 |
| Insulating material (Drawings) | PA |
| Rated surge voltage (Drawings) | 8 kV |
| Tensile test result (Drawings) | Test passed |
| Maximum load current (Drawings) | 28 A (with 4 mm² conductor cross section) |
| Overvoltage category (Drawings) | III |
| Result of aging test (Drawings) | Test passed |
| Tight fit on carrier (Drawings) | NS 35 |
| Nominal cross section (Drawings) | 2.5 mm² |
| Number of connections (Drawings) | 3 |
| Result of bending test (Drawings) | Test passed |
| Result of thermal test (Drawings) | Test passed |
| Test duration per axis (Drawings) | 5 h |
| Tractive force setpoint (Drawings) | 60 N |
| Insulating material group (Drawings) | I |
| Weight per Piece (excluding packing) | 8.000 g |
| Requirements, voltage drop (Drawings) | ≤ 3.2 mV |
| Back of the hand protection (Drawings) | guaranteed |
| Bending test rotation speed (Drawings) | 10 rpm |
| Internal cylindrical gage (Dimensions) | A3 |
| Result of voltage-drop test (Drawings) | Test passed |
| Surge voltage test setpoint (Drawings) | 9.8 kV |
| Result of surge voltage test (Drawings) | Test passed |
| NF F16-101, NF F10-102 Class F (Drawings) | 2 |
| NF F16-101, NF F10-102 Class I (Drawings) | 2 |
| Number of shocks per direction (Drawings) | 3 |
| Result of tight fit on support (Drawings) | Test passed |
| Short circuit stability result (Drawings) | Test passed |
| Test specification, shock test (Drawings) | DIN EN 50155 (VDE 0115-200):2018-05 |
| Result of temperature-rise test (Drawings) | Test passed |
| Oxygen index (DIN EN ISO 4589-2) (Drawings) | >32 % |
| Conductor cross section AWG max. (Dimensions) | 12 |
| Conductor cross section AWG min. (Dimensions) | 26 |
| Connection in acc. with standard (Dimensions) | IEC 60947-7-1 |
| Shock protection test specification (Drawings) | DIN EN 50274 (VDE 0660-514):2002-11 |
| Conductor cross section solid max. (Dimensions) | 4 mm² |
| Conductor cross section solid min. (Dimensions) | 0.14 mm² |
| Conductor cross section tensile test (Drawings) | 4 mm² |
| Flame test method (DIN EN 60695-11-10) (Drawings) | V0 |
| Flammability rating according to UL 94 (Drawings) | V0 |
| Smoke gas toxicity NFPA 130 (SMP 800C) (Drawings) | passed |
| Conductor cross section flexible max. (Dimensions) | 2.5 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.14 mm² |
| Connection in acc. with standard (Connection data) | IEC 60947-7-1 |
| Oscillation, broadband noise test result (Drawings) | Test passed |
| Power frequency withstand voltage setpoint (Drawings) | 2 kV |
| Surface flammability NFPA 130 (ASTM E 162) (Drawings) | passed |
| Bending test conductor cross section/weight (Drawings) | 0.14 mm² / 0.2 kg |
| Max. AWG conductor cross section, flexible (Dimensions) | 14 |
| Min. AWG conductor cross section, flexible (Dimensions) | 26 |
| Conductor cross section short circuit testing (Drawings) | 4 mm² |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Static insulating material application in cold (Drawings) | -60 °C |
| Behavior in fire for rail vehicles (DIN 5510-2) (Drawings) | Test passed |
| Calorimetric heat release NFPA 130 (ASTM E 1354) (Drawings) | 27,5 MJ/kg |
| Result of power-frequency withstand voltage test (Drawings) | Test passed |
| Test specification, oscillation, broadband noise (Drawings) | DIN EN 50155 (VDE 0115-200):2018-05 |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 (Drawings) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 (Drawings) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 (Drawings) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 (Drawings) | HL 1 - HL 3 |
| Specific optical density of smoke NFPA 130 (ASTM E 662) (Drawings) | passed |
| Relative insulation material temperature index (Elec., UL 746 B) (Drawings) | 130 °C |
| Proof of thermal characteristics (needle flame) effective duration (Drawings) | 30 s |
| Ageing test for screwless modular terminal block temperature cycles (Drawings) | 192 |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Drawings) | 125 °C |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 2.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 0.14 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 2.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 0.14 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions) | 1 mm² |
| Result of the test for mechanical stability of terminal points (5 x conductor connection) (Drawings) | Test passed |
Technical specifications and performance data
Installation and operation guide