| Parameter | Value |
|---|---|
| Machine building | |
| Color | blue (RAL 5015) |
| Width | 25 mm |
| Height | 105.5 mm |
| Result | Test passed |
| output | (Permanent) |
| Spectrum | Service life test category 2, bogie-mounted |
| ASD level | 6.12 (m/s²)²/Hz |
| Frequency | f1= 5 Hz to f2= 250 Hz |
| Potentials | 1 |
| Bridge data | 144 A / 50 mm² |
| Pulse shape | Half-sine |
| Revolutions | 135 |
| Acceleration | 3.12g |
| Product type | High current terminal block |
| Mounting type | NS 35/15 |
| Rated current | 215 A |
| Rated voltage | 1100 V |
| Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
| Ferrule length | 40 mm |
| Identification | II 2 GD Ex eb IIC Gb |
| Number of rows | 1 |
| Rotation speed | 10 rpm |
| Shock duration | 18 ms |
| List of bridges | Insertion bridge / EB 2-25/PT / 3260157 |
| Nominal current | 232 A |
| Nominal voltage | 1000 V |
| Open side panel | No |
| Test directions | X-, Y- and Z-axis |
| Article revision | 14 |
| Stripping length | 40 mm |
| Time of exposure | 30 s |
| Cross section AWG | 2 ... 3/0 (converted acc. to IEC) |
| Contact resistance | 0.1 mΩ |
| Depth on NS 35/15 | 108.7 mm |
| Temperature cycles | 192 |
| Area of application | Railway industry |
| Degree of pollution | 3 |
| Insulating material | PA |
| Number of positions | 1 |
| Rated surge voltage | 8 kV |
| Test force setpoint | 15 N |
| Maximum load current | 232 A (with 95 mm² conductor cross section) |
| Overvoltage category | III |
| Nominal cross section | 95 mm² |
| Number of connections | 2 |
| Test voltage setpoint | 9.8 kV |
| Test duration per axis | 5 h |
| Connection capacity AWG | 4 ... 4/0 |
| DIN rail/fixing support | NS 35/15 |
| Ex temperature increase | 40 K (237 A / 95 mm²) |
| Rated cross section AWG | 4/0 |
| Ex-certified accessories | 1206612 SZF 3-1,0X5,5 |
| Rated insulation voltage | 1000 V |
| for bridging with bridge | 1100 V |
| Connection capacity rigid | 25 mm² ... 95 mm² |
| Insulating material group | I |
| Operating temperature range | -60 °C ... 110 °C |
| Conductor cross section rigid | 25 mm² ... 95 mm² |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Conductor cross section/weight | 25 mm² / 4.5 kg |
| Number of shocks per direction | 3 |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Number of connections per level | 2 |
| Conductor cross section flexible | 25 mm² ... 95 mm² |
| Connection in acc. with standard | IEC 60947-7-1 |
| Permissible humidity (operation) | 20 % ... 90 % |
| Requirement temperature-rise test | Increase in temperature ≤ 45 K |
| at bridging with insertion bridge | 1100 V |
| Short-time withstand current 95 mm² | 11.4 kA |
| Flammability rating according to UL 94 | V0 |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Conductor cross section, flexible [AWG] | 2 ... 3/0 (converted acc. to IEC) |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Cross-section with insertion bridge, rigid | 70 mm² |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Cross-section with insertion bridge, flexible | 70 mm² |
| Static insulating material application in cold | -60 °C |
| Maximum power dissipation for nominal condition | 7.54 W |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Flexible conductor cross section (ferrule with plastic sleeve) | 25 mm² ... 95 mm² |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 25 mm² ... 95 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 95 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 25 mm² |
| Single conductor/terminal point, flexible, with ferrule, without plastic sleeve, AWG | 4 ... 4/0 |
Technical specifications and performance data