| Parameter | Value |
|---|---|
| GTIN | 4055626665696 |
| Orderkey | 1047464 |
| (Drawings) | |
| Catalog page | Page 437 (C-1-2019) |
| Packing unit | 1 pc |
| Width (General) | 21.6 mm |
| Color (Drawings) | pink |
| Length (General) | 58.1 mm |
| Country of origin | PL (Poland) |
| ETIM 5.0 (eCl@ss) | EC000897 |
| ETIM 6.0 (eCl@ss) | EC000897 |
| ETIM 7.0 (eCl@ss) | EC000897 |
| (Connection data) | IEC 60998-2-2 |
| Custom tariff number | 85369010 |
| Height NS 15 (General) | 26.4 mm |
| Minimum order quantity | 20 pc |
| Connection (Dimensions) | Feed-in stage |
| Height NS 35/7,5 (General) | 28.4 mm |
| Open side panel (Drawings) | No |
| Number of levels (Drawings) | 1 |
| eCl@ss 6.0 (Classifications) | 27141100 |
| eCl@ss 7.0 (Classifications) | 27141120 |
| eCl@ss 8.0 (Classifications) | 27141120 |
| eCl@ss 9.0 (Classifications) | 27141120 |
| Nominal current IN (Drawings) | 41 A |
| Nominal voltage UN (Drawings) | 500 V |
| Stripping length (Dimensions) | 10 mm ... 12 mm |
| Connection method (Dimensions) | Push-in connection |
| Degree of pollution (Drawings) | 3 |
| Insulating material (Drawings) | PA |
| Rated surge voltage (Drawings) | 6 kV |
| Maximum load current (Drawings) | 41 A (with 6 mm² conductor cross section) |
| Overvoltage category (Drawings) | III |
| Maximum total current (Drawings) | 41 A |
| Nominal cross section (Drawings) | 1.5 mm² |
| Number of connections (Drawings) | 19 |
| Insulating material group (Drawings) | I |
| Weight per Piece (excluding packing) | 23.000 g |
| Internal cylindrical gage (Dimensions) | A3 |
| Nominal cross section feed-in (Drawings) | 4 mm² |
| Conductor cross section AWG max. (Dimensions) | 10 |
| Conductor cross section AWG min. (Dimensions) | 24 |
| Connection in acc. with standard (Dimensions) | IEC 60998-2-2 |
| Conductor cross section solid max. (Dimensions) | 6 mm² |
| Conductor cross section solid min. (Dimensions) | 0.2 mm² |
| Flammability rating according to UL 94 (Drawings) | V0 |
| Conductor cross section flexible max. (Dimensions) | 4 mm² |
| Conductor cross section flexible min. (Dimensions) | 0.2 mm² |
| Connection in acc. with standard (Connection data) | IEC 60947-7-1 |
| Max. AWG conductor cross section, flexible (Dimensions) | 10 |
| Min. AWG conductor cross section, flexible (Dimensions) | 24 |
| Flammability rating according to UL 94 (Connection data) | V0 |
| Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions) | 4 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions) | 0.2 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions) | 4 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions) | 0.2 mm² |
Technical specifications and performance data