| Parameter | Value |
|---|---|
| GTIN | 4055626047614 |
| Note | Made to Order (non-returnable) |
| Orderkey | 3211890 |
| Catalog page | Page 95 (C-1-2017) |
| Packing unit | 50 pc |
| Width (General) | 6.2 mm |
| Length (General) | 102.9 mm |
| Country of origin | CN (China) |
| (Connection data) | IEC 60947-7-3 |
| Custom tariff number | 85369010 |
| (Key Commercial Data) | max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit) |
| Minimum order quantity | 50 pc |
| Height NS 35/15 (General) | 83 mm |
| Fuse (Key Commercial Data) | G / 5 x 20 |
| Height NS 35/7,5 (General) | 75.5 mm |
| Color (Key Commercial Data) | black |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Stripping length (Dimensions) | 10 mm ... 12 mm |
| Connection method (Dimensions) | Push-in connection |
| ASD level (Key Commercial Data) | 0.964 (m/s2)2/Hz |
| Fuse type (Key Commercial Data) | Glass / ceramics / ... |
| Shock form (Key Commercial Data) | Half-sine |
| Acceleration (Key Commercial Data) | 5 g |
| Test spectrum (Key Commercial Data) | Service life test category 1, class B, body mounted |
| Shock duration (Key Commercial Data) | 30 ms |
| Test frequency (Key Commercial Data) | f1= 5 Hz to f2= 150 Hz |
| Weight per Piece (excluding packing) | 24.290 g |
| Open side panel (Key Commercial Data) | No |
| Test directions (Key Commercial Data) | X-, Y- and Z-axis (pos. and neg.) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Internal cylindrical gage (Dimensions) | A4 |
| Number of levels (Key Commercial Data) | 2 |
| Finger protection (Key Commercial Data) | guaranteed |
| LED current range (Key Commercial Data) | 0.4 mA ... 0.86 mA |
| LED voltage range (Key Commercial Data) | 30 V AC/DC ... 60 V AC/DC |
| Shock test result (Key Commercial Data) | Test passed |
| Nominal current IN (Key Commercial Data) | 28 A |
| Nominal voltage UN (Key Commercial Data) | 500 V |
| Degree of pollution (Key Commercial Data) | 3 |
| Insulating material (Key Commercial Data) | PA |
| Rated surge voltage (Key Commercial Data) | 6 kV |
| Maximum load current (Key Commercial Data) | 32 A |
| Overvoltage category (Key Commercial Data) | III |
| Nominal cross section (Key Commercial Data) | 4 mm² |
| Number of connections (Key Commercial Data) | 4 |
| Test duration per axis (Key Commercial Data) | 5 h |
| Conductor cross section AWG max. (Dimensions) | 10 |
| Conductor cross section AWG min. (Dimensions) | 24 |
| Rated operating voltage (Key Commercial Data) | 250 V |
| Conductor cross section solid max. (Dimensions) | 6 mm² |
| Conductor cross section solid min. (Dimensions) | 0.2 mm² |
| Insulating material group (Key Commercial Data) | I |
| Maximum power dissipation (Key Commercial Data) | max. 1.6 W (With single arrangement of the fuse terminal block in the event of overload) |
| Back of the hand protection (Key Commercial Data) | guaranteed |
| Conductor cross section flexible max. (Dimensions) | 4 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.2 mm² |
| Connection in acc. with standard (Connection data) | IEC 60947-7-1 |
| NF F16-101, NF F10-102 Class F (Key Commercial Data) | 2 |
| NF F16-101, NF F10-102 Class I (Key Commercial Data) | 2 |
| Number of shocks per direction (Key Commercial Data) | 3 |
| Test specification, shock test (Key Commercial Data) | DIN EN 50155 (VDE 0115-200):2008-03 |
| Nominal current IN(upper level) (Key Commercial Data) | 6.3 A |
| Connection in acc. with standard (Key Commercial Data) | IEC 60947-7-3 |
| Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data) | >32 % |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Maximum load current (upper level) (Key Commercial Data) | 6.3 A (the current is determined by the fuse used) |
| Shock protection test specification (Key Commercial Data) | DIN EN 50274 (VDE 0660-514):2002-11 |
| Flame test method (DIN EN 60695-11-10) (Key Commercial Data) | V0 |
| Flammability rating according to UL 94 (Key Commercial Data) | V0 |
| Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data) | passed |
| Oscillation, broadband noise test result (Key Commercial Data) | Test passed |
| Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data) | passed |
| Static insulating material application in cold (Key Commercial Data) | -60 °C |
| Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data) | Test passed |
| Maximum power dissipation for nominal condition (Key Commercial Data) | 1.02 W |
| Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data) | 28 MJ/kg |
| Test specification, oscillation, broadband noise (Key Commercial Data) | DIN EN 50155 (VDE 0115-200):2008-03 |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data) | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data) | HL 1 - HL 3 |
| Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data) | passed |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 4 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 0.25 mm² |
| Relative insulation material temperature index (Elec., UL 746 B) (Key Commercial Data) | 130 °C |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 4 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 0.25 mm² |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data) | 130 °C |