Service time: Monday to Friday 9:00-18:00
PTB 2,5-PE/L/NTG - PTB 2,5-PE/L/NTG 3210545 PHOENIX CONTACT Installation ground terminal block
In Stock Hot Product

PTB 2,5-PE/L/NTG

PTB 2,5-PE/L/NTG 3210545 PHOENIX CONTACT Installation ground terminal block

$5.11USD
1996 in stock
Key Specifications
GTIN:4046356693875
Orderkey:3210545
Catalog page:Page 89 (C-1-2017)
Packing unit:50 pc
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356693875
Orderkey3210545
Catalog pagePage 89 (C-1-2017)
Packing unit50 pc
Width (General)5.2 mm
Length (General)118 mm
Country of originPL (Poland)
Note (Dimensions)Please observe the current carrying capacity of the DIN rails.
Custom tariff number85369010
(Key Commercial Data)4 mm² / 0.9 kg
Minimum order quantity50 pc
Height NS 35/15 (General)49.8 mm
Height NS 35/7,5 (General)42.3 mm
Color (Key Commercial Data)gray
(Standards and Regulations)No hazardous substances above threshold values
Stripping length (Dimensions)8 mm ... 10 mm
Connection method (Dimensions)Push-in connection
Setpoint (Key Commercial Data)1 N
ASD level (Key Commercial Data)6.12 (m/s2)2/Hz
Shock form (Key Commercial Data)Half-sine
Acceleration (Key Commercial Data)30g
Test spectrum (Key Commercial Data)Service life test category 2, bogie-mounted
Shock duration (Key Commercial Data)18 ms
Test frequency (Key Commercial Data)f1= 5 Hz to f2= 250 Hz
Weight per Piece (excluding packing)21.500 g
Open side panel (Key Commercial Data)Yes
Test directions (Key Commercial Data)X-, Y- and Z-axis (pos. and neg.)
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Internal cylindrical gage (Dimensions)A3
Number of levels (Key Commercial Data)3
Finger protection (Key Commercial Data)guaranteed
Shock test result (Key Commercial Data)Test passed
Bending test turns (Key Commercial Data)135
Nominal current IN (Key Commercial Data)22 A (with a 2.5 mm² conductor cross section)
Nominal voltage UN (Key Commercial Data)250 V
Short-time current (Key Commercial Data)0.18 kA
Degree of pollution (Key Commercial Data)3
Insulating material (Key Commercial Data)PA
Rated surge voltage (Key Commercial Data)4 kV
Tensile test result (Key Commercial Data)Test passed
Maximum load current (Key Commercial Data)30 A (with 4 mm² conductor cross section and 3-pos. terminal block)
Overvoltage category (Key Commercial Data)III
Result of aging test (Key Commercial Data)Test passed
Tight fit on carrier (Key Commercial Data)NS 35
Nominal cross section (Key Commercial Data)2.5 mm²
Number of connections (Key Commercial Data)5
Result of bending test (Key Commercial Data)Test passed
Result of thermal test (Key Commercial Data)Test passed
Test duration per axis (Key Commercial Data)5 h
Conductor cross section AWG max. (Dimensions)12
Conductor cross section AWG min. (Dimensions)26
Tractive force setpoint (Key Commercial Data)60 N
Conductor cross section solid max. (Dimensions)4 mm²
Conductor cross section solid min. (Dimensions)0.14 mm²
Insulating material group (Key Commercial Data)I
Requirements, voltage drop (Key Commercial Data)≤ 3.2 mV
Back of the hand protection (Key Commercial Data)guaranteed
Bending test rotation speed (Key Commercial Data)10 rpm
Result of voltage-drop test (Key Commercial Data)Test passed
Surge voltage test setpoint (Key Commercial Data)7.3 kV
Conductor cross section flexible max. (Dimensions)4 mm²
Conductor cross section flexible min. (Dimensions)0.14 mm²
Result of surge voltage test (Key Commercial Data)Test passed
NF F16-101, NF F10-102 Class F (Key Commercial Data)2
NF F16-101, NF F10-102 Class I (Key Commercial Data)2
Number of shocks per direction (Key Commercial Data)3
Result of tight fit on support (Key Commercial Data)Test passed
Short circuit stability result (Key Commercial Data)Test passed
Test specification, shock test (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Nominal current IN(upper level) (Key Commercial Data)16 A (with a 2.5 mm² conductor cross section)
Result of temperature-rise test (Key Commercial Data)Test passed
Oxygen index (DIN EN ISO 4589-2) (Key Commercial Data)>32 %
Flammability rating according to UL 94 (Connection data)V0
Maximum load current (upper level) (Key Commercial Data)16 A (with 4 mm² conductor cross section)
Shock protection test specification (Key Commercial Data)DIN EN 50274 (VDE 0660-514):2002-11
Conductor cross section tensile test (Key Commercial Data)4 mm²
Flame test method (DIN EN 60695-11-10) (Key Commercial Data)V0
Flammability rating according to UL 94 (Key Commercial Data)V0
Smoke gas toxicity NFPA 130 (SMP 800C) (Key Commercial Data)passed
Oscillation, broadband noise test result (Key Commercial Data)Test passed
Power frequency withstand voltage setpoint (Key Commercial Data)1.89 kV
Surface flammability NFPA 130 (ASTM E 162) (Key Commercial Data)passed
Bending test conductor cross section/weight (Key Commercial Data)0.14 mm² / 0.2 kg
Conductor cross section short circuit testing (Key Commercial Data)2.5 mm²
Static insulating material application in cold (Key Commercial Data)-60 °C
Behavior in fire for rail vehicles (DIN 5510-2) (Key Commercial Data)Test passed
Maximum power dissipation for nominal condition (Key Commercial Data)0.77 W (the value is multiplied when connecting multiple levels)
Calorimetric heat release NFPA 130 (ASTM E 1354) (Key Commercial Data)28 MJ/kg
Result of power-frequency withstand voltage test (Key Commercial Data)Test passed
Test specification, oscillation, broadband noise (Key Commercial Data)DIN EN 50155 (VDE 0115-200):2008-03
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Connection data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R22 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 (Key Commercial Data)HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 (Key Commercial Data)HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662) (Key Commercial Data)passed
Conductor cross section flexible, with ferrule with plastic sleeve max. (Dimensions)2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min. (Dimensions)0.14 mm²
Relative insulation material temperature index (Elec.; UL 746 B) (Key Commercial Data)130 °C
Conductor cross section flexible, with ferrule without plastic sleeve max. (Dimensions)2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve min. (Dimensions)0.14 mm²
Proof of thermal characteristics (needle flame) effective duration (Key Commercial Data)30 s
Ageing test for screwless modular terminal block temperature cycles (Key Commercial Data)192
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) (Key Commercial Data)130 °C
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. (Dimensions)0.5 mm²
Checking the mechanical stability of terminal points (5 x conductor connection) (Key Commercial Data)Test passed

Product Description

Ground terminal for distribution, nominal voltage: 400 V, nominal current: 22 A, Push-in connection, Dimensioning cross-section: 2.5 mm², cross-section: 0.14 mm² - 4 mm², Push-in connection, Dimension
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty