| Parameter | Value |
|---|---|
| You can check the rated current and the maximum load current on the rating curve. | |
| Depth | 63.1 mm |
| Width | 10.2 mm |
| Colour | grey (RAL 7042) |
| Height | 91 mm |
| Result | Approved Test |
| Spectrum | Category 2 durability test, on the bogie |
| ASD Level | 6.12 (m/s²)²/Hz |
| Potential | 1 |
| Rotations | 135 |
| frequency | f1= 5 Hz to f2= 250 Hz |
| Male Gauge | A5 |
| Shock Type | Semi-sinusoid |
| Observation | In the overhead connection, the user must ensure that the necessary sections to surfaces that conduct electricity are met. |
| Peel Length | 10 mm ... 12 mm |
| Plug Cycles | 250 |
| Acceleration | 3.12g |
| Product Type | Sectional terminal block |
| Open sidewall | No |
| Article Review | 03 |
| Depth in NS 32 | 69.3 mm |
| Number of rows | 1 |
| Product Family | PT |
| Rotation speed | 10 r.p.m. |
| Surge Category | Iii |
| Nominal Section | 6 mm² |
| Nominal current | 32 A |
| Nominal voltage | 1000 V |
| Test Directions | X, Y, and Z axes |
| Performance Time | 30 sec |
| Type of mounting | NS 35/7.5 |
| Depth at NS 35/15 | 71.8 mm |
| Depth at NS 35/7.5 | 64.3 mm |
| Temperature Cycles | 192 |
| Test Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Degree of pollution | 3 |
| Insulating material | PA |
| Rail/Fixing Surface | NS 32/NS 35 |
| AWG Conductor Section | 20 ... 8 (Converted according to IEC) |
| Duration of the crash | 18 ms |
| Number of connections | 2 |
| Test duration per axis | 5 h |
| Rigid conductor section | 0.5 mm² ... 10 mm² |
| Conductor Section/Weight | 0.5 mm2/0.3 kg |
| Heating test requirement | Temperature rise ≤ 45 K |
| Maximum Charging Current | 32 A (with rigid 10 mm² cable cross-section) |
| Nominal Value Test Force | 5 N |
| Insulating material group | I |
| Flexible conductor section | 0.5 mm² ... 10 mm² |
| Test Voltage Nominal Value | 9.8 kV |
| Ambient Temperature (Drive) | -5 °C ... 70 °C |
| Flexible Wire Section [AWG] | 20 ... 8 (Converted according to IEC) |
| Ambient Temperature (Service) | -60 °C ... 110 °C (Operating temperature range incl. self-heating, max. short-term operating temperature; see RTI Elec.) |
| Standard-compliant connection | IEC 60947-7-1 |
| Ambient Temperature (Mounting) | -5 °C ... 70 °C |
| Dimensioning Transient Voltage | 8 kV |
| Number of connections per floor | 2 |
| Number of collisions per steering | 3 |
| Permissible air humidity (service) | 20 % ... 90 % |
| Flammability class according to UL 94 | V0 |
| NFPA 130 Flue Gas Toxicity (SMP 800C) | approved |
| Permissible short-term current 4 mm² | 0.48 kA |
| Static use of cold insulating material | -60 °C |
| Ambient Temperature (Storage/Transport) | -25 °C ... 60 °C (for a short time, no more than 24 hours, -60 °C to +70 °C) |
| Permissible air humidity (storage/transport) | 30 % ... 70 % |
| Flammability of NFPA 130 Surfaces (ASTM E 162) | approved |
| Maximum Dissipated Power with Nominal Condition | 1.31 W |
| Heat Emission Calorimeter NFPA 130 (ASTM E 1354) | 28 MJ/kg |
| Flexible cable section (toe cap with plastic sleeve) | 0.5 mm² ... 10 mm² |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Flexible cable section (toe cap without plastic sleeve) | 0.5 mm² ... 10 mm² |
| NFPA 130 Specific Optical Flue Gas Density (ASTM E 662) | approved |
| Relative Insulating Material Temperature Index (Elec., UL 746 B) | 130 °C |
| 2 conductors with the same cross-section, flexible with TWIN toe cap with plastic sleeve | 0.5 mm² ... 2.5 mm² If TWIN bushings are used, we recommend a minimum standard bushing length of 13 mm. |
Technical specifications and performance data