ParameterValue
GTIN4055626665849
Orderkey1047479
(Drawings)
Catalog pagePage 436 (C-1-2019)
Packing unit1 pc
Width (General)19 mm
Color (Drawings)blue
Height (General)18.7 mm
Length (General)21.6 mm
Country of originPL (Poland)
ETIM 5.0 (eCl@ss)EC000897
ETIM 6.0 (eCl@ss)EC000897
ETIM 7.0 (eCl@ss)EC000897
(Connection data)IEC 60998-2-2
ASD level (Drawings)6.12 (m/s2)2/Hz
Custom tariff number85369010
Shock form (Drawings)Half-sine
Minimum order quantity20 pc
Acceleration (Drawings)30g
Connection (Dimensions)Feed-in stage
Test spectrum (Drawings)Service life test category 2, bogie-mounted
Shock duration (Drawings)18 ms
Test frequency (Drawings)f1= 5 Hz to f2= 250 Hz
Open side panel (Drawings)No
Test directions (Drawings)X-, Y- and Z-axis (pos. and neg.)
Number of levels (Drawings)1
Shock test result (Drawings)Test passed
eCl@ss 8.0 (Classifications)27141120
eCl@ss 9.0 (Classifications)27141120
Nominal current IN (Drawings)41 A
Nominal voltage UN (Drawings)500 V
Stripping length (Dimensions)10 mm ... 12 mm
Connection method (Dimensions)Push-in connection
Degree of pollution (Drawings)3
Insulating material (Drawings)PA
Rated surge voltage (Drawings)6 kV
Maximum load current (Drawings)41 A (with 6 mm² conductor connection)
Overvoltage category (Drawings)III
Maximum total current (Drawings)41 A
Nominal cross section (Drawings)1.5 mm²
Number of connections (Drawings)7
Result of thermal test (Drawings)Test passed
Test duration per axis (Drawings)5 h
Insulating material group (Drawings)I
Weight per Piece (excluding packing)0.000 g
Internal cylindrical gage (Dimensions)A3
Nominal cross section feed-in (Drawings)6 mm²
NF F16-101, NF F10-102 Class F (Drawings)2
NF F16-101, NF F10-102 Class I (Drawings)2
Number of shocks per direction (Drawings)3
Test specification, shock test (Drawings)DIN EN 50155 (VDE 0115-200):2018-05
Oxygen index (DIN EN ISO 4589-2) (Drawings)>32 %
Conductor cross section AWG max. (Dimensions)10
Conductor cross section AWG min. (Dimensions)24
Connection in acc. with standard (Dimensions)IEC 60998-2-2
Conductor cross section solid max. (Dimensions)6 mm²
Conductor cross section solid min. (Dimensions)0.2 mm²
Flame test method (DIN EN 60695-11-10) (Drawings)V0
Flammability rating according to UL 94 (Drawings)V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Drawings)passed
Conductor cross section flexible max. (Dimensions)4 mm²
Conductor cross section flexible min. (Dimensions)0.2 mm²
Connection in acc. with standard (Connection data)IEC 60998-2-2
Oscillation, broadband noise test result (Drawings)Test passed
Surface flammability NFPA 130 (ASTM E 162) (Drawings)passed
Max. AWG conductor cross section, flexible (Dimensions)10
Min. AWG conductor cross section, flexible (Dimensions)24
Flammability rating according to UL 94 (Connection data)V0
Static insulating material application in cold (Drawings)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Drawings)Test passed
Calorimetric heat release NFPA 130 (ASTM E 1354) (Drawings)27,5 MJ/kg
Test specification, oscillation, broadband noise (Drawings)DIN EN 50155 (VDE 0115-200):2018-05
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Drawings)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Drawings)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Drawings)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Drawings)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Drawings)passed
Relative insulation material temperature index (Elec., UL 746 B) (Drawings)130 °C
Proof of thermal characteristics (needle flame) effective duration (Drawings)30 s
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Drawings)125 °C
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions)4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions)0.2 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions)4 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions)0.2 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions)1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. (Dimensions)0.5 mm²

Product Description

Distribution block, nominal voltage: 450 V, nominal current: 17.5 A, number of connections: 7, connection type: Push-in connection, Branch, cross-section: 0.14 mm² - 2.5 mm², Collective connection, Di
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Circuit diagram

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top