Service time: Monday to Friday 9:00-18:00
PT 4-PE/3L - PT 4-PE/3L 3210442 PHOENIX CONTACT Motor terminal
In Stock Hot Product

PT 4-PE/3L

PT 4-PE/3L 3210442 PHOENIX CONTACT Motor terminal

$0.00USD
3331 in stock
Key Specifications
:4 mm² / 0.9 kg
Note:Please observe the current carrying capacity of the DIN rails.
Color:gray (RAL 7042)
Depth:95.4 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
4 mm² / 0.9 kg
NotePlease observe the current carrying capacity of the DIN rails.
Colorgray (RAL 7042)
Depth95.4 mm
Width6.2 mm
Height104.4 mm
ResultTest passed
SpectrumService life test category 2, bogie-mounted
ASD level6.12 (m/s²)²/Hz
Frequencyf1= 5 Hz to f2= 250 Hz
Potentials4
Pulse shapeHalf-sine
Revolutions135
Acceleration3.12g
Product typeMotor terminal block
Mounting typeNS 35/7,5
SpecificationDIN EN 50155 (VDE 0115-200):2008-03
Grounding footYes
Number of rows4
Rotation speed10 rpm
Shock duration18 ms
End cover width2.2 mm
Nominal current26 A (with 4 mm² conductor cross section)
Nominal voltage800 V
Open side panelYes
Test directionsX-, Y- and Z-axis
Article revision01
Stripping length10 mm ... 12 mm
Time of exposure30 s
Cross section AWG24 ... 10 (converted acc. to IEC)
Depth on NS 35/15104.4 mm
Temperature cycles192
Degree of pollution3
Depth on NS 35/7,596.9 mm
Insulating materialPA
Rated surge voltage6 kV
Test force setpoint1 N
Maximum load current32 A (with 6 mm² conductor cross section, rigid)
Overvoltage categoryIII
Nominal cross section4 mm²
Number of connections7
Test voltage setpoint9.8 kV
Test duration per axis5 h
DIN rail/fixing supportNS 35
Insulating material groupI
Internal cylindrical gageA4
Conductor cross section rigid0.2 mm² ... 6 mm²
Ambient temperature (assembly)-5 °C ... 70 °C
Conductor cross section/weight0.2 mm² / 0.2 kg
Number of shocks per direction3
Ambient temperature (actuation)-5 °C ... 70 °C
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Number of connections per level2
Conductor cross section flexible0.2 mm² ... 6 mm²
Connection in acc. with standardIEC 60947-7-1/IEC 60947-7-2
Permissible humidity (operation)20 % ... 90 %
Requirement temperature-rise testIncrease in temperature ≤ 45 K
Short-time withstand current 4 mm²0.48 kA
Short-time withstand current 6 mm²0.72 kA
Flammability rating according to UL 94V0
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Conductor cross section, flexible [AWG]24 ... 10 (converted acc. to IEC)
Permissible humidity (storage/transport)30 % ... 70 %
Surface flammability NFPA 130 (ASTM E 162)passed
Static insulating material application in cold-60 °C
Maximum power dissipation for nominal condition1.02 W
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Flexible conductor cross section (ferrule with plastic sleeve)0.25 mm² ... 4 mm²
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Conductor cross-section flexible (ferrule without plastic sleeve)0.25 mm² ... 4 mm²
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm² ... 1 mm²

Product Description

Motor terminal block, four-tier, connection type: push-in connection, cross-section: 0.2 mm² - 6 mm², AWG: 24 - 10, width: 6.2 mm, height: 95.4 mm, colour: grey, mounting type: NS 35/7.5, NS 35/15
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top