| Parameter | Value |
|---|---|
| Machine building | |
| note | Observe the permissible current load of the mounting rails. |
| Color | grey (RAL 7042) |
| Depth | 64.3 mm |
| Scope | Railway industry |
| width | 3.5 mm |
| Result | Test passed |
| height | 119.5 mm |
| Spectrum | Electrical Life Check Category 1, Class B, Body Mounted |
| ASD Level | 0.964 (m/s²)²/Hz |
| Frequency | f1= 5 Hz a f2= 150 Hz |
| Gauge Pad | A1 / B1 |
| Shock Form | Semi-sinusoidal |
| Acceleration | 0.58g |
| Product Type | Clamp for earth conductors |
| Mounting type | NS 35/7.5 |
| Rated current | 15 A (take into account derating) |
| Article review | 00 |
| Number of rows | 3 |
| Open side wall | Yes |
| Product Family | PTS |
| Shock Duration | 30 ms |
| Nominal voltage | 500 V |
| Test Directions | X, Y, and Z axis |
| Depth on NS 35/15 | 65.8 mm |
| Depth on NS 35/7.5 | 58.3 mm |
| Test Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Degree of pollution | 3 |
| Insulation material | PA |
| Maximum load current | 15 A |
| Overvoltage Category | Iii |
| Ground Conductor Foot | Yes |
| Nominal cross-section | 1.5 mm² |
| Number of connections | 6 |
| Sizing Impulse Voltage | 6 kV |
| Test duration per axle | 5 h |
| Test force rated value | 1 N |
| Duration of application | 30 s |
| Test voltage rated value | 7.3 kV |
| Insulation Material Group | The |
| Thickness of the end plate | 0.8 mm |
| Conductor cross-section AWG | 26 ... 16 (converted according to IEC) |
| Support rail/fixing support | NS 35 |
| Rigid conductor cross-section | 0.14 mm² ... 1.5 mm² |
| Standard-compliant connection | IEC 60947-7-1/IEC 60947-7-2 |
| Ambient temperature (mounting) | -5 °C ... 70 °C |
| Number of connections per plan | 2 |
| Number of shocks per direction | 3 |
| Ambient temperature (operating) | -60 °C (for maximum operating temperature see derating curve) |
| Ambient Temperature (Activation) | -5 °C ... 70 °C |
| Flexible conductor cross-section | 0.14 mm² ... 1.5 mm² |
| Permissible humidity (operation) | 20 % ... 90 % |
| NFPA 130 Fume Toxicity (SMP 800C) | Exceeded |
| Length of the section to be stripped | 8 mm ... 10 mm |
| Cold static insulation material insert | -60 °C |
| Flexible conductor cross-section [AWG] | 26 ... 16 (converted according to IEC) |
| Short-term current resistance 1.5 mm² | 0.18 kA |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for short duration, no longer than 24 h, -60 °C to +70 °C) |
| Combustibility class according to UL 94 | V0 |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Surface Flammability NFPA 130 (ASTM E 162) | Exceeded |
| Maximum power dissipation under nominal conditions | 0.56 W |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| NFPA 130 (ASTM E 662) Specific Optical Density of Fumes | Exceeded |
| Flexible conductor cross-section (plastic lug and collar) | 0.14 mm² ... 1 mm² is recommended for use with the AI-S 1-8 TQ mounted cable lug, art. no. 1200293 |
| Heat development calorimetric cone NFPA 130 (ASTM E 1354) | 28 MJ/kg |
| Insulation Material Relative Temperature Index (Elec., UL 746 B) | 130 °C |
| Flexible conductor cross-section (cable lug without insulation collar) | 0.14 mm² ... 1.5 mm² |
| Temperature index for insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |