Service time: Monday to Friday 9:00-18:00
PTI 2,5-LO/LO - PTI 2,5-LO/LO 3213944 PHOENIX CONTACT Installation level terminal block
In Stock Hot Product

PTI 2,5-LO/LO

PTI 2,5-LO/LO 3213944 PHOENIX CONTACT Installation level terminal block

$0.00USD
3091 in stock
Key Specifications
:6 kV
Color:gray (RAL 7042)
Depth:48.6 mm
Width:5.2 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
6 kV
Colorgray (RAL 7042)
Depth48.6 mm
Width5.2 mm
Height101 mm
ResultTest passed
SpectrumService life test category 1, class B, body mounted
ASD level0.964 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 150 Hz
Potentials2
Pulse shapeHalf-sine
Revolutions135
Acceleration0.58g
Product typeInstallation terminal block
Mounting typeNS 35/7,5
SpecificationDIN EN 50155 (VDE 0115-200):2008-03
Number of rows3
Rotation speed10 rpm
Shock duration30 ms
End cover width2.2 mm
Nominal current24 A (with 4 mm² conductor cross section)
Nominal voltage400 V (phase conductor/phase conductor)
Open side panelYes
Test directionsX-, Y- and Z-axis
Article revision06
Service Entranceyes
Stripping length10 mm
Time of exposure30 s
Cross section AWG26 ... 12 (converted acc. to IEC)
Depth on NS 35/1558 mm
Temperature cycles192
Degree of pollution3
Depth on NS 35/7,550.5 mm
Insulating materialPA
Rated surge voltage4 kV
Test force setpoint1 N
Maximum load current30 A (with 4 mm² conductor cross section and 3-pos. terminal block)
Overvoltage categoryIII
Nominal cross section2.5 mm²
Number of connections4
Test voltage setpoint7.3 kV
Test duration per axis5 h
DIN rail/fixing supportNS 35
Insulating material groupI
Internal cylindrical gageA3
Conductor cross section rigid0.14 mm² ... 4 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Conductor cross section/weight0.14 mm² / 0.2 kg
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level2
Conductor cross section flexible0.14 mm² ... 4 mm²
Permissible humidity (operation)20 % ... 90 %
Requirement temperature-rise testIncrease in temperature ≤ 45 K
Short-time withstand current 4 mm²0.48 kA
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Conductor cross section, flexible [AWG]26 ... 12 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition1.02 W
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm²

Product Description

Distribution floor terminal block, without actuation latch on the power side, nominal voltage: 400 V, nominal current: 24 A, Push-in connection, 1., 2. and 3rd floor, Dimensioning cross-section: 4 mm²
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top