| Parameter | Value |
|---|---|
| IEC 60947-7-1 | |
| Color | blue (RAL 5015) |
| Width | 19.4 mm |
| Height | 79.9 mm |
| Potentials | 1 |
| Product type | Potential distributor |
| Screw thread | M6 |
| Mounting type | NS 35/7,5 |
| Number of rows | 1 |
| Nominal current | 57 A |
| Nominal voltage | 1000 V |
| Open side panel | No |
| Article revision | 01 |
| Stripping length | 18 mm ... 20 mm |
| Cross section AWG | 20 ... 6 (converted acc. to IEC) |
| Tightening torque | 3.2 ... 3.7 Nm |
| Depth on NS 35/15 | 57.8 mm |
| Notes on operation | In the end application, the applicable safety regulations for overload and short-circuit protection on the connected conductors must be considered. |
| Degree of pollution | 2 |
| Depth on NS 35/7,5 | 50.3 mm |
| Insulating material | PA |
| Rated surge voltage | 8 kV |
| Maximum load current | 57 A |
| Overvoltage category | III |
| Nominal cross section | 10 mm² |
| Number of connections | 5 |
| Insulating material group | I |
| Internal cylindrical gage | B9 |
| Conductor cross section rigid | 0.5 mm² ... 16 mm² |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Number of connections per level | 5 |
| Conductor cross section flexible | 0.5 mm² ... 10 mm² |
| Connection in acc. with standard | IEC 60947-7-1 |
| Permissible humidity (operation) | 20 % ... 90 % |
| Flammability rating according to UL 94 | V0 |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Conductor cross section, flexible [AWG] | 20 ... 8 (converted acc. to IEC) |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| 2 conductors with same cross section, solid | 1.5 mm² ... 16 mm² |
| 2 conductors with same cross section, flexible | 1.5 mm² ... 10 mm² |
| Maximum power dissipation for nominal condition | 2.43 W |
| 2 conductors with the same cross-section AWG rigid | 16 ... 6 (converted acc. to IEC) |
| 2 conductors with the same cross-section AWG flexible | 16 ... 8 (converted acc. to IEC) |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.5 mm² ... 10 mm² |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.5 mm² ... 10 mm² |
| 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 1.5 mm² ... 4 mm² |